Scandia Warmbrite 140 Wood Fire and Gas Heater Owner’s Manual
- June 10, 2024
- SCANDIA
Table of Contents
- Scandia Warmbrite 140 Wood Fire and Gas Heater
- Product Information
- Features
- Council Requirements
- Product Usage Instructions
- Installation
- Operating
- Maintenance
- product Troubleshooting
- product Warranty
- SCANDIA WARMBRITE RANGE
- INTRODUCTION
- WOOD HEATER SAFETY
- BEFORE INSTALLING YOUR WOOD HEATER
- INSTALLATION
- OPERATING YOUR WOOD HEATER
- WOOD HEATER MAINTENANCE
- TROUBLESHOOTING
- WARRANTY
- SCANDIA WARMBRITE 140 EXPLODED DIAGRAM
- WARMBRITE 140 SPARE PARTS LIST
- SCANDIA WARMBRITE 200 SERIES 4 EXPLODED DIAGRAM
- WARMBRITE 200 SERIES 4 SPARE PARTS LIST
- SCANDIA WARMBRITE 300 SERIES 4 EXPLODED DIAGRAM
- WARMBRITE 300 SERIES 4 SPARE PARTS LIST
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Scandia Warmbrite 140 Wood Fire and Gas Heater
Product Information
Scandia Warmbrite Range
The Scandia Warmbrite Range consists of three models: Warmbrite 140, Warmbrite 200 S4, and Warmbrite 300 S4. These wood heaters are finely crafted and of high quality, designed to provide reliable performance when cared for properly. The range is manufactured by Scandia Group Pty Ltd in Australia and meets Australian standards and regulations.
Features
- Efficient heating through the burning of wood.
- Safety features to ensure safe operation.
- Quality construction and materials for durability.
- Available in three models to suit different heating needs.
Council Requirements
It is important to check local council regulations before installing and using the Scandia Warmbrite Range. A building permit may be required to install a solid fuel burning appliance. Alwaysconsult your local building inspector or council to determine what regulations apply in your area. The wood heater must be installed by a qualified person whose work conforms with local council regulations, Australian standards, and the manufacturer’s recommendations.
Product Usage Instructions
Scandia Warmbrite Range
Before using the Scandia Warmbrite Range, it is important to read and
understand all instructions provided in the user manual. Failure to do so may
result in damage to the product or injury to individuals.
Before Installing
- Check local council requirements for installing a solid fuel burning appliance.
- Ensure the wood heater is installed by a qualified person whose work conforms with local council regulations, Australian standards, and the manufacturer’s recommendations.
Installation
- Follow the installation guidelines presented in the user manual.
- Ensure the wood heater is installed in a well-ventilated area.
- Ensure the wood heater is installed with proper clearances to combustibles.
Operating
- Ensure the wood heater is properly maintained and operated according to the guidelines presented in the user manual.
- Supervise children to ensure that they do not play with the appliance.
- Never place combustible items such as furniture, fabric, or wood within the specified clearances to combustibles.
- Do not use the wood heater for any purpose other than that for which it is intended.
- Monitor the wood heater when in use and ensure it is extinguished properly when no longer needed.
Maintenance
- Clean the wood heater regularly according to the guidelines presented in the user manual.
- Check for damage or wear and replace any worn or damaged parts immediately.
product Troubleshooting
- If experiencing any issues with the Scandia Warmbrite Range, refer to the troubleshooting section of the user manual.
product Warranty
- The Scandia Warmbrite Range comes with a warranty. Refer to the warranty section of the user manual for details on what is covered and for how long.
Scandia Group Pty Ltd
- Head Office
- 58 Access Way,
- Carrum Downs VIC 3201
- Australia
- +61 3 8579 5900
- service@scandiastoves.com.au
- www.scandiastoves.com.au
Sc.WB.Version 1.5 30/11/22
Contents of manual may be updated without notice. For the latest version of
this manual please refer to our website:
www.scandiastoves.com.au
SCANDIA WARMBRITE RANGE
INTRODUCTION
Congratulations on purchasing a genuine Scandia Wood heater. When cared for properly, these high quality, finely crafted wood heaters will offer many years of reliable performance. This instruction manual has been developed to ensure optimum performance from your Scandia wood heater. It’s very important that you thoroughly read and understand all instructions before using your new wood heater.
COUNCIL REQUIREMENTS
Check Local Council Requirements E.g. permits When installing, operating and
maintaining your wood heater, follow the guidelines presented in these
instructions, and make them available to anyone using or servicing the wood
heater. Your city, town, state or territory may require a building permit to
install a solid fuel burning appliance. Always consult your local building
inspector or local council to determine what regulations apply in your area.
Please note:
Your wood heater must be installed by a qualified person whose work conforms
with local council regulations, Australian standards & manufacturers
recommendations. Failure to do so will void your warranty and could possibly
void any home insurance.
