VOID Air 8 Sleek Contours Streamlined Precision User Guide

June 4, 2024
VOID

VOID Air 8 Sleek Contours Streamlined Precision

1 Safety and Regulations

Important safety instructions

The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous  voltage” within the product’s enclosure that mabe of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

Safety instructions – read this first
  1. Read these instructions.

  2. Keep these instructions.

  3. Heed all warnings.

  4. Follow all instructions.

  5. Do not use this apparatus near water.

  6. Clean only with a dry cloth.

  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

  8. Do not install near any heat source such as radiators, heat registers, stoves, or other such apparatus that produce heat.

  9. Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong.
    The third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

  10. Protect power cords from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit the apparatus.

  11. Only use attachments and accessories specified by Void Acoustics.

  12. Only use with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

  13. Unplug the apparatus during lightning storms or when unused for long periods of time.

  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

  15. Since the mains power supply cord attachment plug is used to disconnect the device, the plug should always be easily accessible.

  16. Void loudspeakers can produce sound levels capable of causing permanent hearing damage from prolonged exposure.
    The higher the sound level, the less exposure needed to cause such damage. Avoid prolonged exposure to the high sound levels from the loudspeaker

Limitations

This guide is provided to help familiarise the user with the loudspeaker system and its accessories. It is not intended to provide comprehensive electrical, fire, mechanical and noise training and is not a substitute for industry-approved training. Nor does this guide absolve the user of their obligation to comply with all relevant safety legislation and codes of practice. While every care has been taken in creating this guide, safety is userdependent and Void Acoustics Research Ltd cannot guarantee complete safety whenever the system is rigged and operated.

EC declaration of conformity

For EC Declaration of Conformity please go to: www.voidacoustics.com/eu- declaration-loudspeakers

UKCA marking

For details of the UKCA marking go to: www.voidacoustics.com/uk-declaration- loudspeakers

Warranty statement

For warranty statement go to: https://voidacoustics.com/terms-conditions/

WEEE directive

If the time arises to throw away your product, please recycle all the components possible.

This symbol indicates that when the end-user wishes to discard this product, it must be sent to separate collection facilities for recovery and recycling. By separating this product from other household-type waste, the volume of waste sent to incinerators or land-fills will be reduced and natural resources will thus be conserved.

The Waste Electrical and Electronic Equipment Directive (WEEE  Directive) aims to minimise the impact of electrical and electronic goods on the environment. Void Acoustics Research Ltd complies with the Directive 2002/96/EC and 2003/108/EC of the European Parliament on waste electrical finance the cost of treatment and recovery of electronic equipment (WEEE) in order to reduce the amount of WEEE that is being disposed of in land-fill sites. All of our products are marked with the WEEE symbol; this indicates that this product must NOT be disposed of with other waste. Instead it is the user’s responsibility to dispose of their waste electrical and electronic equipment by handing it over to an approved reprocessor, or by returning it to Void Acoustics Research Ltd for reprocessing. For more information about where you can send your waste equipment for recycling, please contact Void Acoustics Research Ltd or one of your local distributors.

Unpacking and Checking

All Void Acoustics products are carefully manufactured and thoroughly tested before being despatched. Your dealer will ensure that your Void products are in pristine condition before being forwarded to you but mistakes and accidents can happen.

Before signing for your delivery:

  • Inspect your shipment for any signs of contamination, abuse or transit damage as soon as you receive it
  • Check your Void Acoustics delivery fully against your order
  • If your shipment is incomplete or any of its contents are found to be damaged; inform the shipping company and inform your dealer.

When you are removing your Air 8 loudspeaker from its original packaging:

  • Air 8 loudspeakers come double boxed and are stapled shut; take care when unboxing and removing the staples to avoid injury or damage to the loudspeaker
  • If you need to place the Air 8 loudspeaker on a flat surface ensure you use a lint free product to protect the finish
  • When you have removed the Air 8 loudspeaker from the packaging inspect it to ensure there is no damage and keep all original packaging in case it needs to be returned for any reason.

See section 1.5 for warranty conditions and see section 6 if your product needs servicing.

About

Welcome

Many thanks for purchasing this Void Acoustics Air 8. We truly appreciate your support. At Void, we design, manufacture and distribute advanced professional audio systems for the installed and live sound market sectors. Like all Void products, our highly skilled and experienced engineers have successfully combined pioneering technologies with groundbreaking design aesthetics, to bring you superior sound quality and visual innovation. In buying this product, you are now part of the Void family and we hope using it brings you years of satisfaction. This guide will help you both use this product safely and ensure it performs to its full capability

Air 8 overview

The Air 8 is an interior designer’s dream come true and a sound purist’s heaven. Highly refined in-house designed components, combined in a modern work of art. This installation-friendly package provides impressive efficiency for its compact, stylish form.

Key features
  • Passive 8” two-way surface mount loudspeaker
  • Linear frequency and phase characteristics
  • High-power internal crossover for ease of setup
  • Low resonance fibreglass composite construction
  • Supplied T51 wall bracket
  • Optimised dispersion provides greater direct to reflected sound
  • Phoenix Connector with Link Out
Air 8 specifications
Configuration 1 x 8” : 1 x 1” Coax
Frequency response 70 Hz – 20 kHz ±3 dB
Maximum output1 119 dB cont, 125 dB peak
Sensitivity2 95 dB 1W/1m
Impedance 8 Ù
Power handling3 300 W AES
Dispersion 90°H x 90°V
Connectors Phoenix
Construction Fibreglass
Mounting T51 wall bracket (supplied)
Height 419 mm (16.5”)
Width 300 mm (11.8”)
Depth 172 mm (6.7”)
Weight 6.2 kg (13.7 lbs)
Colour Custom colours available upon request

1 Calculated 2 Measured in half space 3 AES2 – 1984 compliant

Air 8 dimensions

Cable and Wiring

Electrical safety

To avoid electrical hazards please note the following:

  • Do not access the inside of any electrical equipment. Refer servicing to Void-approved service agents.
Cable considerations for fixed installations

We recommend specifying installation-grade Low Smoke Zero Halogen (LSZH) cables for permanent installations. The cables should use Oxygen Free Copper (OFC) of grade C11000 or above. Cables for permanent installations should be compliant with the following standards:

  • IEC 60332.1 Fire retardancy of a single cable
  • IEC 60332.3C Fire retardancy of bunched cables
  • IEC 60754.1 Amount of Halogen Gas Emissions
  • IEC 60754.2 Degree of acidity of released gases
  • IEC 61034.2 Measurement of smoke density

We suggest using the following maximum copper cable lengths to keep level losses below 0.6 dB.

Metric mm2 Imperial AWG 8 load 4 load 2 Ù load
2.50 mm2 13 AWG 36 m 18 m 9 m
4.00 mm2 11 AWG 60 m 30 m 15 m
Air 8 wiring diagram

| Phoenix pins 1+/1-| Phoenix pins 2+/2-
---|---|---
In| 8” LF + 1” HF| Link/out

Bias D1/Q1/Q2 Phoenix wiring

Bias D1/Q1/Q2 Out 1
Output LF (8”) and HF (1”)
Max parallel units 4 (2 Ù load to amplifier)
Bias Q5 speakONTM wiring
Bias Q5 Out 1
Output LF (8”) and HF (1”)
Max quantity per channel 4 (2 Ù load to amplifier)

Mounting

Installation safety

To avoid mechanical hazards, please note the following:

  • Safety regulations vary in different regions. Full compliance with those regulations must be your priority

  • Rigging must only be undertaken by fully-qualified and experienced
    riggers who understand local regulations

  • This may include consulting a structural engineer before installation of wall brackets

  • Remember that all personnel have a duty of care to themselves, to their assistants, to the venue staff and to the public

  • Before lifting any part of the system above head height, check the whole rig for loose tools or other items that may fall and cause injury

  • Do not use a telephone (even if hands-free) while mounting. Always concentrate fully on the installation

  • Do not mount equipment that is worn, damaged, corroded, mishandled or overstressed in any way

  • Use only Void-approved mounting equipment and accessories

  • Secondary safeties should be provided in all instances where cabinets are flying or fixed overhead and should conform to local regulations

 Wall Mounting

5.2 Wall Mounting

4 mm Allen key

T51 – Wall Bracket White – IT2992 (supplied)

Black – IT3031 (supplied)

Step 1:
Remove all four M6 bolts from the rear of the loudspeaker.

Step 2:
Remove the mounting plate from the wall bracket by removing the M6 countersink as shown.

Step 4:
Fit the mounting plate to the rear of the Air 8 with the bolts provided.

Step 5:
Fix the bracket to the wall in compliance with local regulations. Once it is secure lift the Air 8 with the mounting plate fixed to it into position and fix it to the bracket using the M6 countersink bolt that was removed in step

Step 6a:
When adjusting the Air 8 into position if the intention is to have as close to the wall as possible then adjust the bracket to the configuration shown in figure 5.6a.
Max horizontal rotation: 42°
Max vertical rotation: 25°

Step 6b:
When adjusting the Air 8 into position if the intention is to have maximum horizontal rotation then use adjust the bracket to the configuration shown in figure 5.6b.
Max horizontal rotation: 57°
Max vertical rotation: 50°

Ceiling Mounting

Part required:

T51 – Ceiling Bracket White – IT3802

Black – IT3354

4 mm Allen key
19 mm spanner

Step 1:
Remove the mounting plate from the bracket by removing the M12 bolt as shown

Step 2:
Remove all four M6 bolts from the rear of the loudspeaker.

Step 3:
Attach the mounting bracket to the rear of the loudspeaker using all four M6 bolts

Step 4:
Fix the bracket to the ceiling using all eight bolts. Once it is secure lift the Air 8 with the mounting plate fixed to it into position and fix it to the bracket using the M12 nut that was removed in step 1.
Max horizontal rotation: 360°
Max vertical rotation: 13°

Stud Mount

Part required:
4 mm Allen key

T51 – Stud Bracket Black – IT3438

White – IT3439

Step 1:
Remove all four M6 bolts from the rear of the loudspeaker.

Step 2:
Attach the stud bracket using all four M6 bolts.
The product can now be mounted to third party hardware using the M12 mounting position.

Pole Mount

Part required:
4 mm Allen key

T51 – Pole Bracket Black – IT3727

White – IT3728

Step 1:
Remove all four M6 bolts from the rear of the loudspeaker.

Step 2:
Attach the pole bracket kit using all four M6 bolts.
Max horizontal rotation: 360°
Max vertical rotation: 12°

Service

Void Air 8 loudspeakers should only be serviced by a fully-trained technician.

No user serviceable parts inside. Refer servicing to your dealer.

Return authorisation

Before returning your faulty product for repair, please remember to get an R.A.N. (Return Authorisation Number) from the Void dealer who supplied the system to you. Your dealer will handle the necessary paperwork and repair. Failure to go through this return authorisation procedure could delay the repair of your product.

Note that your dealer will need to see a copy of your sales receipt as proof of purchase so please have this to hand when applying for return authorisation.

Shipping and packing considerations
  • When sending a Void Air 8 loudspeaker to an authorised service centre, please write a detailed description of the fault and list any other equipment used in conjunction with the faulty product.
  • Accessories will not be required. Do not send the instruction manual, cables or any other hardware unless your dealer asks you to.
  • Pack your unit in the original factory packaging if possible. Include a note of the fault description with the product. Do not send it separately.
  • Ensure safe transportation of your unit to the authorised service centre.

Appendix

Architectural specifications

The loudspeaker shall be a passive two-way system consisting of one high power 8” (203.2 mm) direct radiating reflex loaded low frequency (LF) transducer and a 1” (25 mm) diameter co-axially-mounted neodymium high frequency (HF) compression transducer mounted in a fibreglass, smooth cellulose enclosure.

The low frequency transducer shall be constructed on a cast aluminium frame, with a treated paper cone, 50.8 mm (2”) voice coil, wound with copper wires on a high quality voice coil former, for high power handling and long-term reliability. The high frequency  transducer shall be bolted through the rear of the magnet structure belonging to the LF transducer to form a co-axial drive unit. The sound will project through a machined waveguide that exits in the centre of the low frequency transducer to use the 203.2 mm (8”) baffle diameter to achieve pattern control and low distortion.

Performance specifications for typical production unit shall be as follows: the usable onaxis bandwidth shall be 70 Hz to 20 kHz (±3 dB) and shall average 90° directivity pattern for both horizontal and vertical axis (-6 dB down from on-axis level) from 1 kHz to 10 kHz; maximum SPL of 119 dB continuous, 125 dB peak measured at 1 m using IEC268-5 pink noise. Power handling shall be 300 W AES at a rated impedance of 8 Ω; crossover point at 2 kHz using a 4th order filter (24 dB per octave).

The wiring connection shall be via a single, removable, lockable wiring connector with four screw-down terminals (one pair for input and one pair for loop-out to another loudspeaker) to provide secure wiring and to allow for pre-wiring of the connector before the installation.
This connector should then screw lock to the enclosure to ensure secure attachment.

The enclosure shall be of a moulded fibreglass reinforced plastic construction with a smooth cellulose finish and shall include integral threaded inserts for the fitment of wall and ceiling mounting hardware of any RAL colour with external dimensions of (H) 419 mm x (W) 300 mm x (D) 172 mm (16.5” x 11.8” x 6.7”). Weight shall be 6.2 kg (13.7 lbs).

The loudspeaker shall be the Void Acoustics Air 8.

NORTH AMERICA
Void Acoustics North America
Call: +1 503 854 7134
Email: [email protected]

HEAD OFFICE
Void Acoustics Research Ltd,
Unit 15, Dawkins Road Industrial Estate,
Poole, Dorset,
BH15 4JY
United Kingdom
Call: +44(0) 1202 666006
Email: [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VOID User Manuals