safetrust 8845-100 IoT Sensor Mullion User Guide

June 10, 2024
safetrust


8845-100 Quickstart Guide
Last Updated: March 202

In the box

| #6-32 x .375” spanner security screw
Option 1: Secures the top
and bottom casing together
---|---
| Nylon wall plugs
Used to brace the
screws inside the wall
| #6-32 x .375” phillips flat head screw
Option 2: Secures the top
and bottom casing together
| Sheet metal screw
SCR PTP, 2X6MM BLUE, ZINC CR3
For mounting to wall

What you’ll need

  • A working internet connection
  • Cable, 5-12 conductor (Wiegand), 4 conductor Twisted Pair Over-All Shield and UL approved, Belden3107A or equivalent (OSDP)
  • Linear DC power supply
  • Metal or plastic junction box
  • Drill with various bits for mounting hardwar

Installation

safetrust 8845-100 IoT Sensor Mullion - insert 3For a wall mounted installation, begin by pre-drilling your holes and insert the nylon screw plugs provided to support the weight of the reader. Once secured to the wall, you can fix the black plate to the wall using the screws (SCR PTP, 2X6MM BLUE, ZINC CR3) provided. safetrust 8845-100 IoT Sensor Mullion -
Wire Colors

The next step is to connect the wires as per the wiring table above. safetrust 8845-100 IoT Sensor Mullion - casingOnce the back plate has been fitted and the wiring is complete, the top casing can be inserted onto the bottom casing like shown above. safetrust 8845-100 IoT
Sensor Mullion - hardwareComplete the hardware installation by fixing either the snake eye screw (SMF #632X5/16″ SS) or a Phillips screw (SMF #6-32X5/16″ SS) to bottom casing.

Configuration

safetrust 8845-100 IoT Sensor Mullion - Safetrust

Open the Safetrust Wallet APP and select Manage Sensor tab. Make sure your system admin has set you up with this role.safetrust 8845-100 IoT Sensor
Mullion - App,

With the Admin Installer tab open from the App, bring the phone in range of the IoT Sensor and once visible from the App, highlight and select “Configure”.safetrust 8845-100 IoT Sensor Mullion -
Identity

  • Choose an Identity System.
  • Specify the Type of access from the dropdown (eg. Door, Gate etc.)
  • Assign a short Name and Description using alphanumeric characters.
  • Choose an Output for the sensor (the default is set to Wiegand).

safetrust 8845-100 IoT Sensor Mullion - SensorWhen the IoT Sensor information is saved successfully to Credential Manager and assigned to the Identity System, the new description will appear in the Manage Sensor tab with a unique serial number assigned.

Testing

safetrust 8845-100 IoT Sensor Mullion - Access with
cardssafetrust 8845-100 IoT Sensor Mullion -
mobile

Regulatory Information

FCC: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Canada Radio Certification: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
CE Marking: Safetrust hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

 Support

hank you for purchasing the Safetrust IoT Sensor Mullion.
Support
If for any reason you need assistance with your installation, please contact your local Sales representative

  www.safetrust.com/support
Safetrust Inc. | safetrust.com
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

safetrust User Manuals

Related Manuals