Read This Manual
Inside you will find many helpful hints on how to use and maintain your air
conditioner properly. Just a little preventive care on your part can save you
a great deal of time and money over the life of your air conditioner. You’ll
find many answers to common problems in the chart of troubleshooting tips.If
you reviewo urc harto f T roubleshooting Tips first, you may not need to call
for service at all.
CAUTION
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not be made by children without supervision. ( be applicable for the European Countries )
- This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge, unlessthey have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. (be applicable for other countries except the European Countries )
- Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance shall be installed in accordance with national wiring regulations.
- The appliance with electric heater shall have atl east 1 meters pac e t ot he c om bustible materials.
- Contactthe authorised service technician for repair or maintenance of this unit.
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
WARNING This symbol indicates the possibility of death or serious injury.
CAUTION This symbol indicates the possibility of injury or damage to property
Meanings of symbols used in this manual are as shown below.
- Never do this.
- Always do this.
WARNING
Do not exceed the rating of the power outlet or connection device.
- Otherwise, it may cause electric shock or fire due to excess heat generation.
Do not modify power cord length or share the outlet with other appliances
- It may cause electric shock or fire due to heat generation.
Disconnect the power if strange sounds, smell, or smoke comes from it.
- It may cause fire and electric shock
Do not use the machine near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
- It may cause an explosion or fire.
CAUTION
Do not use the unit in small spaces.
- Lack of ventilation can cause overheating and fire.
Do not put in places where water may splash onto the unit.
- Water may enter the unit and degrade the insulation. It may cause an electric shock or fire.
Place the unit on a level, sturdy section of the floor
- If the unit falls over, it may cause water to spill and damage belongings, or cause electrical shock or fire.
CAUTION
Do not cover the intake or exhaust openings with cloths or towels.
- A lack of air flow can lead to overheating and fire.
Never insert your finger or other foreign objects into grills or openings. Take special care to warn children of these dangers.
- It may cause electric shock or failure of appliance.
Always insert the filters securely. Clean filter once every two weeks.
- Operation without filters may cause failure.
Be careful when you removing the filter not to damage the fins. Turn off the unit before remove the water bucket.
- It may cause failure of appliance or injure your finger
Electrical Information
- The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit.
- Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
- Ensure the receptacle is accessible after the unit installation.
- Do not use extension cords or an adapter plugs with this unit. However, if it is necessary to use an extension cord, use an approved Dehumidifier extension cord only (available at most local hardware stores).
- To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing and/or servicing.
CONTROL PADS ON THE DEHUMIDIFIER
NOTE: The control panel of the unit you purchased may be slightly different according to the models.
Control pads
When you push the button to change operation modes, the unit will make a beep
sound to indicate that it is changing modes.
-
PUMP Pad(on some models)
Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed into the unit and the continuous drain hose is removed from the unit before the pump operation is activated. When the bucket is full,the pump starts to work.Refer to the next pages for removing the collected water. Do not use this operation when the outdoor temperature O O is equel to or less than 0 C (32 F) -
COMFORT Pad(optional)
Press to activate the comfort dehumidifying operation.
NOTE: On this operation,the unit can not be set humidity level. -
FILTER Pad
The check filter feature is a reminder to clean the Air Filter for more efficient operation. The Filter light(Clean filter l ight) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the Filter pad and the light will go off. -
CONTINUE Pad
Press to activate the continuous dehumidifying operation -
TURBO Pad
Control the fan speed. Press to select either High or Normal fan speed. Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Normal. -
Timer Pad
Press to initiate the Auto start and Auto stop feature, in conjuction with the and key pads. -
Up/Down Pads
Humidity Set Control Pads
The humidity level can be set within a range of 35%RH(Relative Humidity) to 85%RH(Relative Humidity) in 5% increments. For drier air, press the pad and set to a lower percent value(%). For damper air, press the pad and set a higher percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Auto start and Auto stop time from 0.0 to 24. -
Power Pad
Press to turn the dehumidifier on and off. -
Display
Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the actual ( 5% accuracy) room % humidity level in a range of 30% RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error–Unplug the unit and plug it back in. If error repeats, call for service.
ES- Tube Temperature sensor of the evaporator error– Unplug the unit and plug it back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position — Empty the bucket and replace it in the right position.(only available for the uint with no pump feature.)
P2- Bucket is full — Empty the bucket.(only available for the unit with pump feature.)
EC- Refrigerant leakage detection– With this new technology, the display area will appear EC when the unit detects refrigerant leakage ,call for service.
E3- Unit malfunction– Unplug the unit and plug it back in. If error repeats, call for service.
Eb- Bucket is removed or not in right position– Replace the bucket in the right position.(only available for the unit with pump feature.)
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or when the bucket is
removed or not replaced in the proper position.When the setting humidity is
reached, the unit will be shut off automatically. For some models,the fan
motor will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart opertation in the first 3
minutes. This is to protect the unit. Operation will automatically start after
3 minutes.
Check filter feature
The system starts to count the time once the fan motor operates. The check
filter feature can be only activated when the accumulated operation time
achieves 250 hours or more. The Reset light(Clean filter indicator light)
flashes at one time per second, after finishing clean the air filter, press
the Filter pad and the Reset light(Clean filter indicator light) goes off.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut, it will restart with
the previous function setting automatically when the power resumes.
Setting the Timer
- When the unit is on, first press the Timer button, the Timer Off indicator light illuminates. It indicates the Auto Stop program is initiated. Press it again the Time On indecator light illuminates.It indicates the Auto Start is initiated.
- When the unit is off, first press the Timer button, the TIMER ON indicator light illuminates. It indicates the Auto Start program is initiated. Press it again the Time Off indecator light illuminates.It indicates the Auto Stop is initiated.
- Press or hold the UP or DOWN pad to change the Auto time by 0.5 hour incre- ments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.
- The selected time will register in 5 seconds and the system will automatically revert back to display the previous humidity setting
- When the Auto start & Auto stop times are set, within the same program sequence, TIMER ON OFF indicator lights illuminate identifying both ON and OFF times are now programmed.
- Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop function.
- When LED display window displays the code of P2, the Auto Start/Stop function will also be cancelled.
IDENTIFICATION OF PARTS
Front
- Control panel
- Panel
- Water bucket
- Water level window
- Handle (both sides)
Rear
- Continuous drain hose outlet
- Caster
- Power Cord and plug
- Power cord buckle (placed in the water bucket, used only when storing the unit. Installed as shown Fig.3a)
- Pump drain hose outlet(some models without)
- Air outlet grille
- Air filter
NOTE: All the pictures in the manual are for explanation purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same.
Accessories:(placed in the water bucket of the unit)
pump drain hose(1pc) (only for the unit with pump featrue)
power cord buckle(1pc)
female threaded end(1pc)(on some models)
Positioning the unit
A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.
- Do not use outdoors.
- This dehumidifer is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications.
- Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full bucket of water.
- Allow at least 20cm of air space on all sides of the unit for good air circulation (at least 40cm of air space on air outlet).
- Place the unit in an area where the temperature will not fall below 5 C(41 F). The coils can become covered with frost at temperatures below 5 C(41 F), which may reduce performance.
- Place the unit away from the clothes dryer, heater or radiator.
- Use the unit to prevent moisture damage anywhere books or valuables are stored.
- Use the dehumidifier in a basement to help prevent moisture damage.
- The dehumidifier must be operated in an enclosed area to be most effective.
- Close all doors, windows and other outside openings to the room
When using the unit
- When first using the dehumidifier, operate the unit continuously 24 hours. Make sure the plastic cover on the continuous drain hose outlet install stightly properlyso there are no leaks.
- This unit is designed to operate with a working O O O O environment between 5C/41 F and 35C/95 F.
- If the unit has been switched off and needs to be switched on again quickly, allow approximately three minutes for the correct operation to resume.
- Do not connect the dehumidifier to a multiple socket outlet, which is also being used for other electricalappliances.
- Select a suitable location, making sure you have easy access to an electrical outlet.
- Plug the unit into a electrical socket-outlet with earth connection.
- Make sure the Water bucket is correctly fitted otherwise the unit will not operate properly.
NOTE: When the water in the bucket reaches to a certain level,please be careful to move the machine to avoid it falling down.
OPERATING THE UNIT
Removing the collected water
There are three ways to remove collected water.
**Use the bucket
**
- When the unit is off,if the bucket is full, the Full indicator light will light.
- When the unit is on,if the bucket is full, the compressor and the fan turn off, and the Full indicator light will light, the digital display shows P2.
- Slowly pull out the bucket. Grip the left and right handles securely, and carefully pull out straight so water does not spill. Do not put the bucket on the floor because the bottom of the bucket is uneven. Otherwise the bucket will fall and cause the water to spill.
- Throw away the water and replace the bucket. The bucket must be in right place and securely seated for the dehumidifier to operate.
- The machine will re-start when the bucket is restored in its correct position.
**NOTES:
**
- When you remove the bucket, do not touch any parts inside of the unit. Doing so may damage the product.
- Be sure to push the bucket gently all the way into the unit. Banging the bucket against anything or failing to push it in securely may cause the unit not to operate.
- If the pump hose drops when you remove the bucket (see Fig.7),you must reinstall the pump hose properly to the unit before replace the bucket into the unit (see Fig.8).
- When you remove the bucket,if there is some water in the unit you must dry it.
- When the unit is on, if the bucket is removed, the compressor and the fan turn off, then the unit will beep 8 times and the digital display shows Eb.
- When the unit is off, if the bucket is removed, the unit will beep 8 times and the digital display shows Eb.
Continuous draining
Water can be automatically emptied into a floor drain by attaching the unit
with a water hose (Id 5/16 , not included) with a female threaded end (ID:M=1
, not included)
NOTE: On some models, the female threaded end is included
- Remove the plastic cover from the back drain outlet of the unit and set aside, then insert the drain hose through the drain outlet of the unit and lead the drain hose to the floor drain or a suitable drainage facility. (See.Fig.9and Fig.10)
- When you remove the plastic cover, if there is some water in the back drain outlet of the unit you must dry it.
- Make sure the hose is secure so there are no leaks and the end of the hose is level or down to let the water flow smoothly.
- Direct the hose toward the drain,making sure that there are no kinks that will stop the warter flowing.
- Select the desired humidity setting and fan speed on the unit for continuous draining to start.
NOTE: When the continuous draining feature is not being used,remove the drain hose from the outlet, and dry the water in the continuous drain hose outlet.
Removing the collected water
Pump draining (on some models)
Water can be automatically emptied into a floor drain or a suitable drainage
facility by attaching the pump drain out with a pump drain hose ( od=1/4 ,
supplied).
-
Remove the continuous drain hose from the unit and install the plastic cover to the continuous drain hose outlet of the unit by clockwise rotation.(See Fig.11)
-
Resert the pump drain hose into the pump drain hose outlet for depth of 15mm at least (See Fig.11), then lead the water hose to the floor drain or a suitable drainage facility.
-
Press the pump pad of the unit to activated the pump operation. When the bucket is full the pump starts to work.
NOTE: The pump may cause big noise when it starts to work for 3~5 minutes. It is a normal phenomenon. -
Make sure the hose is secure so there are no leaks.
-
Direct the hose toward the drain,making sure that there are no kinks that will stop the warter flowing.
-
Place the end of the hose into the drain and make sure the end of the hose is level or down to let the water flow smoothly.Do never let it up.
-
Select the desired humidity setting and fan speed on the unit for pump draining to start.
NOTE: The pump operation on light blinks at 1Hz when the pump is operational failure. Please turn off the unit and plug the power cord out. Check the following things: -
Cleaning the filter of the pump.
- Remove the bucket from the unit, take down the pump and clean the filter of the pump (See Fig.12).
-
Check that the pump drain hose does not link or block.
-
Empty the water of the bucket.
-
Reinstall the pump hose if it drops and reinstall the bucket properly. Turn on the unit. If the error repeats, call for service.
-
Press the pump drain hose outlet in and take the pump drain hose out from it (See Fig.13). Make sure do not let the water in the pump hose drip to the floor.
CARE AND MAINTENANCE
Care and cleaning of the dehumidifier
Turn the dehumidifier off and remove the plug from the wall outlet before
cleaning.
Clean the Grille and Case
- Use water and a mild detergent. Do not use bleach or abrasives.
- Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
- The air intake and outlet grilles get soiled easily, so use a vacuum attachment or brush to clean.
Clean the bucket
Every few weeks, clean the bucket to prevent growth of mold, mildew and
bacteria. Partially fill the bucket with clean water and add a little mild
detergent. Swish it around in the bucket, empty and rinse.
NOTE: Do not use a dishwasher to clean the bucket. After clean, the
bucket must be in place and securely seated for the dehumidifier to operate.
Clean the air filter
-
Remove the filter every two weeks based on normal operating conditions.
-
To remove the filter, pull filter outwards (See Fig.14).
-
Wash the filter with clean water then dry.
-
Re-install the filter,replace Bucket.
CAUTION:
DO NOT operate the dehumidifier without a filter because dirt and lint will
clog it and reduce performance.
When not using the unit for long time periods
- After turning off the unit, wait one day before emptying the bucket.
- Wrap the cord with the power cord buckle.
- Clean the main unit, water bucket and air filter.
- Cover the unit with a plastic bag.
- Store the unit upright in a dry, well-ventilated place.
Before calling for service, review the chart below first yourself.
Problem | What to check |
---|---|
Unit does not start | Make sure the dehumidifier s plug is pushed completely |
into the
outlet.
Check the house fuse/circuit breaker box.
Dehumidifier has reached its preset level or bucket is full.
Water bucket is not in the proper position
Dehumidifier does not
dry the air as it should| Did not allow enough time to remove the moisture.
Make sure there are no curtains, blinds or furniture blocking the
front or back of the dehumidifier.
The humidity control may not be set low enough.
Check that all doors, windows and other openings are securely
closed.
O O Room temperature is too low, below 5 C(41 F).
There is a kerosene heater or something giving off water vapor
in the room.
The unit makes a loud
noise when operating| The air filter is clogged.
The unit is tilted instead of upright as it should be.
The floor surface is not level.
Frost appears on the
coils| This is normal. The dehumidifier has Auto defrost feature.
Water on floor| Hose to connector or hose connection may be loose.
Intend to use the bucket to collect water, but the back
drain plug is removed.
ES, AS,P2,EC ,Eb and
E3 appear in the display| These are error codes and protection code. See the
CONTROL
PADS ON THE DEHUMIDIFIER section.
The pump operation
on light blinks at 1Hz| Clean the filter of the pump.
Check the pump hose does not link or block.
Empty the water of the bucket.
SOCIABLE REMARK
When using this dehumidifier in the European countries, the following information must be followed:
DISPOSAL: Do not dispose this product as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary. It is
prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic
waste can be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product
at least free of charge.
C) The manufacture will take back the old appliance for disposal at least
free of charge to the user.
D) As old products contain valuable resources, they can be sold to scrap
metal dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.