TRANE Axiom GEHG Water Source Heat Pump User Guide
- June 10, 2024
- Trane
Table of Contents
TRANE Axiom GEHG Water Source Heat Pump
Product Information
The Water Source Heat Pump AxiomTM is a highly efficient heating and cooling system that utilizes water as its source. The product is manufactured by Trane and comes with various options for installation, including field-installed and factory-installed options. The product is available in different models, including GEVG006-024 and GEVG030-060, and can be used for Water Loop Heat Pump, Ground Water Heat Pump, and Ground Loop Heat Pump applications. The product’s performance meets the ANSI/AHRI/ASHRAE/ISO13256-1 standards.
Product Usage Instructions
- Before using the Water Source Heat Pump AxiomTM, ensure that it has been installed correctly and all the necessary options have been added. Refer to the user manual for installation instructions.
- The product can be used for heating and cooling purposes. Adjust the temperature settings according to your preference using the thermostats or zone sensors. The product comes with MERV 8 or 13 filters that should be replaced periodically to maintain the product’s efficiency.
- The product’s performance varies depending on the model and the application. Refer to Table 4, 5, and 6 in the user manual to determine the product’s water in/out size, condensate size, blower wheel size, unit size, compressor type, net weight, ship weight, filter size, rated GPM, capacity Btuh, EER, and COP.
- If you encounter any issues with the product, refer to the user manual for troubleshooting tips or contact Trane’s customer service for assistance.
Copyright
This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change.
Trademarks
All trademarks referenced in this document are the trademarks of their
respective owners.
Revision History
Updated Symbio™ 400-B to the document.
List of options
Factory Installed Options | Field Installed Options |
---|---|
1-inch or 2-inch Ducted Filter Rack | 2-inch or 4-inch Ducted Filter Rack |
Air-Fi® Wireless Communications | Ducted Panel |
Deluxe 24V, Symbio™ 400-B/UC400-B Controls | Hose Kits (or ship separate hoses |
and valves)
Factory-mounted Isolation Valve| Low, Medium and High Electric Heat
Hot Gas Reheat| Pump Module
Matte or Foil Face Insulation| Pump Module Hose Kit
MERV 8 or 13 Filters| Thermostats or Zone Sensors
Polymer or Stainless Steel IAQ Drain Pan| Waterside Economizer
Recessed Unit Mounted Disconnect Switch|
Standard or Deluxe Sound Package
General data – models GEHG006-024
Model GEHG | 006 | 009 | 012 | 015 | 018 | 024 |
---|---|---|---|---|---|---|
Unit size width x depth x height (in.) | 23 x 41 x 15.75 | 23 x 41 x 15.75 | 23 x | |||
41 x 15.75 | 25.5 x 46 x 17.75 | 25.5 x 46 x 17.75 | 25.5 x 49 x 18.75 | |||
Compressor type | Rotary | Rotary | Rotary | Rotary | Rotary | Scroll |
Net weight (lbs.) | 165 | 165 | 165 | 173 | 173 | 269 |
Ship weight (lbs.) | 255 | 255 | 255 | 297 | 297 | 393 |
Filter size nominal (in.) | 14 x 16 | 14 x 16 | 14 x 16 | 16 x 19 | 16 x 19 | 17 x |
20
Water in/out size (FPT)| 0.5| 0.5| 0.5| 0.5| 0.5| 0.75
Condensate size (NPTI)| 0.75| 0.75| 0.75| 0.75| 0.75| 0.75
Blower wheel Size (in.)| 9 x 6| 9 x 6| 9 x 6| 9 x 8| 9 x 8| 10 x 8
General data – models GEHG030-060
Model GEHG | 030 | 036 | 042 | 048 | 060 |
---|---|---|---|---|---|
Unit size width x depth x height (in.) | 25.5 x 49 x 18.75 | 25.5 x 55 x 19.75 | |||
25.5 x 55 x 19.75 | 28 x 68 x 21.75 | 28 x 68 x 21.75 | |||
Compressor type | Scroll | Scroll | Scroll | Scroll | Scroll |
Net weight (lbs.) | 269 | 313 | 313 | 381 | 394 |
Ship weight (lbs.) | 393 | 437 | 437 | 526 | 539 |
