SAFETY CONSIDERATIONS

  • Unauthorized repair are prohibited, it may cause serious incident
  •  Keep the device dry, do NOT use in rain or snow
  • Make sure lid of feeding hopper are well covered when use SPARKULAR JET. Accidentally burning of Composite Ti can only use sands to extinguish. Composite Ti should keep away from moisture and stored in a dry sealed environment
  • Keep audience, animals or flammable objects at a minimum distance of 3m from SPARKULAR JET. Make sure sparks shoot out from SPARKULAR JET can NOT touch any objects in the air
  • Please be noted that there may sparks or remains fall to the ground. Make sure there is no flammable objects such as carpet on the ground (with a radius of 3m close to the machine)
  • Never touch the nozzle of SPARKULAR JET, danger of getting burnt
  • Never touch the sparks which shooting out from the nozzle
  • Cover of nozzle of SPARKULAR JET is prohibited
  • For better heat dissipation, block the air intake and air outlet is prohibited

Description

SPARKULAR JET is another brand new effect originally invented by SHOWVEN. It generates a flashing SPARKULAR effect up to 10m. Built-in automatic air compressor, no external pressure tank needed, makes it easier for setup and fewer usage restrictions. It is perfect effects solution for stadium, concerts etc. medium to large events

Technical Specifications

  • Dimension: 320 280 300mm
  • Weight: 16.5kg
  • Housing material: 304 Stainless steel
  • Input: AC 100V-120V,50/60Hz, Max.cascade:3PCS AC 200V-240V,50/60Hz, Max.cascade:6PCS
  • Work power: 350W
  • Work Temp.: -10 ~50
  • Effect height: HC8200 LARGE(8-10m) / HC8200 MEDIUM(6-8m) / SMALL(4-5m)
  • Hopper capacity: 450g
  • HC8200 consumption: HC8200 LARGE/MEDIUM 10-15g/shot; HC8200 SMALL 4-6g/shot
  • Interface: 3-pin and 5-pin DMX IN/OUT, NEUTRIK POWERCON TURE 1
  • Control: Standard DMX, 2 Channels

Operation Panel

  1. LED display area:**Showven Technologies Co Ltd HC8200 Sparkular Jet - display
    READY: Green light flashing means heating up. Turns from flashing into long on, indicates that the machine is ready to work
    DMX: Flashing shows that DMX signal is connected, light OFF means there is no DMX signal
    FAULT: Light ON when error occurs
    HEAT: Light ON when system is heating up
    **

  2. Control button area:
    Showven Technologies Co Ltd HC8200 Sparkular Jet - Control
button
    MENU:
    switch through setup menu. Press 3s switch to advanced interface
    DOWN: parameter down
    UP: parameter up
    ENTER: confirm and save parameters

  3. RFID area:
    Showven Technologies Co Ltd HC8200 Sparkular Jet - RFID
area

RFID card comes together with HC8200. It is a safety design, allows machine to identify the parameter and types of consumable
Please note that granules RFID card can increase the single machine specific working time. The card is disposable, can only use once

Interface

  1. Main Interface:**Showven Technologies Co Ltd HC8200 Sparkular Jet - Main Interface
    First Line: DMX address, current pressure value
    Second Line: inner core temp. delayed firing time
    The working principle of the machine is when the firing is triggered, it takes some time (jet delay) for the system to transfer and stimulate the consumables. When it reached the delayed firing time, the valve will open automatically and firing activated

    **

  2. Error information:
    Error information| Explanation
    ---|---
    **** E0 System IC| 1.Emergency stop was executed when firing was triggered, and firing stops. E0 disappear automatically 1min later
    2. Too frequent firing in a short period of time, E0 disappear 100s later
    E1 Pump Protect| It happens when continuous pressurization fail, probably the pump was malfunction
    E2 Temp. Sensor| Temperature sensor is not connected or damage
    E3 P Temp. Over| Chassis over-temperature
    E4 Time Remain| Activated time for machine is not enough, need to swap RFID card
    E5 K Temp. Over| Inner core over-temperature
    E6 Heat Fail| Heating fail, if recover automatically, please pay attention to the power supply

  3. Setting Menu:
    Press “MENU” switch through setup menu.

Options Range Explanation

Set DMX Address

|

1-512

| Set DMX address. If controlled by Host Controller, please set DMX address as 1, 3, 5, 7,…2n-1, otherwise it may leads to signal interference

Set Pressure

|

15-45

| Adjust the pressure value, the higher the pressure, the higher the effect; After change the pressure please make a manual clear to reset the pressure inside machine.
Manual Clear| On/Off| Manual clear material. Please be careful, do NOT close to the nozzle
4. Advanced Menu:
Press “MENU” switch through setup menu. Options| Range| Explanation
---|---|---
Set Temperature| 580-620| Set inner core temp
Auto Heat| On/Off| Auto heat ON/OFF when switch on machine
Jet Delay| 0.5-2.0s| Firing delay set, time delay between press firing on DMX/controller (firing trigger) and actual sparks out from the nozzle
Mode Selection| Factory Mode/ User Mode| Factory mode is for engineer only. When in Factory mode machine can’t controlled by DMX console/host controller
Standby Switch| On/Off| Standby function. When ON, the machine can firing only when heating up was finished
Ext. Ignite| On/Off| When use fireworks firing system to firing the machine. Customized design for fireworks customer
Feeding Test| On/Off| Test the feeding structure and feeding motor
Fan Test| On/Off| Test the blowing fan
Feeding1 Time| 0.1-0.3s| Feeding time of the HC8200 from the hopper
Feeding2 Time| 0.5-3.0| Working time of shaft motor, Feeding2 time should shorter than Jet Delay time

*Please don’t change default value without engineer’s suggestion from SHOWVEN

  1. DMX channel – 2 channel mode:
    ** First channel| Function
    ---|---
    0-111| no function
    112-255| Firing. To avoid false triggering, the trigger time should maintain above 0.2s
    Second channel| Function
    **
    60-80| Clear material, the valve will open when clear matrial, and clear the consumable remains in the pipeline. Please DO remember to clear material after each show
    **** 20-40| Emergency stop, when firing was triggered, operator can stop the firing during this jet delay period. And machine will prompt E0 error
    0-10| Pre-heat OFF (disabled when auto-heat ON)
    240-255| Pre-heat ON (disabled when auto-heat ON)
  2. When use SHOWVEN original host controller. Please follow bellowing rules to set DMX address, otherwise it may leads to signal interference. The firing duration set on host controller should be larger than 0.2s, and effect height set 5-10

Sparkular Jet No.| 1| 2| 3| 4| 5| 6| 7| 8| 9| 10| 11| 12| 13| 14| 15| 16| 17| 18
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
DMX Address| 1| 3| 5| 7| 9| 11| 13| 15| 17| 19| 21| 23| 25| 27| 29| 31| 33| 35

Warranty Instructions

  • Sincere thanks for your choosing our products, you will receive quality service from us

  • The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model
    machine for you

  • We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors)in warranty
    period. Please don’t repair machine without factory permission

Below situations NOT included in warranty service:

  1. Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
  2. Disassemble, modify or repair products without Showven’s permission;
  3. Damage caused by external reasons (lightning strike, power supply etc)
  4. Damage caused by improper installation or use;

For product damage not included in warranty range, we can provide paid service.
Invoice and warranty card are necessary when applying for maintenance service from SHOWVEN.

Warranty Card

Product Name:| | Serial No.|
---|---|---|---
Purchase Date:|
Tel:|
Address:|
Info. feedback about the problem:|
Actual problem:|
Maintenance detail:|
Service Engineer:| | Service Date:|

Showven - logohttps://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail: info@showven.cn
Add: Liuyang Economic Development Zone, Changsha, 410300, Hunan Province,
P.R.China

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals