IMPORTANT
THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.

Caution: Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes.

Warning: When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference.

Warning: Service to be performed by authorized service personnel only

NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an “electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water.

When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed.

This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the remainder of the building’s plumbing circuits.

Patentzurn-elkay.com/patents

WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov

Figure 1 – Rough-in Dimensions
Dimensions 

LEGEND
A = 1-1/4” Waste Tube
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER *GFCI)**

BOTTLE FILLER / FOUNTAIN RETRO-FIT CONVERSION

Typical current installation with fountains and panels removed. Disassemble current Bi-Level Refrigerated fountain installation
Figure 2

Remove left hand mounting frame, replace with new open frame (included).
Figure 3
BOTTLE FILLER / FOUNTAIN RETRO-FIT CONVERSION

REQUIRED TOOLS AND MATERIALS

These tables show special tools and/or additional materials (not provided) which are necessary to complete installation of these units:

Tools Not Provided

Description| Quantity
Safety Glasses| 1
Gloves| 1
Electric Drill / 5/32” Bit| 1
Wrenches, Crescent Wrench,| 1
Channel Lock Type Pliers| 1
5/16” Nut Driver| 1
Hammer / Center Punch| 1
Sockets & Ratchet Wrench| 1
Additional Materials Not Included

Description| Quantity
Unplated copper inlet pipe| 1
Service Stop/Shut-off Valve| 1
90° 1-1/4” Drain Line| 2
1-1/4” Tee Drain Line| 1

  1. Prepare for conversion. Turn off electrical power and water supply to existing installation.

  2. Disassemble the current installation (See Fig. 2).

    • Remove existing fountains and plumbing connection lines.
    • Remove upper and lower panels
    • Remove left hand mounting frame
  3. Install new mounting frame into left hand side of wall opening.

    • Secure mounting frame to wall opening and adjacent frame.
    • Use all fastener holes to secure the frame properly
  4.  (For HTHBWF-OVL-RF) If an existing filter is not present, install filter bracket on chiller (Fig. 4) , then install the filter head to the bracket, plumb from the filter outlet to the chiller inlet with ¼” poly tubing and ¼ x ¼ union, install filter.
    Figure 4 – HTHBWF-OVL-RF Filter Mounting (not required with HTHB-OVL-RF)
    Filter Mounting

  5. (For HTHB-OVL-RF) Verify that a strainer is installed on the water supply line to the chiller (Fig. 11).

  6. Install chiller on shelf, install ¼ x ¼ x ⅜ tee on chiller output tube. With the back panel standing close to the frame, connect ⅜” poly tube from the bottle filler to the chiller outlet tee.

  7. Install reset switch for bottle filler ( Fig. 7). Snap the switch into position after locating wires through slot. Wrap up the excess cord.

  8. Hang main panel on mounting frame hanger. Make sure the power cord, reset switch wire & poly tube do not get pinched between the panel & mounting frame. Ensure the panel engages at the top. Align fountain holes with mounting frame holes.

  9. Remove protective coating from main (upper) panel.
    Figure 5 – HTHB-OVL-RF Tube Routing
    Tube Routing
    Figure 6 – HTHBWF-OVL-RF Tube Routing
    Tube Routing

  10. Install fountains with (4) 5/16-18 HHMS, (4) 5/16-18 nuts & (from original installation) ( Fig. 7). Connect the ¼” water lines from the fountain to the remaining opening on the tee at the remote chiller (cut lines to fit as needed), (Test fit refrigerated panel to make sure there is a tight joint between it & the main panel before fully tightening mounting screws.)
    Figure 7 – Fountain Installation
    Fountain Installation

    Install fountains

  11. Attach waste tubes (1-1/4” O.D.) to 1-1/4” O.D. slip trap. Trap on the bottle filler side must be 1-1/2” O.D. (Traps and connection fittings provided by others).

  12. Drill a 5/32” (.156”) diameter mounting hole in right hand frame to secure the lower right corner of the upper panel.

    • Center the hole in tab opening.
    • Secure the panel to the frame with (screw in kit Item 8).
  13. Make final water supply connections. Turn on water supply, check for leaks. Repair leaks as required.

    • These products are designed to operate on 20-105 PSI supply line pressure. If inlet pressure is above 105 PSI, a pressure regulator must be installed in the supply line.
    • (Caution: Any damage caused by connecting these products to a supply line with pressure lower than 20 PSI or higher than 105 PSI IS NOT covered under warranty.)
  14. Make electrical connections to the bottle filler and remote chiller. The LCD Bottle counter should illuminate. Refer to BF11 Program instructions for additional details on Bottle Filler setup.

