OZOTECH AIM PCS 200 Ozone Generator User Manual
- October 30, 2023
- OZOTECH
Table of Contents
OZOTECH AIM PCS 200 Ozone Generator User Manual
Dear Valued Customer:
Congratulations on your purchase of the AIM Series ozone generator! This user
manual was created to help you get the most out of your new device and to
assist you with the initial set up. Please visit
www.ozotech.com to learn more about this and other
products.
Thank you for choosing Ozotech products!
SAFETY FIRST
Read the following safety guidelines thoroughly before attempting to install or operate your equipment:
As with all electrical devices, this equipment should never be allowed to come in contact with water.
Only qualified personnel should be allowed to set up, operate and maintain this equipment.
Do not use an extension cord to supply power to this equipment.
Use a power conditioner if line voltage fluctuates outside of specified range.
Unit must be disconnected from power prior to performing service or repair.
Ozotech, Inc., assumes no liability for damages or injuries incurred by misuse of this product.
Installation and Operation
Your ozone generator requires special operating conditions in order to maintain performance and reliability. Your ozone generator is designed to be operated under a negative or positive pressure situation. Your ozone generator has been factory tested to operate at a maximum positive pressure of 5 psi.
The use of an air preparation device is essential to increase your ozone generator performance and service life. Ozotech Inc. provides several air preparation options, based on application. Contact your distributor, an Ozotech, Inc. sales representative, or visit www.ozotech.com for more information
Warranty coverage of your equipment is contingent upon strict compliance with the operating conditions specified in this manual.
Operating Environment
External
It is most important to choose a cool, clean external operating environment.
Consideration of these factors should be a priority. Mount your ozone
generator in the best possible operating environment that is available at the
chosen site. If possible, mount in an area that is free of airborne moisture
particles.
Internal
Keep the inside of the generator chassis clean and dry. Dust particles and
condensation pose a challenge to the consistent operation of all ozone
generators. Make a note to inspect the internal cleanliness of the equipment
when you perform scheduled maintenance. For further information refer to
section 2.0.
Installation
The AIM PCS 200 is designed to be mounted vertically or horizontally on a wall, panel, or framework. There are three (3) keyhole mounting features within the chassis, sized for #8 screws. The use of wall anchors is recommended when stud(s) are not available. A minimum of six (6) inches clearance is required around the top, bottom and sides of the unit to ensure access and proper air flow. Choose a mounting location that permits power connection without the use of extension cords.
Operation
Ozotech, Inc., offers the AIM PCS 200 ozone generator with a variety of electrical input configurations to accommodate a wide range of applications. Configurations include a standard AC to DC wall transformer (included with purchase), a cigarette lighter adapter or twisted wire for connection to a hard 12 VDC source such as a car, boat or RV battery circuit. Most supply voltages fluctuate, so it is necessary to monitor your voltage and assure it is within acceptable variance values listed in section 4.0.
Your ozone generator is designed for simple and easy use.
- Connect your air preparation device to the air input tubing of the ozone generator.
- Connect your ozone output tubing, with inline check valve, to your appropriate ozone injection device.
- Connect power to the DC jack to turn on your ozone generator.
- Adjust and balance air flow using Ozotech’s ‘Venturi Calibration Guide’, available for download at www.ozotech.com/support.
Maintenance
The AIM series generators are delivered factory tested, calibrated, and adjusted for maximum efficiency and long life. Simple maintenance and appropriate operating conditions are the only requirements to keep the unit functioning withinb manufacturer’s specifications.
Performing any modifications or adjustments to internal components will cause the unit to function outside of manufacturer’s specifications and will cause damage to the unit not covered under terms of warranty.
Ozone Generator Maintenance
Frequency of Maintenance: Every 4800 hours or 6 months of operation:
CAUTION: Disconnect ozone generator from power supply before performing maintenance.
-
Remove the 4 press-in clips that secure cover and remove cover.
-
Clean or replace the Corona Discharge (CD) cells.
a. A CD cell cleaning kit may be purchased from Ozotech, Inc. Reference section 3.0 for more information.
b. Refer to section 5.1 for CD cell replacement. -
Clean interior and exterior of chassis.
-
Replace ozone resistant check valves on the air in or ozone gas outlet lines.
Spare/Replacement Parts
Part # | Description |
---|---|
33217-BR | Corona Discharge Cell* (1) |
47018-304 | Ozone Resistant In-line Check Valve* (2) |
40080-01 | Wall Transformer, 230/115 VAC to 12 VDC/2A |
47044-1 | CD Cell Maintenance Kit |
44140-1 | Ozone Resistant Tubing, 1/4” ID x 3/8” OD |
44077 | Clear PVC Tubing, 1/4” ID x 3/8” OD |
30078 | DI Dryer 2.0 (Desiccant indicating air dryer) |
(*) Denotes recommended spare maintenance parts with initial purchase. Followed by additional quantity, recommended for one year’s scheduled maintenance.
