Acekool CW2 Window Air Conditioner User Manual

October 30, 2023
ACEKOOL

Acekool CW2 Window Air Conditioner

Acekool-CW2-Window-Air-Conditioner-PRODUCT

Product Information

The Acekool Window Air Conditioner CW2 is a cooling appliance designed to regulate the temperature and humidity in your home. It has an auto-speed feature that automatically adjusts the fan speed to maintain the desired temperature. The appliance also has an auto mode that automatically selects the appropriate temperature and fan speed based on the room’s ambient conditions. The air conditioner uses Refrigerant R32, which provides efficient cooling while being environmentally friendly.

Product Usage Instructions

  1. Before operating the air conditioner, read the user manual carefully and store it in a safe place for future reference.

  2. Ensure that the electrical requirements of the air conditioner are met. Plug the appliance into a grounded 3-prong outlet and do not use an adapter or extension cord.

  3. The air conditioner must be installed and assembled according
    to the instructions provided in the manual. Use two or more people to move and install the appliance.

  4. After installation, turn on the air conditioner and select the desired temperature and fan speed using the control panel.

  5. The auto-speed feature will adjust the fan speed automatically to maintain the desired temperature. To use the auto mode, select it using the control panel, and the air conditioner will select the appropriate temperature and fan speed based on the room’s ambient conditions.

  6. Regularly clean and maintain the air conditioner as per the instructions provided in the manual.

  7. If you experience any issues with the air conditioner, refer to the troubleshooting section of the manual.

Remember, to reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow all safety precautions outlined in the user manual.

Important Safety Instructions

Before installing and using your air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this user manual.

Warning
To reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow the basic precautions below:

  • Plug into a grounded 3-prong outlet.
  • Do not remove the ground prong.
  • Do not use a plug adapter.
  • Do not use an extension cord.
  • Unplug the air conditioner before servicing.
  • Use two or more people to move and install the air conditioner.

This is a safety alert symbol. This symbol alerts you to potential hazards that can harm you or others or even cause death. All safety messages will directly follow the safety alert symbol and/or the words “DANGER” or “WARNING”.

Danger: Failure to immediately follow these instructions may cause serious injury or even death.
Warning: All Safety messages alert you of potential hazards, how to reduce the chance of injury, and what can happen if instructions are not followed correctly.

Introduction to Refrigerants R32

The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of errant is combustible and odorless. Moreover, it can burn and explode under certain conditions. However, there will be no risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an appropriate area and use it correctly. Compared with ordinary refrigerants, Refrigerant R32 is environmentally friendly and does not destroy the ozone sphere and its value of greenhouse effect is also very low.

Room area requests for air conditioner with Refrigerant R32

Refrigerant Capacity(Btu) Room Area


R32

| ≤9K| Above 4m²
≤12K| Above 4m²
≤18K| Above 15m²
≤24K| Above 25m²

Warning

  • Please read the manual before installation, use, and maintenance.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • Do not pierce or burn the appliance.
  • The appliance shall be stored in a room without continuously operating sources (for example open flames, an operating ignition gas appliance o r an operating electric heater.)
  • Please contact the nearest after-sale service center when maintenance is necessary.
  • At the time of maintenance, the maintenance personnel must strictly comply with
  • the Operation Manual provided by the corresponding manufacturer, and any nonprofessional is prohibited to maintain the air conditioner.
  • The handling, installation, storage, servicing, and disposal must comply with the
  • provisions of gas-related national laws and regulations, and also national wiring regulations.
  • It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner. Be aware that refrigerants may not contain an odour.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Unit operation limits Outdoor side 61~110, 80%RH, indoor side 61~90, 80%RH.

Electrical Requirements

Warning

Electrical Shock

  • Hazard Plug into a grounded 3-prong outlet.
  • Do not remove the ground prong.
  • Do not use an adapter.
  • Do not use an extension cord.
  • Failure to follow these instructions can result in death, fire, or electrical shock.

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front). Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord .Acekool-CW2-Window-Air-Conditioner-fig-1

Recommended Ground Method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

  • To contact a qualified electrician.
  • To assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition, and all local codes and ordinances.

LCDI Power Cord and Plug

  • This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is requiredby UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit.
  • The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly.

To test the plug:

  • Plug power cord into a grounded 3 prong outlet
  • Press RESET (on some units a green light will turn on).
  • Press the TEST Button, the circuit should trip and cut all power to the air conditioner (on some units a green light may turn off).
  • Press the RESET button for use. You will hear a click and the A/C is not ready for use.

NOTES:

  • The RESET button must be engaged for proper use.
  • The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to rese.
  • Do not use the power supply cord as an ON/OFF switch. The power supply cord is designed as a protection device.
  • A damaged power supply cord must be replaced with a new power supply cord.
  • The power supply cord contains new user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.

NOTES: Your units power cord and plug may differ from the one shown.

Packing List

Acekool-CW2-Window-Air-Conditioner-fig-3

Installation & Assembly Instructions

Some assembly is required for your new air conditioner. Please read and follow these instructions carefully.

  • This air conditioner is designed to be installed in a standard double-hung window with a window width between 23″ and 36″ (584mm-914 mm).
  • The air conditioner can be installed without the accordion panels to fit in a narrow window opening. See the window dimensions.
  • The Lower Sash (the lower part of the window that moves up and down) must allow for 14.5″ of vertical clearance when open. (See Fig.1).
  • All supporting parts must be secured to firm wood, masonry, or metal.
  • The electrical outlet must be within reach of the power cord.
  • The air conditioner should be tilted about 3° for better drainage of condensate and rainwater.Acekool-CW2-Window-Air-Conditioner-fig-4

NOTE:

  • Save the product packaging and installation instructions for future reference.
  • Store the air conditioner in the product box when not in use for an extended period of time.

Top Rail Assembly
Attaching the Top Rail to the Air Conditioner The top rail must be assembled prior to installing the air conditioner in the window. Tools Needed: Phillips Head Screw Driver 3/8″Screws *4
NOTE: For safety reasons, all 4 screws must be used to attach the top rail. Remove the air conditioner from the box and place on a hard and flat surface. Remove top rail from the top of the packaging material as shown in Fig.A. Align the hole in the top rail with those in the top of the unit as shown in Fig.B. Secure the top rail to the unit with the 3/8″ screws as shown in Fig.C.
Caution: When handling the unit, be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils.Acekool-CW2
-Window-Air-Conditioner-fig-5

How to Install

NOTE: Top Rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16″). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels forany reason, this pitch to the rear must be maintained!

  1. Place unit on floor, a bench or a table. There is a Left and Right Window Filler Panelbe sure to use the proper panel for each side. When installed the flange for securing the panel in place to the window sill will be facing into the room.
    • Hold the Accordion Panel in one hand and gently pull back the center to free the open end. See Fig.2.
    • Slide the free end of the panel into the cabinet as shown in Fi.3. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.Acekool-CW2-Window-Air-Conditioner-fig-6
    • Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making
    • slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. See Fig.4. Slide the panel all the way in and repeat on the other side.
  2. Keep a firm grip on the air conditioner, carefully place the uni t into the window opening so the bottom of the air conditioner frame is against the window sill (Fig.5). Carefully close the window behindthe top rail of the unit. (Suggest to keep a downward oblique, to let accumulated rain water to drain out, from back side of the unit bottom.)
  3. Extend the side panels out against the window frame (Fig.6).Acekool-CW2-Window-Air-Conditioner-fig-8
  4. Place the frame lock between the frame extensions and the window sill as shown (Fig.7). Drive 3/4″ (19 mm) locking screws through the frame lock and into the sill (Fig.8).
    • NOTE: To prevent window sill from splitting, drill 1/8″ (3 mm) pilot holes before driving screws.Acekool-CW2-Window-Air-Conditioner-fig-9
  5. Drive 1/2″ (12.7mm) locking screws throughframe holes into window sash (Fig.9 Fig10).Acekool-CW2-Window-Air-Conditioner-fig-10
  6. To secure lower sash in place, attach right angle sash lock with 3/4″ (19 mm) screw as shown (Fig.11).
  7. Cut foam seal and insert in the space between the upper and lower sashes (Fig.12).Acekool-CW2-Window-Air-Conditioner-fig-11

If AC is Blocked by Storm Window

Add wood as shown in Fig.13, or remove the storm window before the air conditioner is installed.Acekool-CW2-Window-Air-Conditioner-
fig-12 If Storm Window Frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out.

Removing AC From Window

  • Turn AC off, and disconnect power cord.
  • Remove sash seal from between windows, and unscrew safety lock.
  • Remove screws installed through frame and frame lock.
  • Close (slide) side panels into frame.
  • Keeping a firm grip on air conditioner, raise sash and carefully “rock” air conditioner
  • backward to drain any condensate water in base of unit. Be careful not to spill any
  • remaining water while lifting unit from window.
  • Store parts with air conditioner.

Air Conditioner Use

Operating your air conditioner properly helps you to obtain the best possible results. This section explains proper air conditioner operation.

IMPORTANT:

  • If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This prevents the air conditioner from blowing a fuse or tripping a circuit breaker.
  • Do not try to operate your air conditioner in the cooling mode when outside temperature is below 65°F (18°C). The inside evaporator coil will freeze up, and the air conditioner will not operate properly.

NOTE: In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored.

Introduction to Refrigerants R32

  • Before installing the appliance, you must read the manual carefully to get the safety information and notes.
  • When filling the combustible refrigerant, any of your rude operations may cause serious injury or injuries to human body or bodies and object or objects.
  • A leak test must be done after the installation is completed.
  • It is a must to do the safety inspection before maintaining or repairing an air conditioner using combustible refrigerant in order to ensure that the fire risk is reduced to minimum.
  • It is necessary to operate the machine under a controlled procedure in order to ensure that any risk arising from the combustible gas or vapor during the operation is reduced to minimum.
  • Requirements for the total weight of filled refrigerant and the area of a room to be equipped with an air conditioner.

Site Safety

Acekool-CW2-Window-Air-Conditioner-fig-13

Operation SafetyAcekool-CW2-Window-Air-Conditioner-
fig-14

Installation Safety

  1. Refrigerant Leak Detector
  2. Appropriate Installation Location
  3. The left picture is the schematic diagram of arefrigerant leak detector

Please note that:

  • The installation site should be in a well-ventilated condition.
  • The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven or any o ther heat source higher than 548°C which easily produces open fire.
  • When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static clothing and/or gloves.
  • It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and/or explosive environment.
  • If the indoor unit suffers refrigerant leak during the installat ion, all the personnel should go out till the refrigerant leaks completely for 15 minutes. If the product isdamaged, it is a must to carry such damaged product back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user’s site.
  • It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
  • It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit, and also prevent mechanical damage from occurring.

Using Your Air Conditioner

Normal Operating Sounds

  • You may hear a pinging noise caused by water hitting the condenser, on rainy days, or
  • when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and off.
  • Water will collect in the base pan during rain or days of high humidity. The water may overflow and drip from the outside part of the unit.
  • The fan may run even when the compressor is not on.

Electronic Control Panel

NOTE: This display always shows the room temperature in Fan Mode except when setting the Set temperature or the Timer. Acekool-CW2-Window-Air-
Conditioner-fig-16

  1. Digital Display:
    Without timer setting, the operation mode is Cooling, Dry, Fan, and Auto, and the set temperature will be displayed. Time will be displayed under the timer setting.

  2. and Button:
    Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61°F~88°F or 16°C~31°C.

  3. 3. Power Button:
    Turn the air conditioner on and off.

  4. Mode Button:
    Press the mode button to cycle through the various modes: Cool, Dry, Fan and Auto.

    • Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces humidity. Press the MODE button to activate the cooling function. To optimize this function adjust the temperature by pressing the up and down arrows and the speed by pressing the Fan Speed button.
    • Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press the MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated.
    • Fan Mode: This function only works when the air conditioner is vented. Press the MODE button to set the FAN mode. With pressing the FAN SPEED button, the speed changes in the following sequence: HIGH, MED, LOW in FAN mode. The remote control also stories the speed that was set in the previous mode of operation. Auto Mode: In AUTO mode the unit automatically chooses the mode of operation (COOL, DRY, or FAN). In this mode the temperature is set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit).
  5. 5. Timer Button:
    Use these buttons on the control panel and remote to set the Timer.

    • Timer Off: The timed stop is programmed by pressing the TIMER button. Set the rest time by pressing the button or until the rest time displayed is to your demand then press TIMER button again.

    • Timer On: When the unit is off, press the TIMER button for the first time, and set the temperature by pressing the button or. Press the TIMER button at the second time, set the rest time by pressing the button or . Press TIMER button at the second time, set the
      rest time with pressing the button or Press the TIMER button the third time, confirm the setting, then the rest time to the next automatical switching-on could be read on the display of the machine.

    • Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increments below 10 hours and 1-hour increments for 10 hours or above. The SET light will turn on while setting. To cancel the setted function, press the TIMER button again.

  6. Eco Button:
    When the unit is in ECO mode, thelight will turn on. In ECO mod e, the unit will turn off once the room is cooled to the user-set temperature. The unit will turn back on when the room temperature rises above the user-set temperature. Before the compressor starts, the fan motor will run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy.

  7. Sleep Button:
    Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes, and at most change six times until the set temperature is 81°F or 82°F.

  8. Fan Speed Button:
    Press the FAN SPEED button to choose the fan speed options. You can choose HIGH, MED, LOW or auto speed in COOL mode and choose HIGH, MED, LOW in FAN mode.

  9. Filter Button:
    When the Filter Check light is off, it is not necessary to press the Filter Check button. When the Filter Check light is on, you can turn off the light by pressing the Filter Checkbutton. After the fan motor works for 500 total hours, the Filter Check light will turn on to remind the user to clean the filter.

  10. Directional Louvers:
    To direct the airflow, use the horizontal wheel to control the horizontal direction, control the vertical direction.Acekool-CW2-Window-Air-
Conditioner-fig-19

REMOTE CONTROL

  1. POWER
    Turn the air conditioner on and off.

  2. Cool
    Press the COOL button to COOL mode.

  3. Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer.
    Temperature range : 61°F ~88°F or 16°C ~31°C .

  4. Sleep
    Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes and at most change six times until the set temperature is 81°F or 82°F.

  5. Timer
    Use these buttons on the control panel and remote to set the Timer.

  6. Timer Off:
    The timed stop is programmed by pressing the TIMER button. Set the rest time by pressing the button or until the rest time displayed is to your demand then press the TIMER button again.

  7. Timer On: When the unit is off, press the TIMER button for the first time, and set the temperature by pressing the button or . Press the TIMER button at the second time, and set the rest time with pressing the button or . Press TIMER button at the third time, confirm the setting, then it will show on the display.

  8. Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increments below 10 hours and 1-hour increments for 10 hours or above. The SET light will turn on while setting. To cancel the set function, press the TIMER button again.

  9. Auto Mode
    In AUTO mode the unit automatically chooses the mode of operation (COOL, DRY or FAN). In this mode, the temperature will be set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.).

  10. Fan Speed
    Press the FAN SPEED button to choose the fan speed options. You can choose HIGH, MED, LOW or auto speed in COOL mode and choose HIGH, MED, or LOW in FAN mode.

  11. Display
    To press the DISPLAY button, it can switch off/on all lights or LED displays.

  12. ECO
    When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off
    once the room is cooled to the user-set temperature. The unit will turn back on when the
    room temperature rises above the user-set temperature. Before the compressor starts,
    the fan motor will run for a while, then it will stop for a while, and will repeat to provide
    a much more comfortable feeling and save energy.

  13. Fan Only
    Press the Fan Only button to FAN ONLY mode.

    • Battery Size:
      AAA-NOTE: Do not mix old and new batteries or different types of AAA batteries.

Care and Cleaning

Clean your air conditioner to keep it looking new and to minimize dust build- up.

Air Filter Cleaning

The air filter should be checked at least once every month to see if it needs cleaning. Trapped particles and dust can build up in the filter and may decrease airflow as well as cause the cooling coils to accumulate frost.

To clean the air filter:

  • Remove the filter by sliding it out from the front right side of the air conditioner. (See Fig.14)
  • Wash the filter using liquid dish soap and warm water. Rinse the filter thoroughly. Gently shake the filter to remove excess water.
  • Let the filter dry completely before placing it into the air conditioner.
  • If you do not wish to wash the filter, you may vacuum the filter to remove the dust and other particles.Acekool-CW2-Window-Air-Conditioner-fig-22

Wear and Tear

To minimize wear and tear on the air conditioner, always wait at least 3 minutes before changing modes. This will help prevent the compressor from overheating and the circuit breaker from tripping.
Cabinet Cleaning
To clean the air conditioner cabinet:

  • Unplug the air conditioner to prevent shock or a fire hazard. Th e cabinet and front panel of the air conditioner may be dusted with an oilfree cloth or washed with a cloth
  • dampened in a solution of warm water and mild liquid soap. Rinse thoroughly with a damp cloth and wipe dry.
  • Never use harsh cleaners, wax or polish on the cabinet front.
  • Be sure to wring excess water from the cloth before wiping around the controls.
  • Excess water in or around the controls may cause damage to the air conditioner.

Winter Storage: To store the air conditioner when it is not in use for an extended period of time, remove it carefully from the window according to the installation instructions and cover it with plastic or place it in the original box.

Troubleshooting

Problem Possible Causes Solutions










The Air Conditioner will not start

| ****

The air conditioner is unplugged

| Make sure the air condition- er plug is pushed completely into the outlet.


The fuse is blown/circuit breaker is tripped

| Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.





Power failure

| The unit will automatically re-start when power is restored.

There is a protective time delay (approx.3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.




The current interrupter device is tripped

| Press the RESET button located on the power cord plug.

If the RESET button will not stay engaged,discontinue use of the air conditioner and contact a qualified service technician.





The Air Conditioner does not cool as it should

| ****

Airflow is restricted

| Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
The temperature control may not be set correctly| Lower the set thermostat temperature.


The air filter is dirty

| Clean the filter. See the Cleaning and Care Section of the manual.
Problem| Possible Causes| Solutions
---|---|---



The Air Conditioner does not cool as it should

| ****

The room may be too warm

| Please allow time for the room to cool down after turning on the air conditioner.
Cold air is escaping| Check for open furnace registers and cold air returns.


The cooling coils are frozen

| See “Air Conditioner Freezing Up” below.


The Air Conditioner is freezing up

| Ice blocks the air flow and stops the air conditioner from cooling the room| Set the MODE dial to HIGH FAN or HIGH COOL and set the thermostat to a higher temperature.
The Remote Control is not working| The batteries are inserted incorrectly

The batteries may be dead

| Check the position of the batteries.

Replace the batteries.

Water is dripping outside| Hot and humid weather| This is normal.


Water is dripping inside the room

| ****

The air conditioner is not correctly tilted outside

| For proper water drainage, make sure the air conditioner is slightly tilted downward from the front of the unit to the rear.


Water collects in the base pan

| ****

Moisture removed from the air is draining into the base pan

| This is normal for a short period inareas with low humidity and normal for a longer period in areas with high humidity.

Thank you for purchasing Acekool Window Air Conditioner. Before operating this unit, please read these instructions completely and keep the manual ready for further reference.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals