WARNINGS AND CAUTIONS
IMPORTANT SAFETY INFORMATION
Please read these instructions carefully prior to starting up the unit!
The water system on which the operation of this product is based requires
utmost care and maintenance, possibly also the use of chemicals, in order to
prevent and keep the occurrence of micro-organisms and harmful bacteria,
especially legionellae that are responsible for legionnaire’s disease, under
control. Non-observance of this information about correct maintenance and care
can entail the spreading of harmful bacteria. Due to the fact that for
decorative purposes, water nozzles distribute water in the air, water droplets
containing harmful bacteria can enter your lungs and cause life-threatening
diseases. It is the responsibility of the owner of the water system and its
attendant units to ensure their maintenance and care in compliance with the
laws, directives and instructions laid down for this purpose. In order to
avert harmful contamination, we urgently recommend the user to ensure cleaning
and care of the water system and the water feature including the nozzle, and
to take all necessary measures to maintain the technical units, such as pumps,
tubing, connectors, underwater lighting, and nozzles to keep them in
functional order in line with safety aspects. However, the maintenance and
care obligation is not limited to the technical products supplied, but
encompasses the entire system.
We also recommend the owner to keep records of the dates when maintenance and
care was carried out, and to document all water tests made in conjunction with
the water feature. The owner is solely responsible for guaranteeing the safety
of the water feature. Use or maintenance of the units sold and the system are
beyond GeoGlobal Partner’s influence. GeoGlobal Partners can only be held
liable for manufacturing faults of TotalPond® units.
WARNING
- Risk of electrical shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Do not exceed the voltage shown on the pump.
- Always disconnect pump from the power source before beginning any maintenance or work on the pump.
- Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if damage is found.
- Do not remove the grounding pin from the power cord plug.
- Risk of electrical shock – This pump has not been investigated for use in swimming pool or marine areas.
CAUTION
- This pump has been evaluated for use with fresh water only.
- Use a proper power source as indicated on the pump label.
- Keep the cord away from high temperatures or other heat sources.
- Do not pump heated liquids.
- Do not let the pump run dry. Pump must be completely submerged for proper operation and cooling.
- Operate in freshwater only. Avoid heavily chlorinated water and water with high pH levels.
- Do not lift the pump by its power cord.
PREPARATION
Before beginning assembly or operation of product, make sure all parts are present. Compare parts with package contents list and diagram. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact Customer Care for replacement parts.
- Estimated Assembly Time: 15 minutes
- No tools required for assembly.
PACKAGE CONTENTS
Part | Description | Qty |
---|---|---|
A | Filter Box Lid | 1 |
B | Filter Box Bottom | 1 |
C | Coarse Filter Pad | 1 |
D | Fine Filter Pad | 1 |
E | Bioballs | 10 |
F | Fountain nozzle | 1 |
G | Diverter Valve | 1 |
--- | --- | --- |
H | Extension Tube | 2 |
I | Pump | 1 |
J | Coupler | 1 |
K | Swivel Adaptor | 1 |
L | Adapter for 3/4 in. Outlets | 1 |
OPERATION INSTRUCTIONS
-
Step 1: Place your pump inside the filter box close to the center with the pump outlet facing up. Route the pump power cord through the grove on the back corner of the filter box.
-
Step 2: Place bioballs around the pump.
-
Step 3: Connect the extension tube to the outlet of the pump using the supplied adapters.
-
Step 4: Tighten the locking nut for a secure fit.
-
Step 5: Place the fine filter pad (blue) over the bioballs and pump and add the course filter pad (black) on top.
-
Step 6: Place the lid over the box. It should snap closed.
This kit includes a coupler and a diverter valve. To flow water to the fountain nozzle only, proceed to step 7. To flow water to the fountain nozzle and a spitter, skip to step 10. -
Step 7: Connect the two extension tubes with the coupler. ****
-
Step 8: Connect the fountain nozzle to the top of the extension tube
-
Step 9: Place the assembled filter kit in water, and skip to step 14.
-
Step 10: Connect the extension tubes to the diverter valve. Make sure the arrow is pointing up and the diverter valve is connected as shown.
-
Step 11: For the use of the diverter valve, connect 1/2 in.
ID tubing onto the outlet of the diverter valve. Connect the other end of
tubing to a water feature.
NOTE: Tubing and water feature are not included.
- Step 12: Connect the fountain nozzle to the top of the extension tube.
- Step 13: Place the assembled filter kit in water.
- Step 14: Utilize the pivoting base to achieve a more vertical fountain display if needed.
- Step 15: Connect the pump into a properly grounded electrical outlet.
NOTE: If the diverter valve was used, you can adjust the flow control as needed.
SPECIFICATIONS
Max Flow Rate 338 GPH (at 0 ft.)
Waterspray effect, H x W max. 2.3 ft. x 1.6 ft.
Power Consumption 23 watts / 0.4 amps
Cord Length 16 ft.
Register your product online!
Use your smartphone camera
to scan the QR code or visit our website
totalpond.com/register
MAINTENANCE & TROUBLESHOOTING
Always disconnect units from the power source before beginning any maintenance or work on the unit.
FILTER
- The filter may require cleaning from time to time for optimal performance.
- The exterior surface of the filter box may need occasional cleaning. Particularly if the openings in the top of the filter box are obstructed. When cleaning the filter box use warm water only. Do not use any chemicals that may destroy the beneficial bacteria.
- Remove the filter pads and clean with water and when they are visibly soiled. For best results, clean the filter pads weekly.
- Filter pads should be replaced annually or when visibly deteriorating. Use Replacement Filter Pads #52233.
- The bioballs contain beneficial bacteria. At least once a year the entire system should be disassembled and cleaned thoroughly using warm water. This should not be done during the warm season as it may take up to 8 weeks to re-establish the environmental balance. The best time of the year to “breakdown” your system is in early spring before the water temperatures begin to rise.
- Put all media back into the filter and reconnect the pump to the power source when you are finished.
PUMP
Regular cleaning of the pump may be necessary depending upon the environment
in which it is operated. Clean the pump when it is visibly soiled or when a
drop in performance is detected.
-
Step 1: Before cleaning, always disconnect the pump from the power source and remove the pump cover.
-
Step 2: Remove the impeller cover to expose the impeller assembly. Remove the impeller assembly by gently pulling on the impeller blades. The impeller is held in place by a magnet.
-
Step 3: Use a soft cloth or brush and warm water to clean the impeller and the inside of the impeller housing.
- Step 4: Reassemble all pump parts and place in water before reconnecting to the power source.
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
- Check to make sure the power cord is plugged in and the pump is getting power.
- Check the pump outlet and any tubing, fountains, spitters etc. for kinks or obstructions.
- Remove the front cover and/or pump cover, and impeller cover to expose the impeller. Turn the impeller to ensure that it is not broken or jammed.
IF THE PERFORMANCE OF THE PUMP IS NOT SATISFACTORY OR THE PUMP DOES NOT FLOW EVENLY:
- Check to make sure the pump is completely submerged in water
- Check to make sure the impeller and the impeller housing are clean.
- Adjust flow control.
For product maintenance videos visit totalpond.com
REPLACEMENT PARTS
Visit our website: totalpond.com/replacement-parts
or contact Customer Care Monday – Friday
1-888-412-6001
customercare@totalpond.com
WARRANTY
1 Year Warranty
LIMITED WARRANTY
All pumps and electrical products are warrantied to the user against defective
material and workmanship, under normal working conditions. This warranty
period begins on the date of purchase by the original purchaser.
APPLICATION
Warranty covers only properly installed and maintained units. Any damage or
modification to the cord or to the unit will terminate the warranty. Pump
warranty is limited to applications pumping fresh water in a pond or fountain
only. Other liquid applications or extreme temperature uses must be approved
in writing by the manufacturer. Receipt and product date code are required for
warranty claims.
WARRANTY CLAIM
Warranty claims must be made by calling Customer Care (at
1-888-412-6001). If the item is
determined to be defective, you will be given authorization to return the
defective part(s), freight pre-paid, along with proof of purchase.
DISPOSITION
The manufacturer will make a good faith effort for prompt disposition
regarding all warranty claims. Returned product will be inspected to determine
cause of failure before warranty is applied. Warranty does not cover any costs
associated with the shipping, handling, installation or removal of products or
parts subject to this warranty. For products damaged in transit, a claim
should be filed with the carrier.
DISCLAIMER
Any oral statements made about the product by the seller, the manufacturer,
the representatives, or any other parties do not constitute warranties, should
not be relied upon by the user, and are not part of the contract for sale. The
seller’s and manufacturer’s only obligation, and buyer’s only remedy shall be
for the manufacturer to either replace and/or repair at the manufacturer’s
sole discretion, the product as described above. Neither seller nor the
manufacturer shall be liable for injury, loss or damages for lost profits,
lost sales, injury to person or property, or any other incidental or
consequential loss arising from any cause whatsoever, no matter whether based
upon warranty, contract, negligence or other misuse, and the buyer and user
agree that no other remedy shall be available to them. Before using, the buyer
and user shall determine the suitability of the product for the intended use,
and assume all risk and liability whatsoever in connection therewith. The
warranty and remedy described in this limited warranty is an exclusive
warranty and remedy in lieu of any other warranty or remedy expressed or
implied. All other warranties and remedies are hereby expressly excluded,
including but not limited to any implied warranty or merchantability of
fitness for any particular purpose. This warranty gives the buyer and user
specific legal rights, and buyer and user may also have other rights which
vary from state to state. Some states do not allow exclusioinis or limitations
of incidental or consequential damages, so the above limitations or exclusions
may not apply to you.
References
- TotalPond Water Gardening
- Register – TotalPond
- Replacement Parts – TotalPond
- TotalPond Water Gardening
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>