Features:
- Accurate, reliable, current measurement
- Measure Single-phase system
- True RMS measurement, can work in harmonic electric grid
- Input: AC voltage or current signal (Refer to instrument labels)
- Output: DC 4 ~ 20 mA, Analog signal (Refer to instrument labels)
- RS485 port optional
Technical Parameters:
Power Supply | AC 85~265V |
---|---|
Input | Current : 0~5A, 0~1A… |
Voltage: 0~100V, 0~400V…
Output| DC 4 ~ 20 mA, 0-20mA, 0-5V(refer to the label)
Accuracy| ≤ ±0.5%
Accuracy drift| Annual Variation < 0.2%
Response time| ≤ 400 ms
Isolation| Input / output / power supply
Power consumption| DC ≈ 3W, AC ≈ 4VA
Case Material| ABS fireproof materials
Insulation Voltage| AC 2KV RMS / min
Weight| About 250g
Insulation Resistance| Current output: 0<Lr<510Ω;
Voltage output: Lr>10KΩ
Dimension| 135 (L) X 23(W) X 92(H) mm
Installation| Fixed in a standard 35mm (1.38 inch) DIN rail
or screwed on the cabinet
Working Condition| 0 ~ 50 ℃/ less than 95% RH (Non-condensing)
Storage Conditions| -20 ~ 70℃/ less than 70% RH (Non-condensing)
Notes
- Pin 1,2 for power supply AC(DC)85-265V.
- Pin 6,8 for measurement signal input, Make sure the product parameters on the label are the same to your order, if not, please contact BLUE JAY sales team, sales@cqbluejay.com.
- For input AC signal, there is no polarity difference. For input DC signal, Pin8 for positive (+); Pin 6 for negative (-).
- Output signal for 4~20mA, access pin 4 for positive (+); Pin 5 for negative (-).
Output signal for 0~5V, access pin 11 for positive (+); Pin 5 for negative (-).
! Do read and full understanding of the controller wiring, if cannot sure the connection, please contact BLUE JAY technical support tech@cqbluejay.com for more help.
RS485 Communication
**Code:** | **Meaning:** | **Description:** |
---|---|---|
**FUNCTION 03** | **** Reading of n Words | ****_This function permits to |
read all the electrical parameters of the BJ194…series._
**FUNCTION 16| ** Preset Multiple Registers| ****Write value in to
the relevant register
Address| Data| Description| Byte| Instruction
2| point| Decimal point
position
| 4,5|
3| SIGN| Sign bit| 6,7| 1 for negative, 0 for plus
0| U/I| L-N value| 0,1|
1| PR| Frequency| 2,3
2| UC/UCA| C-phase volt| 4,5
For any inquiry about the instrument performance or whether any failure
happens, contact to Blue Jay’s technical service.