KEYSTONE KTS-MW3-12V-PKO /X Area Light Led Microwave Occupancy/Daylight Sens Instruction Manual
- June 3, 2024
- Keystone
Table of Contents
- KEYSTONE KTS-MW3-12V-PKO /X Area Light Led Microwave Occupancy/Daylight
- DESCRIPTION
- PRODUCT FEATURES
- PERFORMANCE SPECIFICATIONS
- PHYSICAL SPECIFICATIONS
- LUX ON/OFF SETTING
- INSTALLATION
- ACCESSORY (SOLD SEPARATELY)
- ORDERING INFORMATION
- CATALOG NUMBER BREAKDOWN
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KEYSTONE KTS-MW3-12V-PKO /X Area Light Led Microwave Occupancy/Daylight
Sens
DESCRIPTION
LED Microwave Occupancy/Daylight Sensor | Pre-wired for Quick Installation | Performance Parameters Set by Remote Control (sold separately)
INPUT VOLTAGE: 12Vdc ± 2Vdc
MICROWAVE FREQUENCY: 5.8 GHz ± 75MHz
OUTPUT VOLTAGE: 0–10Vdc
TRANSMIT POWER: 1mW max.
PRODUCT FEATURES
- Partial discharge (PD) dual-technology differentiates artificial light brightness from natural light and automatically turns off light when ambient brightness exceeds preset lux level
- Microwave sensing technology detects motion in the coverage area and automatically turns off light when motion is no longer detected
- Pre-wired for quick installation
- Powered by Keystone 0–10V dimming LED driver
- Adjustable performance parameters set by Keystone remote control (sold separately)
- Ambient operating temperature: −25ºC/−13ºF to 60ºC/140ºF
PERFORMANCE SPECIFICATIONS
Adjustable Settings | |
---|---|
Microwave Frequency | Input Voltage |
Output Voltage | Transmit Power |
Max Mounting Height | Detection Angle |
Range | **** |
Brightness
| ****
Sensitivity
| Hold Time| Daylight Threshold| Stand-By Time| Stand-By Dimming Level
5.8GHz
| ****
12Vdc
| ****
30mA
| ****
0–10V
| ****
1mW
| ****
<0.5W
| ****
33 ft (ceiling mount)
| ****
30º–150º
| Ceiling mount: ø 33 ft max
Wall mount: 35 ft max
| 70%
80%
90%
100%
| 20%
50%
75%
100%
| 10 sec
1 min
10 min
30 min
| 10 Lux
30 Lux
50 Lux
100 Lux Disable
| 1 min
30 min 60∞min
| 10%
20%
30%
50%
FACTORY PRESETS
Catalog Number| Stand-By Dim Level| Hold Time|
Daylight Threshold| Stand-By Time
---|---|---|---|---
KTS-MW3-12V-PKO| 50%| 10 min| Disabled| ∞
KTS-MW3-12V-PKO /A| 30%| 1 min| Disabled| 3 min
KTS-MW3-12V-PKO /B| 10%| 5 min| Disabled| 10 min
PHYSICAL SPECIFICATIONS
LUX ON/OFF SETTING
FUNCTION
Partial discharge (PD) dual-technology differentiates artificial light
brightness from natural light and automatically turns off light when ambient
brightness exceeds preset lux level.
Lux-Off function preconditions:
- Stand-by period setting: ∞ • Stand-by dimming level setting: 10%, 20%, 30%, or 50%
- Daylight threshold setting: 10 Lux, 30 Lux, 50 Lux, or 100 Lux
APPLICATION
- When ambient light is lower than preset lux level, lighting will turn on and remain at preset stand-by dimming level.
- With insufficient ambient light, when motion is detected, lighting will turn on and remain at preset brightness level until motion is no longer detected for duration of preset hold time.
- If no further motion is detected after duration of hold time, lighting will dim and remain at preset brightness level for duration of standby time or until ambient light level exceeds preset lux level.
- When ambient light reaches preset lux level, lighting will turn of and remain off until ambient light level falls below preset lux level.
INSTALLATION
- Ensure power is off to the fixture.
- Remove 1/2″ knock-out (KO) plug next to the Keystone emblem on the driver access door.
- Screw in sensor head.
- Re-connect power when ready. (see illustrations below)
- Program desired settings as needed with Keystone Remote Control.
ACCESSORY (SOLD SEPARATELY)
REMOTE CONTROL|
---|---
Catalog Number| Description| UPC| Easy Code
KTS-MW3-REMOTECONTROL| Remote Control for KTS-MW3-12V-XX Sensors, Sets/adjusts
all sensor performance parameters| 843654132020| XSR-61
ORDERING INFORMATION
ORDER CODE | PACK QTY. | UPC | Easy Code |
---|---|---|---|
KTS-MW3-12V-PKO | 1 | 843654135212 | TRM-32 |
KTS-MW3-12V-PKO /A | 1 | 843654133317 | XYR-25 |
KTS-MW3-12V-PKO /B | 1 | 843654133324 | SPF-37 |
CATALOG NUMBER BREAKDOWN
- Keystone Technologies Sensor
- Microwave Sensor Form Factor
- Input Voltage—12V
- Pin Connection
- Knock Out
- Preset Configuration Style
Preset Configuration Style
Blank | Standard Factory Preset |
---|---|
/A | Factory Preset A |
/B | Factory Preset B |
Keystone Technologies
- Philadelphia, PA
- Phone 800-464-2680
- www.keystonetech.com