Specifications
Input Power Requirements:
- Operating Voltage (specified): 11.7 VDC to 13.9 VDC
- Power consumption: 600mA @ 12VDC (7.2 watts) nominal
- Product Size (L x W x H): 7” x 4.5” x 2”
- Shipping Weight: 2 lbs.
- Ozone Output: 220 mg/hr.
- Enclosure: Aluminum
Component Replacement
Electrical failure is usually the result of a mechanical failure. For example, should the CD cell become plugged with nitric byproducts or should water back into the cell, it could cause a catastrophic electrical failure. Proper air preparation can usually avoid the build-up of nitric byproducts.
CD Cell Replacement
Should a CD cell need to be replaced, refer to the following procedure and figure 3, in section 7.0.
CAUTION: Disconnect ozone generator from power supply before performing service.
- Remove the 4 screws that secure cover and remove cover.
- Pull the CD cell out of the retaining clips, then disconnect tubing and the high voltage wire connection.
- Reverse steps 1 & 2, reconnect power to the ozone generator, and return to service.
Troubleshooting Guide
System | Possible Cause | Solution |
---|---|---|
Unit doesn’t turn on | Unit is not connected to power source, or is connected | |
to improper power source | Refer to Input Power Requirements, section 4.0, for |
proper electrical r equirements
Red light on power supply will not illuminate| Improper outlet voltage| Verify
power at outlet
Damaged or defective power supply| Replace power supply
Unit turns on, but no ozone output| High voltage lead not connected to CD
cell.| Connect frequency driver HV lead to CD cell
Water has backed up into CD cell| Clean or replace CD cell.
Cell is plugged with nitric byproduct buildup or particulate matter| Clean or
replace CD cell. If not installed, install an air dryer onto ozone generator
air inlet
CD cell not seated in retaining clips| Re-install CD cell into retaining clips
Moisture in the inlet and/or outlet tubing Yellow discoloration in the outlet
tubing| Improper air preparation| In Install an air dryer onto ozone generator
air inlet
Nitric byproduct buildup in CD cell and/or tubing| Clean or replace CD cell
and/ or tubing
Water has backed up into the ozone unit| Failed or missing inline check valve
on ozone output tubing| Clean or replace CD cell. Replace or install new
inline check valve.
Illustrations
Figure 1. Typical well application w/contact tank and EOG filter
Figure 2. Typical well application w/EOG filter
Figure 3. AIM PCS 200 internal diagram
Limited Warranty
Ozotech, Inc., warrants, to the original purchaser, the A.I.M. series ozone generators to be free from defects in workmanship and material for (12) months from date of purchase. The corona discharge cell is warrantied against catastrophic electrical failure for (2) years from date of purchase. All parts, repaired or replacement, will be warranted only for the balance of the original warranty period. Ozotech, Inc.’s warranty obligation with regard to equipment not of its own manufacture is limited to the warranty actually extended to the Ozotech, Inc. by its supplier. Ozotech, Inc. will refund the purchase price, perform repairs or replace equipment, at the option of Ozotech, Inc.
The warranty shall be null, void, and non-binding upon Ozotech, Inc. if Ozotech, Inc. (or authorized service center) determines the cause of malfunction or defect to be a result of:
- Failure to perform proper maintenance as defined and recommended in this manual.
- Failure to adhere to and provide proper operating conditions, as defined in this manual, including operation outside of temperature range, operating in wet or dirty environment, operation outside of manufacturer’s specifications.
- Adjustments made by user other than product output flow rate within ranges specified by manufacturer.
Ozotech, Incorporated assumes no liability for damages incurred by deliberate or incidental misuse of this product, or damages incurred in transit.
Returns
If the need arises to return your equipment for service, the following procedure must be followed to ensure accurate and timely processing of repairs.
Obtain the serial number, model number and model name of unit to be returned.
Contact Ozotech, Inc. and request a Return Material Authorization (RMA) form. Make sure to give the factory representative an accurate and current shipping address.
Provide a description detailing the problem with the unit. Be as specific as possible.
After receipt of RMA form, package unit for shipment. Enclose the RMA form with the unit. Use the original packaging materials if possible. If not possible, please package the product to ensure against shipping damage.
Clearly write the RMA number on the outside of the shipping package.
Verify that the address is correct and current.
Shipments that are not factory authorized will be refused.
It is recommended that you ship with a reputable and reliable shipping company, and that the contents of the package are insured. Ozotech, Inc., accepts no responsibility for damage or loss of equipment in transit.
ALL FREIGHT CHARGES INTO THE FACTORY MUST BE PREPAID. If the repair is covered under warranty, the factory will pay return shipping charges (surface rates only) to the address listed on the RMA, within the continental United States.
If the repair is not covered under warranty, the returning party is responsible for payment of return shipping and handling charges, as well as labor and equipment costs associated with the repair.
OZOTECH, Inc. 1015 South Main Street, Yreka, CA 96097 Ph. 530.842.4189 ozotech.com
References
- Applied Ozone Technologies - Ozotech, Inc.
- Ozotech, Inc. – Applied Ozone Technologies
- Support – Ozotech, Inc.