FOREST LS-09-2021 Curtain Motor User Guide
- June 3, 2024
- FOREST
Table of Contents
STEPS TO SET THE LIMITS OF THE FMS MOTOR
LS-09-2021 Curtain Motor
STEP 1
Preferably set the limits of the motor with the motor in a hanging position.
Ensure that the Master Carriers of the system are in the open position,
meaning the intended position where you want the master carriers to stop when
the curtain is open.
STEP 2
-
Ensure that the two buttons on the bottom of the motor are visible, by removing the white cap of the motor (2A).
-
Ensure that the two colored wheels (on the photo depicted as white-red wheels) are in a neutral position. The position in which the indentations in each of the three wheels are in line. This is called the “zero situation” (2C). The motor comes standard with this setting.
-
Switch on the power
-
Press and turn one of the buttons to find out which button you need to set the masters in the closed or open position
-
Because you already moved the master to the open position you only have to select the setting wheel for the closed position
-
Press and turn the selected button until the masters have reached the intended ‘closed’ position.
-
Turn off the power. Press and turn the selected button again to set back the red-white-red wheels in the neutral position. You have set the limits now.
-
To save the settings put the safety clip in the middle position
STEP 5
Now close the system again and you will see that it stops automatically where
you have set the limits as described in step 3.
STEP 4
In order to check if the settings are correct, move the masters by using the
remote or the wall switch to the open and closed positions.
If, for example, the masters are not fully closing in the middle you have to
reset this position.