WOOD HEATER SAFETY
When properly maintained and operated your wood heater should give you many years of service, however there are important safety aspects of these products that you need to be aware of when operating a wood heater.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- If the electrical supply cord is damaged, it must be replaced by the manufacturer, it’s service agent or similarly qualified persons in order to avoid hazard.
- Never place combustible items such as but not limited to furniture, fabric or wood within the specified clearances to combustibles.
- The burning of wood gives off gases which can be extremely dangerous. Wood heaters are designed so that under normal operating circumstances these gases pass up the flue chimney system and cannot escape into your home, however it is important that your flue system is properly installed and that you check all joints regularly to ensure that there are no cracks or gaps, check the door sealing rope and replace when damaged/worn. We recommend a smoke alarm be fitted in rooms where wood heaters are installed. Do not use your wood heater in a room where negative pressure conditions exist. Negative pressure environments can cause products of combustion to be drawn from the fireplace into the room. Caution should be taken when using any form of extraction in a room where a wood heater is installed.
- This appliance is designed to specifically burn dry hardwood. Do not burn rubbish, driftwood, flammable liquids or any substance containing salts or corrosives.
- Creosote and soot may accumulate in your flue pipe and chimney. This may ignite, causing a chimney fire. If you suspect a chimney fire close down the air controls on the wood heater, if the fire persists evacuate people from the building and call the Fire Brigade. To prevent the accumulation of soot or creosote, check the flue and chimney regularly and clean as necessary. Good burning, hot wood heaters will generally cause a lot less build-up than slow burning wood heaters, likewise dry wood will cause less build-up than wet wood. We recommend a fire extinguisher be available where wood heaters are in operation. In the event of a chimney fire do not re-light the wood heater until the heater and the flue chimney system have been thoroughly checked and repaired/replaced as necessary.
- Wood heaters get extremely hot and should not be touched when lit. When young children are in the area, we recommend the use of a suitable fire guard around the wood heater. Always wear protective gloves when reloading wood heater.
- Never over-fire your wood heater. If external parts of your wood heater are glowing red then the wood heater is over-firing and your draught settings should be reduced. Never interfere with the draught mechanisms or adjust your air settings outside those limits set when the wood heater is manufactured. Never use a secondary fan to supply or extract air to the wood heater.
- All users of the wood heater should be aware of the contents of this manual. Please leave this manual where it is accessible to wood heater users and do not allow anyone to use the wood heater that is unfamiliar with its correct operation.
- Never use the wood heater if any parts are missing or damaged, only use genuine parts as replacements. Never modify your wood heater.
BEFORE INSTALLING YOUR WOOD HEATER
You need to consider the following to ensure the safe operation of your wood heater:
- Provision of adequate air to support efficient combustion of the fuel.
- A well sealed flue/chimney system, hereinafter referred to as the “flue system”.
- The protection of combustible materials in proximity of the wood heater.
- A suitable base on which to place your wood heater.
ADEQUATE PROVISION AIR
It is essential for the safe and efficient use of your wood heater that you
provide an adequate air supply to your wood heater. This may mean the
provision of an outside air supply to the room, especially if there are
extraction units such as cooker hoods or clothes dryers in the vicinity.
Failure to do so will mean that fuel is burned inefficiently causing smoke,
blackening the glass and may also cause smoke to come back into the room. As a
simple check for this open a door or window in the room and check if the wood
heater burns more efficiently.
WELL SEALED FLUE SYSTEM
Under no circumstances should you use aluminum or galvanized steel pipes for
your wood heater flue. Always fit pipes with the narrow crimped side down,
this allows any creosote to run down the inside of the pipe and not to come
out and cause an unsightly mess and possible fire hazard. Pipe bends should be
kept to a minimum and we do not recommend using more than 2 bends on any
installation. Flues must not pass through ceilings, floors, attics, roofs, or
combustible walls without adequate and approved insulation being provided to
protect combustible materials. The chimney and flue provide a means of taking
combusted fuel from the wood heater, as well as a draught to enable the wood
heater to work. It is essential that the flue system is kept in good condition
and there are no breaks or cracks allowing contact with any other combustible
materials of the house. It is also essential that the flue system is kept
clean and seals are maintained to ensure the draught is not lost. The open end
of the flue system must be above the height of the apex of the building and
any other obstructions, such as trees, which are within 3 meters (10ft) of the
flue system. Failure to do this will affect the efficiency of the wood heater
and may cause down draughts which will mean dangerous products of combustion
are emitted into the room. Under no circumstances should the flue pipe be less
than 6” (152mm) internal diameter.
CLEARANCES TO COMBUSTIBLES
It is extremely important that you respect required installation distances and
that you respect local installation regulations. This is for your safety! The
manufacturer is not responsible for the product, if it is not installed
following these recommendations. These clearances may only be reduced by means
approved by the regulatory authority. A combustible surface is anything that
can burn (i.e. plaster, wall paper, wood, fabrics etc.) These surfaces are not
limited to those that are visible and also include materials that are behind
non-combustible materials. If you are not sure of the combustible nature of a
material, consult your local fire officials.
HEARTH REQUIREMENTS
The floor protector must consist of 9mm thick cement fibre sheet which has a
thermal resistance of 0.008m2 K/W, per 4mm thickness or equivalent. Scandia
have a complete range of suitable ready to install hearth pads for straight
wall and corner installations.
INSTALLATION
CLEARANCES TO COMBUSTIBLES
All measurements are in ‘mm’
The above clearances are applicable when using the Scandia Decorative mesh
flue kit. (Decorative flue is fitted with an additional heat shield).All
Warmbrite 300 values applicable for Decorative Mesh and Solid Casing flues.
Manufacturers recommendation: Keep all combustible materials at least 1.22 metres (4 feet) away from the appliance. This include rugs, fabrics, furnishings, papers, firewood, etc. NEVER dry clothing on or within 1.22 meters of the appliance.
INSTALLATION ….continued
FOR CONNECTING INTO A STANDARD INSTALLATION USING SCANDIA FLUE KITS
The following drawing is meant as a guide only. Your wood heater must be
installed by a qualified person whose work conforms with local council
regulations, Australian/New Zealand standards (AS/NZS 2918:2018) &
manufacturers recommendations. Scandia wood heaters are independently tested
to Australian Standards using a Scandia flue kit, we always recommend using a
Scandia flue kit when installing a Scandia wood fire.
- Locate wood fire in it’s proposed position according to manufacturers recommendations.
- Use a plumb bob to mark the ceiling in line with the centre of the flue collar.
- Check that the outer casing will clear all combustible materials by 25mm. Determine positions of noggins to avoid cutting, otherwise headers must be installed for strength.
- Cut a 305mm diameter hole in the ceiling. Directly above cut a hole in the roof to accommodate outer casing.
- Fix the angle brackets to the joists so that the drop box (first length of located casing) is located in the centre of the hole.
- Position the drop box between the angle brackets, keeping a 25mm clearance to combustibles. The located end of the drop box must protrude no less than 150mm down from the ceiling or any combustible material. Fix the drop box to the angle brackets.
- Add the remaining casings to the required height. Australian/New Zealand Standards state that “the flue pipe shall extend not less than 4.6m above the top of the floor protector”. If the flue pipe is within 3 metres of the ridge, the flue pipe must protrude at least 600mm above the ridge of the roof. If the distance from the ridge is more than 3 metres, the flue pipe must protrude at least 1000mm above roof penetration. Additional lengths of casing and flue may be required to achieve this. The flue pipe must be more than 6 metres from any nearby structure. Other clearances may be applicable, it is up to the installer to ensure compliance with all regulations. See Figure 1 and 2 on P7.
- Install roof flashing (Additional accessory, not supplied in flue kit)
- Secure the Ceiling Collar in place using ceramic spacers and screws provided.
- Insert crimped end of the upper decorative flue (without internal stainless steel heat shield) up into the drop box. Then insert the crimped end of the lower decorative flue (with the internal stainless steel heat shield) up into bottom of the upper decorative flue. The lower decorative flue features locating tags on the non crimped end which rest on the heater flue collar. The solid heat shield section of the decorative mesh and stainless steel inner heat shield is to face the wall.
- Feed stainless steel flue through decorative flue and drop box through to the required height. Assemble flue pipes tight together as you go ensuring seams are straight. Secure each joint with three stainless steel rivets or screws spaced equally. Clean any finger prints or oils off stainless steel flue with methylated spirits.
- Trim the inner flue to the same height as the outer casing. Place cover cone and cowl over stainless steel flue & push cover cone over gal casing. Fix cover cone to gal casing with stainless steel pop rivets or screws.
FOR CONNECTING INTO EXISTING MASONRY CHIMNEY
Any chimney should be fully intact with no holes or missing bricks. We
recommend a chimney register be installed above any installation into a
masonry fireplace minimising heat loss up the chimney. The top of the chimney
must be sealed using a chimney plate which should be sealed in place with a
mortar mix. Active flue should be trimmed in line with the top of the chimney
if it meets the minimum height requirements under AS/NZS 2918. If additional
lengths are required to fulfill this requirement these lengths must be cased.
The flue should always be finished with a cowl and cone.
MINIMUM INSTALLATION CLEARANCES
FIREBOX ASSEMBLY
- Remove all loose items from the fire box. First install the top baffle. Place the baffle in the firebox with the bent edges facing the same direction as in the below drawings.
- Lift the front edge of the baffle up and rest it on the top of the front baffle support lugs, continue to lift the rear of the baffle over the rear lugs, you will need to slide the baffle forward to clear the rear lugs.
- Once the rear of the baffle is above the rear lugs slide the baffle all the way to the back of the firebox and rest the rear of the baffle on the rear lugs, ensuring the baffle is touching the rear wall of the firebox.
- Next install the firebricks. First install the side and rear firebricks, place the firebrick retainer in place on the top of the firebricks as shown in the below diagram.
- Install the base firebricks. Push side firebricks all together leaving any gap at the front of the heater. Push rear firebricks together leaving any gaps even on each side. Push base firebricks together leaving even gap around outside.
SCWB1402
- Top Baffle
- Firebrick Retainer
- Firebricks – 230mm x 121mm x 38mm – Qty 8
- Firebrick – 230mm x 121mm x 38mm with notch – Qty 1
- Firebrick – 183mm x 162mm x 25mm – Qty 4
SCWB2004
- Top Baffle
- Firebrick Retainer
- Firebricks – 200mm x 98mm x 25mm – Qty 9
- Firebrick – 200mm x 90mm x 25mm – Qty 2
- Firebrick – 218mm x 144mm x 25mm – Qty 4
SCWB3004
- Top Baffle
- Firebrick Retainer
- Firebricks – 200mm x 108mm x 25mm – Qty 11
- Firebrick – 200mm x 55mm x 25mm – Qty 2
- Firebrick -269mm x 116mm x 25mm – Qty 6
OPERATING YOUR WOOD HEATER
FAN OPERATION
- Step 1 Plug heater into a power outlet
- Step 2 Locate fan switch on pedestal
- Step 3 Adjust 3 speed fan as desired Excludes Warmbrite 140
CONTROLS AND THEIR USE
- Power cable for fan operation
- 3 Speed Fan switch
- Air Slide to control primary air intake
-
- Secondary Air Slide for use when lighting Warmbrite 140. Close 30 mins after fire is established.
-
FUEL
Your wood heater is designed to burn dry hardwood only. It is NOT designed to
burn the following:
- Soft wood
- Treated or painted wood
- Paper or cardboard, other than small amounts used to light stove.
- Plastics
- Synthetic fuel or logs that are not approved for solid fuel stoves
- Household rubbish
- Liquid fuels
Burning these or other products for which the wood heater was not designed may damage the wood heater and cause a fire hazard or release toxic fumes. Fuel should be stored in a dry place; wood should be dried for at least 1 year and have a moisture content of less than 20%. Wet wood may cause serious creosote build up, which may damage your flue system and even your wood heater. Therefore the use of green, sappy or wet wood is strongly discouraged.
WARNING: FIRST OPERATION OF STOVE
When operating, this unit will get extremely hot. Do Not Touch, use tools
where necessary. You should begin using your wood heater by lighting small
fires which get progressively larger. We recommend lighting approximately 5
small fires before you put the wood heater into full service. Allow the wood
heater to fully cool between each of these fires. There may be some smell and
a small amount of smoke from the wood heater during the initial operations.
This is perfectly normal and is merely the curing of the wood heater paint.
Opening a window or door to provide additional ventilation will help alleviate
this.
OPERATING YOUR WOOD HEATER ….continued
AIR CONTROLS
Your wood heater needs air to burn the fuel. This air is supplied through a
primary air slide at the right side of the front of your wood heater above the
door. On the Warmbrite 200 and 300 secondary air is drawn into the top rear of
the firebox which is not adjustable. Primary air, as the name suggests, is
used for the initial burning of the fuel and is also used to keep the stove
glass clean. Secondary air is used for secondary combustion, which makes the
stove more efficient and reduces emissions. The settings of the primary air
control very much depends on draught and local conditions and after a few
fires, you should have a good idea of the best settings for your wood heater.
The air slide control should be fully opened when lighting the fire. Once the
fire is established, the air slide control may be adjusted as required.
Reducing the air intake will cause the wood heater to burn slower. This may
cause some blackening of the stove glass, but this should burn off once the
wood heater is burning brightly again.
LIGHTING THE FIRE
Open the fire door, lay a few crumpled sheets of paper or firelighters on the
firebox base then a few small dry pieces of sticks or kindling. Open the air
inlet controls. Now light the paper, close the fire door when the kindling has
caught fire (allow about 10 minutes for this to happen) add larger pieces of
dry wood, until the fire box is half filled. When the larger pieces of wood
have caught fire, add full sized logs. Close the air controls to the point
where the required burn rate is obtained.
REFUELING
Before refueling your wood heater, turn the air supply to high for a few
moments until there is a good fire in the heater. This will ensure there is no
build-up of harmful gases in the wood heater when the door is opened and will
also get the new fuel burning quickly and not allow it to kill the fire. Open
the door slowly in case any logs or coal have fallen against the glass.
Opening the door quickly may result in smoke being drawn into the room.To
reload the wood heater, open the door and feed the fuel in slowly always using
either tongs, a small shovel along with protective gloves. Do not overfill the
wood heater. It is always better to put in small loads often rather than big
fills less frequently. Wood should be loaded in a front to back direction,
this helps air flow as well as reducing the risk of logs falling forward.
Close the door gently after wood heater is reloaded.
OVERNIGHT BURNING
Your wood heater is designed to maximise burn times. Best results are achieved
when you establish a good fuel bed in the wood heater and allow it to burn for
about 30 minutes before closing the air slide control fully. When you return
to your wood heater, fully open the air slide control until you have a good
fire and then set to normal operating levels. Do not add fuel until the fire
bed is hot and red. Then add a little for the first time and allow that to
ignite before adding more. During overnight burning, the wood heater glass may
blacken, but when a hot fire is established again this should burn off. Please
note: Warmbrite 140 does not support overnight burning due to the size of the
firebox.
WOOD HEATER MAINTENANCE
CHECK YOUR WOOD HEATER REGULARLY
Initially, we recommend you check your flue system at least once per month.
After the first few months you will notice a pattern of soot and creosote
build up and you can then determine an inspection interval for checking soot
and creosote build up that is suitable for your wood heater installation.
Other checks, as listed below, should be carried out at least twice per year.
If you notice anything wrong at any time it should be repaired immediately.
Never use a wood heater that is in any way damaged or has a damaged flue.
- Check your flue system for build up of soot or creosote and for signs of damage to joints.
- To check flue outlet remove top of baffle by lifting and pulling out at end. Use a flashlight to check flue outlet. Clean and repair as necessary. Always replace top baffle before relighting stove.
- Check that glass is not cracked or chipped and that the sealing rope is in good condition. Replace as necessary.
- When the room is dark, use a strong flashlight to check the sealing of the wood heater at the edge and corners for leaks. Any leaks or cracks found should be repaired with fire cement or damaged parts should be replaced with genuine spare parts.
- During periods in inactivity or infrequent use, regularly alternate the position of the flue damper. We also recommend placing a silica bag in the firebox to absorb any moisture which may cause rust.
- Check that wood heater door is tight and well sealed when closed. Place a strip of paper into the wood heater and close the door, try to pull out paper. You should feel some resistance to your pull, check several points around the door. If it pulls out too easily, replace the rope and seal in place with a suitable high temperature sealant.
- Check baffle plate and firebricks. Baffle plate should be replaced if a hole appears in the surface of the plate. Firebricks should be replaced when they start to crumble or the firebox is exposed.
WOOD HEATER MAINTENANCE ….continued
ASH REMOVAL
When the stove is out and completely cold you may remove the ash using an ash
vacuum or a steel bucket with a lid and shovel. Place a cover over the bucket
so that when removing the bucket the ash does not blow about your house.
CARE OF GLASS
At times, especially when the air controls are turned to low settings or when
damp wood is used, the wood heater glass will blacken. This is caused by fuel
that is not completely burnt, but the build-up on the inside of the glass will
normally burn off when a good hot fire is established in the wood heater.
There may be times however when you need to clean the glass. To do this, use a
soft cloth and a non-abrasive glass cleaner. Only ever clean the glass when
the wood heater is cold. For best results select from Scandia’s range of glass
cleaning products. When loading fuel into the wood heater, always make sure it
is not protruding out through the door opening, as this may break the glass
when you close the door. This is especially relevant when loading logs. Always
close the door gently. If the glass does crack when the wood heater is lit,
let the fire die out. Do not open the door until the wood heater has fully
cooled. Replace the glass with the specified replacement part before re-using
the wood heater.
DOOR ADJUSTMENTS
Door closing tension adjustment – As door seals age the seal beds into the
heater body, this will allow air to be drawn in any gaps created. Remove the
grub screw from the door handle shaft on the inside of the door, this will
allow the handle to rotate 360O. Rotate the handle 1 full turn anti-clockwise
and shut the door. Repeat this step until the door offers a little resistance
to close. Replace the grub screw. Over tightening may cause the door to
distort and break the glass. If the door is at maximum adjustment this
generally means the door seal will need replacing.
REPLACING PARTS
Always use genuine replacement parts. Only ever make replacements when the
wood heater is cold. All replacement parts can be ordered from
www.scandiastoves.com.au.
SURFACE FINISH
To clean your heater wipe lightly with a damp cloth or dust with a duster.
Some cleaning products may leave stains on the wood heater surface. Never use
abrasive cloths as these may scratch the surface; take caution when using
microfiber cloths as they can leave swirl marks if used in a circular motion.
Painted wood heaters can be re-painted by using a good quality, high
temperature wood heater paint. When re-painting, make sure there is plenty of
ventilation and follow the manufacturer’s instructions. Allow the paint to
fully dry before lighting the stove and allow extra ventilation for the first
couple of fires as some fumes may emit from the stove as the paint cures.
Scandia high temp enamel is available at your local Scandia retailer. Visit
www.scandiastoves.com.au for details.
TROUBLESHOOTING
Many people underestimate the importance of using a professional installer with experience in wood heating who adheres to Australian Standards to install their wood fire. If you are having issues with your wood fire not working the way you think it should, we implore you to speak to your installer first; they can help you with issues such as burning too much or too little wood, smoke in the room when you open the door, blackened glass or build-up of creosote during use. A professional installer can also provide guidance on whether the problem is a manufacturing issue in this instance we will work with them to resolve any issues as soon as possible for you. It is important to remember that all flue installations must be compliant with Australian Standards. A heater installed with a non-compliant flue configuration will not perform as advertised or as tested.
FIRE NOT BURNING
A wood heater not burning is generally caused by either a shortage of air
and/or incorrect or damp fuel. If fuel is not the problem check:
- That the air controls are opened.
- There is no blockage in the flue system.
- That the open end of the flue is above the height of any nearby obstructions.
- That there is a sufficient air supply into the room and that this supply is not being taken by an extractor fan.
GLASS BLACKENS
Glass usually blackens when:
- The fuel is not being burned efficiently because of starvation of air.
- Bad quality or damp fuel is being used.
Please note: For optimum efficiency always use a good quality dry hardwood.
SMOKE IN ROOM
If the wood heater is properly installed it should not emit any smoke into
your room. Should this happen, check that your room is not air tight. This can
easily be checked by opening a door or window. If the smoking stops you need
to provide an additional air supply into the room. If this is not the problem,
check if your chimney is blocked or obstructed and that you are not getting a
down draught caused by the location of the open end of the flue pipe or
chimney. If the problem persists contact your installation company and ask
them to get your chimney and stove installation checked.
FIRE BURNING TOO QUICKLY
This is usually caused by too much draught or air.
- Firstly try reducing the air supply to the wood heater by closing down your air controls, if this fails then you may have to adjust the door or you may have damage to the sealing.
- Close a thin strip of paper in the door, check to see if the paper stays in place or pulls out. If the paper pulls out easily you may need to adjust or replace the door seal.
- Check to see if the glass moves within the door frame. If it does you may need to tighten the glass retainer screws.
- Check the condition of the door sealing rope and the glass seal tape.
See video at:https://www.youtube.com/watch?v=nT-V_zL4jeg
CHIMNEY FIRE
Chimney fires occur when soot and creosote that have built up in the flue
system ignite. If the wood heater is operated properly and the flue checked
and cleaned regularly then chimney fires should not occur. These fires can be
very dangerous and must be avoided. Try to maintain good, hot fires in the
wood heater whenever possible and at least once in every firing open the air
controls and allow the wood heater to burn on full for a short while until the
entire fire bed is glowing red. Check your flue system regularly for build-up
of soot and creosote and clean as necessary. Chimney fires can be detected by
sparks coming from the top of the chimney, a roaring sound coming from the
area of the stove or chimney or vibration in the stove or chimney. In the
event of a chimney fire, close the air controls, evacuate the building and
call the fire department. Do not relight the stove after a chimney fire until
the stove and flue have been checked and any necessary repairs have been
carried out.
WARRANTY
SCANDIA LIMITED WARRANTY
This limited warranty is given by Scandia Heating (Aust) Pty Ltd (ACN 005 868
093) (Scandia or we) to the original retail purchaser (you) of the wood heater
to which this Warranty applies. Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does
not amount to a major failure. The benefits that this Warranty provides are in
addition to other rights and remedies available to you under the Australian
Consumer Law. This Warranty does not limit those rights and remedies.
SCOPE OF WARRANTY
If a defect in material or workmanship appears in the following parts within
the corresponding warranty period after the date of the original purchase,
such as to make the wood heater unfit for normal home use; and you comply with
the requirements below regarding making a claim, then, subject to the
exclusions below, we will replace or repair the relevant part or (at our
option) replace the entire wood heater with the same or comparable model
.
To the extent permitted by law, our liability under this Warranty is limited to this replacement or repair obligation.
IMPORTANT
For this Warranty to apply, you must fully complete the Warranty Registration
Form via
scandiastoves.com.au/warranty.
Alternatively you can complete the Warranty Registration Card and mail it to
our mail address (below) within 30 days after the original purchase. By
completing this form, you also agree that, to the extent permitted by law, our
liability to you on any basis in relation to the wood heater (other than under
the Australian Consumer Law) is limited to our obligations under this
Warranty.
EXCLUSIONS
This Warranty does not apply:
- Where the defect is not due to the original design or manufacture of the part (including where the wood heater, part or accessory has been subject to accident, abuse, alteration, misuse or neglect or has been installed, inspected, operated or maintained negligently or not in accordance with applicable local laws and regulations and the manufacturer’s printed instructions, if any)
- Where the firebricks, top baffle or fibreglass seal have not been replaced after becoming damaged or worn
- To any accessories or optional parts
- To any glass, paint, firebrick, fibreglass seal sold or used with the wood heater
- To any surface rust which may occur in transit, storage or use. This includes installations in close proximity to coastal areas and salt water which may cause rust to the appliance.
HOW TO MAKE A CLAIM
Any claim under this Warranty must be in writing to our mail address below. It
must be sent within the applicable warranty period and must state:
- The model and serial number of the wood heater
- The place, price and date of purchase
- Reasonable details of the defect
To obtain replacement or repair under this Warranty, the wood heater must be returned to the original place of purchase (and collected from there once the replacement or repair is complete) at your cost. Scandia will not be responsible for anyassociated freight, disconnection or re-installation costs (including labour costs). Scandia will only be responsible for transport of the wood heater from the original place of purchase to Scandia’s premises (and back), and replacement or repair in accordance with this Warranty.
REGISTER YOUR PRODUCT
REGISTER ONLINE Register your product warranty online by visiting: www.scandiastoves.com.au/warranty Your data will be used by Scandia to provide you with information about your purchase upon request.
REGISTER BY MAIL
Alternatively, please complete the attached warranty card within 30 days of
installation and return to: Scandia Group Pty Ltd.58 Access Way, Carrum Downs
Victoria, Australia, 3201.
SCANDIA WARMBRITE 140 EXPLODED DIAGRAM
WARMBRITE 140 SPARE PARTS LIST
LEGEND | PART | QTY | SCANDIA PART NO. |
---|---|---|---|
1 | Main body | 1 | SP14001 |
2 | Rear heat shield | 1 | SP14010 |
3 | Door frame | 1 | SP14011 |
4 | Air slide spring handle | 2 | SP00010 |
5 | Door handle shaft | 1 | SP14016 |
6 | Door handle | 1 | SP14013 |
7 | Door handle spring | 1 | SP00008 |
8 | Air slide | 1 | SP14014 |
9 | Door glass | 1 | SP14009 |
10 | Glass retainer | 2 | SP14015 |
11 | Firebrick set | 1 | SP14008 |
12 | Firebrick retainer | 1 | SP14007 |
13 | Door latch | 1 | SP00020 |
14 | Baffle | 1 | SP14017 |
SCANDIA WARMBRITE 200 SERIES 4 EXPLODED DIAGRAM
WARMBRITE 200 SERIES 4 SPARE PARTS LIST
LEGEND | SCANDIA PART NUMBER | DESCRIPTION | QTY. |
---|---|---|---|
1 | SG030700724 | SCANDIA, WARMBRITE 200, SIERIES 4, PEDESTAL & FIREBOX ASSY | 1 |
2 | SG030700725 | SCANDIA, WB200, S4, ROOM AIR DEFLECTOR | 1 |
3 | SG030700726 | SCANDIA, WB200, S4, HEAT SHEILD, RHS | 1 |
4 | SG030700727 | SCANDIA, WB200, S4, HEAT SHEILD, REAR | 1 |
5 | SG030700729 | WB200, S4, AIRSLIDE | 1 |
6 | SG030700730 | WB200, S4, ASH LIP | 1 |
7 | SG030700731 | WB200, S4, BAFFLE PLATE | 1 |
8 | SG030700732 | SCANDIA, WB200, S4, HEATER TOP PLATE | 1 |
9 | SG030700733 | SCANDIA, WB200, S4, PEDESTAL FRONT COVER | 1 |
10 | SG030700734 | WB200, S4, FIRBRICK RETAINER | 1 |