Filter size nominal (in.) | 17 x 20 | 18 x 23 | 18 x 23 | 20 x 30 | 20 x 30 |
Water in/out size (FPT) | 0.75 | 0.75 | 0.75 | 1.00 | 1.00 |
Condensate size (NPTI) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Blower wheel Size (in.) | 10 x 8 | 10 x 9 | 10 x 9 | 11 x 11 | 11 x 11 |
General data – models GEVG006-024
Model GEVG | 006 | 009 | 012 | 015 | 018 | 024 |
---|---|---|---|---|---|---|
Unit size width x depth x height (in.) | 19 x 19 x 30 | 19 x 19 x 30 | 19 x 19 x | |||
30 | 21.5 x 21.5 x 34 | 21.5 x 21.5 x 34 | 21.5 x 23 x 36 | |||
Compressor type | Rotary | Rotary | Rotary | Rotary | Rotary | Scroll |
Net weight (lbs.) | 149 | 149 | 149 | 155 | 157 | 210 |
Ship weight (lbs.) | 201 | 201 | 201 | 210 | 212 | 268 |
Filter size nominal (in.) | 14 x 16 | 14 x 16 | 14 x 16 | 16 x 19 | 16 x 19 | 16 x |
19
Model GEVG| 006| 009| 012| 015| 018| 024
---|---|---|---|---|---|---
Water in/out size (FPT)| 0.5| 0.5| 0.5| 0.5| 0.5| 0.75
Condensate size (NPTI)| 0.75| 0.75| 0.75| 0.75| 0.75| 0.75
Blower wheel Size (in.)| 9 x 6| 9 x 6| 9 x 6| 9 x 8| 9 x 8| 10 x 8
General data – models GEVG030-060
Model GEVG | 030 | 036 | 042 | 048 | 060 |
---|---|---|---|---|---|
Unit size width x depth x height (in.) | 21.5 x 23 x 36 | 21.5 x 26 x 38 | 21.5 x | ||
26 x 38 | 24 x 32.5 x 42 | 24 x 32.5 x 42 | |||
Compressor type | Scroll | Scroll | Scroll | Scroll | Scroll |
Net weight (lbs.) | 214 | 220 | 252 | 280 | 285 |
Ship weight (lbs.) | 272 | 280 | 312 | 343 | 348 |
Filter size nominal (in.) | 16 x 19 | 18 x 23 | 18 x 23 | 20 x 30 | 20 x 30 |
Water in/out size (FPT) | 0.75 | 0.75 | 0.75 | 1.00 | 1.00 |
Condensate size (NPTI) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Blower wheel Size (in.) | 10 x 8 | 10 x 9 | 10 x 9 | 11 x 11 | 11 x 11 |
ANSI/AHRI/ASHRAE/ISO13256-1 WLHP, GWHP and GLHP performance – 0.5 to 5 Tons
Model
|
Rated GPM
|
Rated CFM
| Water Loop Heat Pump| Ground Water Heat Pump| Ground Loop Heat
Pump
---|---|---|---|---|---
Cooling 86°F| Heating 68°F| Cooling 59°F| Heating 50°F|
Full Cool 77°F| Full Heat 32°F
Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
GEH/VG006| 1.50| 190| 7,000| 13.70| 9,300| 4.70| 8,100| 21.30| 7,500| 4.10|
7,400| 16.00| 5,600| 3.30
GEH/VG009| 2.25| 285| 8,700| 15.50| 11,200| 5.50| 9,600| 23.80| 9,100| 4.70|
8,900| 17.80| 6,700| 3.70
GEH/VG012| 3.00| 380| 11,400| 14.90| 15,300| 5.30| 13,300| 24.20| 12,400|
4.60| 12,100| 17.60| 9,400| 3.70
GEH/VG015| 3.75| 475| 14900| 15.3| 18700| 5.10| 16600| 23.00| 15400| 4.30|
15500| 17.40| 12300| 3.60
GEH/VG018| 4.50| 570| 17400| 15.6| 22200| 5.00| 19300| 23.50| 18400| 4.40|
18100| 17.70| 14300| 3.60
GEH/VG024| 6.00| 760| 23,900| 16.10| 31,100| 5.30| 26,600| 24.40| 25,300|
4.60| 24,800| 18.50| 19,600| 3.80
Model
|
Rated GPM
|
Rated CFM
| Water Loop Heat Pump| Ground Water Heat Pump| Ground Loop Heat
Pump
---|---|---|---|---|---
Cooling 86°F| Heating 68°F| Cooling 59°F| Heating 50°F|
Full Cool 77°F| Full Heat 32°F
Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
GEH/VG030| 7.50| 950| 29,000| 15.40| 37,900| 5.10| 32,300| 23.00| 30,800|
4.50| 30,200| 17.70| 23,300| 3.70
GEH/VG036| 9.00| 1140| 36,000| 15.40| 45,100| 5.00| 39,900| 22.60| 36,900|
4.40| 37,300| 17.60| 28,700| 3.60
GEH/VG042| 10.50| 1330| 40,900| 14.90| 55,600| 4.70| 45,500| 22.00| 45,600|
4.20| 42,600| 17.10| 35,300| 3.50
GEH/VG048| 12.00| 1520| 49,500| 15.10| 62,600| 4.90| 55,700| 22.80| 50,000|
4.20| 51,800| 17.40| 37,600| 3.30
GEH/VG060| 15.00| 1900| 55,200| 14.50| 75,400| 4.60| 61,700| 21.30| 61,200|
4.10| 57,300| 16.50| 47,000| 3.50
Notes:
- Rated in accordance with ANSI/AHRI/ASHRAE/ISO13256-1. Certified conditions are 80.6°F DB/66.2°F WB EAT in cooling and 68F DB/59°F WB EAT in heating.
