safetrust SA530 IoT Sensor Keypad User Guide

June 4, 2024
safetrust

safetrust SA530 IoT Sensor Keypad User Guide

01. In the box

FIG 1 In the box.JPG

02. What you’ll need

  • A working internet connection
  • Cable, 5-12 conductor (Wiegand), 4 conductor Twisted Pair Over-All Shield and
  • UL approved, Belden3107A or equivalent (OSDP)
  • Linear DC power supply
  • Metal or plastic junction box
  • Drill with various bits for mounting hardware

3. Installation

FIG 2 Installation.JPG

For a wall mounted installation, locate the electrical box which will be recessed into the wall. You will see a top and bottom metal flange with holes which is used to secure the back plate to the wall. Using the Phillips machine screws provided (#6- 32 x .375”) screw the back plate against electrical box so that it’s flush.

FIG 3 Wire Colors.JPG

The next step is to connect the wires as per the wiring table above.

FIG 4 Wire Colors.JPG

Once the back plate has been fitted and the wiring is complete, the top casing can be inserted onto the bottom casing like shown above.

FIG 5 Wire Colors.JPG

Complete the hardware installation by fixing the snake eye screws (security screws) to the top and bottom casing (#6-32X5/16″ SS).

4. Configuration

Open the Safetrust Wallet APP and select Manage Sensor tab. Make sure your system admin has set you up with this role.

FIG 7 Configuration.jpg

With the Admin Installer tab open from the App, bring the phone in range of the IoT Sensor and once visible from the App, highlight and select “Configure”.

FIG 8 Configuration.jpg

  • Choose an Identity System.
  • Specify the Type of access from the dropdown (eg. Door, Gate etc.)
  • Assign a short Name and Description using alphanumeric characters.
  • Choose an Output for the sensor (the default is set to Wiegand).

FIG 9 Configuration.jpg

When the IoT Sensor information is saved successfully to Credential Manager and assigned to the Identity System, the new description will appear in the Manage Sensor tab with a unique serial number assigned.

5. Testing

FIG 10 Testing.JPG

FIG 11 Testing.JPG

6. Regulatory Information

FCC: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Canada Radio Certification: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

CE Marking: Safetrust hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

07. Support

Thank you for purchasing the Safetrust IoT Sensor Keypad.

If for any reason you need assistance with your installation, please contact your local Sales representative . Sincerely –

The Safetrust Team

www.safetrust.com/support

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals