Notes on This Manual
1 .1 Scope of Validity
This manual describes the assembly, installation, commissioning, maintenance
and troubleshooting of the following model(s) of Fox ESS products:
A7300P1-E1-R ; A7300P1-E1-B
A7300P1-E1-S. A7300P1-E2-R
A7300P1-E2-B, A7300P1-E2-S
A7300S1-E1-R, A7300S1-E1-B
A7300S1-E1-S. A7300S1-E2-R
A7300S1-E2-B; A7300S1-E2-S
Note: Please keep this manual where it will be accessible at all times.
1.2 Target Group
This manual is for qualified electricians. The tasks described in this manual
only can be performed
by qualified electricians.
1.3 Symbols Used
The following types of safety instructions and general information appear in
this document as described below:
Symbols | Explanation |
---|---|
Danger! |
“Danger” indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
| Warning!
“Warning” indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
| Caution!
“Caution” indicates a hazardous situation which, if not avoided, could result
in minor moderate injury.
| Note!
“Note” provides important tips and guidance.
| Symbol Explanation CE mark. The charger complies with the requirements
of the
applicable CE guidelines.
| Beware of hot surface. The charger can become hot during operation. Avoid
contact during operation.
| Danger of high voltages.
Danger to life due to high voltages in the charger!
| Danger.
Risk of electric shock!
| Read the manual.
| Product should not be disposed as household waste.
Safety
Fox ESS EV chargers are designed and tested in accordance with international
safety requirements.
However, certain safety precautions must be taken when installing and
operating this. The installer must read and follow all instructions, cautions
and warnings in this installation manual.
– All operations including transport, installation, start-up and maintenance,
must be carried out by qualified, trained personnel.
– The electrical installation & maintenance of the charger shall be conducted
by a licensed electrician and shall comply with local wiring rules and
regulations.
– Before installation, check the unit to ensure it is free of any transport or
handling.Unauthorized removal of necessary protections, improper use,
incorrect installation and operation may lead to serious safety and shock
hazards or equipment damage.
– Do not install the equipment in adverse environmental conditions such as in
close proximity to flammable or explosive substances; in a corrosive or desert
environment; where there is exposure to extreme high or low temperatures; or
where humidity is high.
– Do not use the equipment when the safety devices do not work or are
disabled.
– Use personal protective equipment, including gloves and eye protection
during the installation.
– Inform the manufacturer about non-standard installation conditions.
– Do not use the equipment if any operating anomalies are found. Avoid
temporary repairs.
– All repairs should be carried out using only approved spare parts, which
must be installed in accordance with their intended use and by a licensed
contractor or authorized Fox ESS service partner.
– Liabilities arising from commercial components are delegated to their
respective manufacturers.
Packing List
Object | Name | Qty |
---|---|---|
A | Charger | 1 |
B | Mounting backplane | 1 |
C | Mounting bracket | 1 |
D | RFID card | 2 |
E | Expansion Tube | 4 |
F | Expansion Screw | 4 |
G | Tubular terminal | 3 |
H | Screw assembly | 2 |
I | Self tapping screw | 2 |
Introduction
Plug version
Socket
version
Technical Data **
**
Model | A7300 |
---|
General
Name| AC Charger
Input
Input line| 1P+N+PE
Rated voltage| 230Vac,±20%
Rated current| 32A
Rated frequency| 50/60Hz
Output
Output voltage| 230Vac,±20%
Maximum output current| 32A
Rated power| 7.3kW
Interaction method
Charging connection method| With cable/socket
Card reader| Mifare ISO/IEC 14443 A
Start-up mode| Plug and Charge/RFID Card/APP
Communication method
Bluetooth| Yes,3db,-40-85℃
WiFi| Yes,2412-2484MHz,802.11b/g/n:20db
Using environment
Installation method| Wall mounting/column mounting
Working temperature| -30°C~50°C
Working humidity| 5%-95% no condensation
Altitude| ≤2000m
Size and weight
Size| 320190144.5 mm(socket),320190130 mm(plug)
Weight| 2.0kg(socket),3.55kg(plug)
Safety
Waterproof rating| IP65
Anti-collision grade| IK08
Type A RCD| 6mA DC
Protection function| Over-current protection, grounding protection, lightning
protection, over-voltage protection, under-frequency protection, over-under-
temperature protection
Certification| CE/UKCA
Certification standard| EN/IEC 61851-1: 2019, EN/IEC 61851-21-2: 2018
Installation
6.1 Product Handling
To ensure safety, the following points should be paid attention to:
– All accessories are placed separately during transport or handling.
– Avoid violent shock and impact, and take it lightly.
– Avoid inversion.
6.2 Out of the box inspection
– Open the charging pile packaging, please check the random attachment
according to the attachment list.
– Check the charging pile for damage in transport. If damage or missing parts
are found, do not boot up and inform the carrier and dealer. Determine if this
machine is the model that you want to purchase.
– Note: Please keep the packing boxes and packaging materials for future
handling.
6.3 Install
-
Pre-installation preparation
The following tools are required for the installation:
Cross screwdriver, special plum screwdriver, stripping pliers, pressing pliers. -
Installation precautions
Please strictly follow the wiring requirements and correct access. Please confirm that all fasteners are locked to secure the charging pile. -
Installation placement environment and location
– The area where the charger must be placed must be well ventilated, far away from water, combustible gas and corrosive agent.
– Ensure that the ground or installation platform can withstand the weight of the charger.
– If the charger is disassembled and used at low temperature, there may be water droplets condensation phenomenon, be sure to wait for the charger inside and outside completely dry.
After dryness can be installed and use, otherwise there is a danger of electric shock.
– Please place the charger near the mains input to disconnect the mains input switch and cut off the power supply in an emergency.
Note: The actual installation needs to comply with local installation
requirements and local safety regulations.
Ensure that the wall or column is vertical or positive 15 ° before
installation.
• Wall-mounted installation method:
- Open the package and mark 4 holes in the wall (φ 8 * 50mm).
- Fit into the expansion tube.
- Attach the mounting back plane with screws to the mounting wall.
- Attach the bracket to the charger.
- Hang the charger into the mounting back plate and screw it.
- Installation completed.
Note: Installation wall angle 90°±15,thickness > 50mm
• Floor type /
Vertical installation method:
- Drill holes on the cement floor,four 165 * 95 holes with diameter φ 10mm deep 50mm screws and one φ 60mm through duct hole.
- Install and fix the anchor screws.
- The input line runs through the column hole through the bottom of the column.
- Install the back plane is fixed to the landing column with screws.
- Attach the bracket to the charger.
- Hang the charger into the mounting back plate and screw it well.
- Installation completed.
Note: The angle of cement ground 90°±15
Electrical
Connection
The leakage protection switch needs to be installed.The leakage protection
switch shall use TypeA, not less than 63A. And the input wire leads out from
the leakage protection switch, choose7~9 AWG wire.
Step 1 : Peel three L, N and PE copper 16mm with wire stripping pliers,
and press L, N, PE and tube terminals with terminal pliers.
Step 2: Loosen the screw nut and puncture the hole.
Step 3 : Open the side cover, load the cable (13-18mm) and tighten the
gram head.
Step 4: Unscrew the terminal screws. Link L.N.PE line lock the terminal
screw, lock the side cover.
Note :Choose 7~9 AWG three core wire.
APP download
Users can scan the QR code (Android and IOS ) in the quick installation manual, or go to the App Store and Google Play to search for Fox Switch.
Operation
8.1 Charger Status Indicators
LED Indicator description | Definition |
---|---|
Green Flashing | Device available |
Blue Steady | EV connected,User not authorized |
Blue Flashing | Authorized, Wait for charging |
Blue marquee light | Charging |
Blue Flashing | Charging suspension |
Green Steady | Charging Finish, Wait for unplug |
Yellow Steady | Charging Locking |
Red Steady | Device Fault |
8.2 Charging mode and Operation
Users can set three charging modes through the charging mode setting interface
of the APP: controlled, locked, plug and charge.
A. Plug and charge mode
Charging will start automatically after EV plugged in. If you want to stop the
charging, just press the stop button on the side of the charger.
Start Charging:
- Set the charger to the Plug and Charge mode
- Insert the charging plug into the EV
- Charging session started
Stop Charging:
Press the stop button on the side of the charger.
A. The controlled mode
Initiate or cease charging by using APP or by swiping RFID card on this mode.
You can also use APP for Reservations.
The
controlled mode with RFID card
Start Charging:
- Set the charger to the Controlled mode
- Insert the charging plug into the EV
- Swipe card
- Waiting for authorizing
- Charging session started
Stop Charging:
- Swipe card
- Charging session end
The controlled mode with APP
Start Charging:
- Set the charger to the Controlled mode
- Insert the charging plug into the EV
- Click to Start the Charge on the APP
- Waiting for authorizing
- Charging session started
Stop Charging:
- Click to Stop the Charge on the APP
- Charging session end
A. The locked mode
On this mode, the charger is locked and cannot be used.
Note: Please refer to the app user manual for the specific operation of the app.
Maintenance
Troubleshoot by Alarm information on APP or LCD display
If fault occurs, users can check the fault information on the APP or by blinks
of the LED indicator light.
No. | Fault code on app | Solution |
---|---|---|
1 | Electronic lock fault | Set the electronic lock status to the correct |
position.
Or seek help from us.
2| Emergency stop fault| Reset the emergency stop button.
Or seek help from us.
3| Abnormal CP voltage| seek help from us.
4| Abnormal AC output contactor| seek help from us.
5| Over current| Reduce output current.
Or seek help from us.
6| Over voltage| Wait for the grid voltage to return to normal.
Or seek help from us.
7| Undervoltage| Wait for the grid voltage to return to normal.
Or seek help from us.
8| Electric leakage| seek help from us.
9| Reverse connection of lin N| Correctly connect P and N lines.
Or seek help from us.
10| Abnormal frequency| Wait for the grid frequency to return to normal.
Or seek help from us.
11| Over temperature of charging interface| Wait for the temperature of
charging interface to return to normal.
Or seek help from us.
Decommissioning
10.1 Dismantling the charger
– Disconnect the charger from AC Input and AC output.
– Disconnect communication and optional connection wirings. Remove the charger
from the bracket.
– Remove the bracket if necessary.
10.2 Packaging
If possible, please pack the charger with the original packaging. If it is no
longer available, you can also use an equivalent box that meets the following
requirements.
– Suitable for loads more than 30 kg
– Contains a handle
– Can be fully closed
10.3 Storage and Transportation
Store the charger in dry place where ambient temperatures are always between
-40°C – + 70°C.Take care of the charger during the storage and transportation;
keep less than 4 cartons in one stack. When the charger or other related
components need to be disposed of, please ensure it is carried out according
to local waste handling regulations. Please be sure to deliver any charger
that needs to be disposed from sites that are appropriate for the disposal in
accordance with local regulations.
The copyright of this manual belongs to FOXESS CO., LTD. Any corporation or
individual should not plagiarize, partially or fully copy (including software,
etc.), and no
reproduction or distribution of it in any form or by any means is permitted.
All rights reserved.
FOXESS CO., LTD.
Add: No.939, Jinhai Third Road, New Airport Industry
Area, Longwan District, Wenzhou,
Zhejiang, China
Tel: 0510- 68092998
WWW.FOX-ESS.COM
V1.0
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>