- Models with capacities greater than 135,000 Btuh are not included in the ANSI/AHRI/ASHRAE/ISO13256-1 water-to-air and brine-to-air heat pump certification program.
Electrical data
*ECM motors – GE 0.5 to 5 tons**
Model No.| Unit Volts| Blower Motor HP| Minimum
Circuit Ampacity| Maximum Overcurrent Protective
Device
---|---|---|---|---
GEH/GEV006| 208-230/60/1| 1/3| 5/5| 15/15
GEH/GEV006| 265/60/1| 1/3| 5| 15
GEH/GEV009| 208-230/60/1| 1/3| 6/6| 15/15
GEH/GEV009| 265/60/1| 1/3| 5| 15
GEH/GEV012| 208-230/60/1| 1/3| 9/9| 15/15
GEH/GEV012| 265/60/1| 1/3| 7| 15
GEH/GEV015| 208-230/60/1| 1/3| 10/10| 15/15
GEH/GEV015| 265/60/1| 1/3| 7| 15
GEH/GEV018| 208-230/60/1| 1/3| 12/12| 20/20
GEH/GEV018| 265/60/1| 1/3| 10| 15
GEH/GEV024| 208-230/60/1| 1/2| 19/19| 30/30
GEH/GEV024| 265/60/1| 1/2| 13| 20
Model No.| Unit Volts| Blower Motor HP| Minimum
Circuit Ampacity| Maximum Overcurrent Protective
Device
---|---|---|---|---
GEH/GEV024| 208-230/60/3| 1/2| 11/11| 15/15
GEH/GEV024| 460/60/3| 1/2| 6| 15
GEH/GEV030| 208-230/60/1| 3/4| 20/20| 30/30
GEH/GEV030| 208-230/60/3| 3/4| 13/13| 20/20
GEH/GEV030| 265/60/1| 3/4| 16| 25
GEH/GEV030| 460/60/3| 3/4| 7| 15
GEH/GEV036| 208-230/60/1| 3/4| 24/24| 40/40
GEH/GEV036| 265/60/1| 3/4| 20| 30
GEH/GEV036| 208-230/60/3| 3/4| 16/16| 25/25
GEH/GEV036| 460/60/3| 3/4| 9| 15
GEH/GEV042| 208-230/60/1| 3/4| 26/26| 40/40
GEH/GEV042| 208-230/60/3| 3/4| 21/21| 30/30
GEH/GEV042| 460/60/3| 1| 10| 15
GEH/GEV048| 208-230/60/1| 1| 31/31| 50/50
GEH/GEV048| 208-230/60/3| 1| 23/23| 35/35
GEH/GEV048| 460/60/3| 1| 10| 15
GEH/GEV060| 208-230/60/1| 1| 38/38| 60/60
GEH/GEV060| 208-230/60/3| 1| 25/25| 40/40
GEH/GEV060| 460/60/3| 1| 13| 20
Clearances – GEVG 0.5 to 5 ton
- A 24-inch clearance from other mechanical and electrical equipment (where shown) is recommended for most unit configurations. This will enable panel removal from the unit for service/maintenance.
- The 24-inch side clearance on GEVG 0.5-5T models is for optimal access only. Side clearance is not a requirement as most components can be accessed from the front of the unit.
- A 1-inch minimum clearance between the filter rack and any obstacle is required for units in a free return application to provide proper air flow to the air-to-refrigerant coil. A 12-inch minimum clearance between the filter rack and any obstacle should be provided to properly attached ductwork.
- The 1-inch dimension shown in the back of the unit represents the supply duct collar for the back supply option. This clearance is needed to clear these flanges.
Clearances – GEHG 0.5 to 5 tons
A minimum 14–inch clearance for servicing the unit is required for all 0.5 to 5 tons configurations from other mechanical and electrical equipment (where shown) to enable panel removal from the unit for service/maintenance ability. The optimum clearance required is 20 inches.
Trane – by Trane Technologies (NYSE: TT), a global climate innovator – creates
comfortable, energy efficient indoor environments for commercial and
residential applications. For more information, please visit
trane.com or
tranetechnologies.com.
Trane has a policy of continuous product and product data improvement and
reserves the right to change design andspecifications without notice. We are
committed to using environmentally conscious print practices.
WSHP-PRC029D-EN 21 Jun 2023