Hybrid Series H60 Tube Type LED Lamp Instruction Manual

June 10, 2024
Hybrid

Hybrid Series H60 Tube Type LED Lamp Instruction Manual
Hybrid Series H60 Tube Type LED Lamp

Package Contents

  • 1x Hybrid60 OR Hybrid120 tube type LED lamp
  • 1 x SGC replaceable Li-Ion 16000mAh capacity Battery Pack
  • lx AC Power Supply
  • lx Mini Safety Chain
  • 1 x User Manual

Package contents may be updated or changed without notice. `Various accessories are constantly being developed. Please check our website www.sgclights.com to learn more.

Product Specification

Models H60 H120
Optics White Diffuser
Beam Angle 150′
Color Temp. 2700-6000K
Color Temp. Tolerance +100K
Color Accuracy Standard CRI>95. TLCI>95
Power Input Range DC 24V
Power Consumption 20W 40W
Power Port DC input. 2 5″5.5mm barrel connector
Lumens (@6000K) 23001m 4600Im
Dimming 0-100°0
Software Interface On-board Controller with Display
IP Rating IP50
Operational Temp. -20–40’C
Fixture Dimensions 043’600mm 043’1200mm
Fixture Weight 0.7kg 1.0kg
Battery Capacity 16000mAh 16000mAh
Battery Pack Charge Life Expected battery pack capacity

after 300 charging cycles: >70°0
Expected Lamp Life| 25000 Hours
Controls| Manual on-board control, wired/wireless DMX,
Wireless Remote Controller (optional)

Functional Description

Functional Description

  1. Menu Screen
  2. Power Switch
  3. “Minus/Left” Button
  4. “Confirm” Button
  5. “Plus/Right” Button
  6. DMX OUT Port
  7. “Confirm” Button
  8. DC Input Port
  9. Safety Chain Brackets
  10. Rechargeable Battery Pack
  11. Locking Pin Indicator
  12. Battery Cap

Operations: Li-Ion Rechargeable Battery Pack

Removing and Inserting of Battery Pack

  1. Twist the battery cap to unlock and remove it from end cap
  2. Use the built in tab to pull out the battery pack or insert it
  3. Align the locking-pin indicator when re-inserting the battery cap

Charging – Directly inside a fixture (default)
Directly inside

  • When a supplied AC power supply is connected to the fixture, it will provide power for the fixture to operate and/or charge the rechargeable battery pack depending if the battery is inside or not.
  • Below is the list of Battery Status Icons on the fixture’s Control Screen

Solid battery icon with bars: current Battery Level
Flashing empty battery icon: the battery has less than 5% charge remaining and needs to be charged
Empty battery icon with a lightening sign: the battery is being charged

Charging – Using an external battery charger (optional)

  • An optional external battery charger can be purchased to charge additional battery packs separately.

Operations: Menu Navigation, Structure and Parameters

Control Button Functions

  • When the fixture is powered on, the CCT menu is displayed, showing Color Temp. and Intensity parameters.
  • To change Color Temp., press / To change Intensity, press and then press I .
  • For Main Menu, press and hold H. Press / to scroll through options.
  • To set the DMX Address, press on DMX. Press / to select the Address. Press and hold 🙂 to Save.
  • To Reset to Default, press [_ on RST. Press to select Yes. Press to Reset Lamp.

Control Menu Listing

Main Menu Sub Menu Parameters Description
CCT Color Temp. 2700-6000K Adjust Color Temperatureby 100k
CCT Intensity 0-100% Adjust Brightness 1%
DMX DMX Address 001-512 Set the DMX address forthe fixtureBy default.

the first addressis assigned to Intensity,and the subsequent numberis assigned to Color Temp.
RST| | Yes/No| Factory reset that resets thelight to following parameters:100% brightness,3200K Color Temperature,DMX Address 001