11 | SP00012 | Warmbrite Fan Switch Series 2 | 1 |
12 | SP00011 | FAN SWITCH KNOB, WARMBRITE | 1 |
13 | SG030700735 | SCANDIA, WARMBRITE, DOOR HINGE | 1 |
14 | SG030700784 | WB200, S4, DOOR ASSY | 1 |
15 | SG030700728 | SCANDIA, WB200, S4, HEAT SHEILD, LHS | 1 |
16 | SG030700736 | WB200, S4, TOP DECORATIVE PANEL | 1 |
17 | SG030700737 | SCANDIA, WB200, S4, LOWER DECORATIVE PANEL | 1 |
18 | SP00010 | AIRSLIDE, SPRING HANDLE, SUIT DIA 6MM ROD. | 1 |
19 | SG031300118 | Kit Fasteners Air Slide | 2 |
20 | SG030600018 | FIREBRICK SET WARMBRITE 200/KA500 | 1 |
21 | SG030700740 | WARMBRITE, S4, DOOR LATCH | 1 |
22 | SP00004 | Rubber Capped Bolt M5 | 4 |
23 | SG030800045 | ROOM FAN ASSY, OPTION LIST | 1 |
24 | SG030700806 | WARMBRITE, FAN MOUNT BRACKET | 1 |
WARMBRITE 200 SERIES 4 DOOR ASSEMBLY LIST
LEGEND | SCANDIA PART NUMBER | DESCRIPTION | QTY. |
---|---|---|---|
1 | SG030700786 | WB200, S4, DOOR FRAME | 1 |
2 | SG030700785 | WB200, S4, DOOR SEAL & GLASS RETAINER FRAME | 1 |
3 | SG031000144 | WARMBRITE, 200, S4, DOOR GLASS | 1 |
4 | SG030700787 | WB RANGE, S4, DOOR HANDLE BUSH | 1 |
5 | SP00008 | Handle Spring Warmbrite Chrome | 1 |
6 | SG030400024 | 7×3 Glass Rope Seal Warmbrite 200 S4, | 1 |
7 | SG030700788 | WB RANGE, S4, DOOR HANDLE | 1 |
SCANDIA WARMBRITE 300 SERIES 4 EXPLODED DIAGRAM
WARMBRITE 300 SERIES 4 SPARE PARTS LIST
LEGEND | SCANDIA PART NUMBER | DESCRIPTION | QTY. |
---|---|---|---|
1 | SG030700791 | WB300, S4, FIREBOX & PEDESTAL | 1 |
2 | SG030700792 | WB300, S4, ROOM AIR DEFLECTOR | 1 |
3 | SG030700793 | WB300, S4, HEAT SHEILD, RHS | 1 |
4 | SG030700794 | WB300, S4, HEAT SHEILD, REAR | 1 |
5 | SG030700815 | WB300, S4, AIRSLIDE | 1 |
6 | SG030700796 | WB300, S4, ASH LIP | 1 |
7 | SG030700797 | WB300, S4, BAFFLE PLATE | 1 |
8 | SP00004 | Rubber Capped Bolt M5 | 4 |
9 | SG030700798 | WB300, S4, HEATER TOP PLATE | 1 |
10 | SG030700799 | WB300, S4, PEDESTAL FRONT COVER | 1 |
11 | SG030700800 | WB300, S4, FIRBRICK RETAINER | 1 |
12 | SP00012 | Warmbrite Fan Switch Series 2 | 1 |
13 | SP00011 | FAN SWITCH KNOB, WARMBRITE | 1 |
14 | SG030700735 | SCANDIA, WARMBRITE, DOOR HINGE | 1 |
15 | SG030700803 | WB300, S4, DOOR ASSY | 1 |
16 | SG030700795 | WB300, S4, HEAT SHEILD, LHS | 1 |
17 | SG030700801 | WB300, S4, TOP DECORATIVE PANEL | 1 |
18 | SG030700802 | WB300, S4, LOWER DECORATIVE PANEL | 1 |
19 | SG031300118 | Kit Fasteners Air Slide | 2 |
20 | SG030600021 | Set Firebrick Warmbrite 300/KA600C/KA600i | 1 |
21 | SG030800045 | ROOM FAN ASSY, OPTION LIST | 1 |
22 | SP00010 | AIRSLIDE, SPRING HANDLE, SUIT DIA 6MM ROD. | 1 |
23 | SG030700740 | WARMBRITE, S4, DOOR LATCH | 1 |
24 | SG030700806 | WARMBRITE, FAN MOUNT BRACKET | 1 |
WARMBRITE 300 SERIES 4 DOOR ASSEMBLY LIST
LEGEND | SCANDIA PART NUMBER | DESCRIPTION | QTY. |
---|---|---|---|
1 | SG030700804 | WB300, S4, DOOR FRAME | 1 |
2 | SG030700805 | WB300, S4, DOOR SEAL & GLASS RETAINER FRAME | 1 |
3 | SG031000145 | WARMBRITE, 300, S4, DOOR GLASS | 1 |
4 | SG030700788 | WB RANGE, S4, DOOR HANDLE | 1 |
5 | SP00008 | Handle Spring Warmbrite Chrome | 1 |
6 | SG030700787 | WB RANGE, S4, DOOR HANDLE BUSH | 1 |
7 | SG030400025 | 7×3 Glass Rope Seal Warmbrite 300 S4, | 1 |
Head Office
58 Access Way, Carrum Downs VIC 3201 Australia
Scandia Group Pty Ltd
References
- Warranties | Scandia Wood Fire and Gas Heating
- Scandia Wood Fire and Gas Heating
- Warranties | Scandia Wood Fire and Gas Heating