  15. Verify proper dispensing from the bottle filler by placing a cup, hand or any opaque object in front of sensor area and verify water dispenses.
    Note: the first initial dispenses might have air in the line which may cause a sputter. This will be eliminated once all air is purged from the line. A steady stream of water assures all air is removed. The sensor has a 20 second maximum ON time. It may be necessary to step away from the beam a few times to purge all air. Check for leaks.

  16. Reconfirm the installation has no leaks. Install the lower (louver) panel.
    Figure 8 – Lower Panel Installation
    Lower Panel Installation 

NOTE: The following items are not used with the converted installation:

  • One Fountain Assembly
  • Wall Frame – Left Side
  • Upper Panel
  • Lower (Louver) Panel

BF11 – BF12 PROGRAM SETTING THE CONTROL BOARD

VERIFY CONTROL BOARD SOFTWARE

  1. To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted.
  2. Shut down the unit by unplugging the power cord from the wall outlet or switching off the circuit breaker to the unit.
  3. Restart the unit by plugging the power cord back into the wall outlet or by switching on the circuit breaker to the unit.
  4. Upon start up, the bottle count display will show the software designation of BF11 or BF12.

ACCESSING THE PROGRAMMING BUTTON

  1. To access the program button, remove the bottom lower louvered panel (Fig. 7) by removing the lower panel screws. Reset button is located on the mounting bracket.

RESET THE FILTER MONITOR

  1. Instructions apply to filtered units only.

  2. Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
    “RST FLTR” – Reset Filter Monitor
    “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.

  3. When the display changes to “RST FLTR”, depress the button again. The display will change to show “FLTR =”. Depress the button again and the display will show “FLTR =0”

  4. The Green LED should be illuminated indicating that the visual filter monitor has been reset.

SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE

  1. Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
    “RST FLTR” – Reset Filter Status LED“SETTINGS” – System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.

  2. When the display changes to “SETTINGS”, depress the button again. The display will change to show
    “RNG SET” – Range set for IR sensor.
    “UNIT TYP” – Type of unit (REFRIG or NON-RFRG)
    “FLT SIZE” – Select filter capacity
    “RST BCNT” – Reset bottle count

  3. When display shows “RNG SET” push program button once the display will show current value (can be 1 – 10) e.g. “RNG = 3”.

  4. Once display shows current value push the program button to scroll through value of 1 – 10. Select the desired range setting, “1” being closest to sensor and “10” being farthest away.

  5. Once range is selected allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode.

  6. Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed.

SETTING UNIT TYPE

  1. Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
    “RST FLTR” – Reset Filter Status LED
    “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.

  2. When the display changes to “SETTINGS”, depress the button again.
    The display will change to show
    “RNG SET” – Range set for IR sensor.
    “UNIT TYP” – Type of unit (REFRIG or NON-RFRG)
    “FLT SIZE” – Select filter capacity
    “RST BCNT” – Reset bottle count Continued from below:

  3. When display shows “UNIT TYPE” push program button once the display will show current value. Can be REFRIG or NON-RFRG

  4. Push button once to change value. Once value is selected the display will show the new value. (Can be REFRIG or NON-RFRG)
    “REFRIG“ – stands for refrigerated product. In this setting the flow rate is estimated at 1.0 gallon per minute.
    “NON-RFRG“ – stands for nonrefrigerated product. In this setting the flow rate is estimated at 1.5 gallons per minute. Both “REFRIG“ and “NON-RFRG“ simulate 1 bottle equal to 20 oz.

  5. Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode.

RESETTING BOTTLE COUNT

  1. Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
    “RST FLTR” – Reset Filter Status LED
    “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.

  2. When the display changes to “SETTINGS”, depress the button again.
    The display will change to show:
    “RNG SET”- Range set for IR sensor.
    “UNIT TYP” – Type of unit (REFRIG or NON-RFRG)
    “FLT SIZE” – Select filter capacity
    “RST BCNT” – Reset bottle count
    If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode.

  3. When display shows “RST BCNT” push program button once the display will show current value, e.g. “0033183”.

  4. Once display shows current value push the program button once more to reset back to 0. The display will show BTLCT = 0 for approximately 2 seconds and then return to run mode showing 00000000 bottles.
    NOTE: Once the bottle count is reset to zero there is no way to return to the previous bottle count.

  5. Testing the bottle counter:
    REFRIG units: Place bottle or hand in front of sensor for approximately 9 seconds to see bottle counter count 00000001, (This is based on filling a 20 oz. bottle).
    NON-RFRG units: Place bottle or hand in front of sensor for approximately 6 seconds to see bottle counter count 00000001, (This is based on filling a 20 oz bottle).

SETTING FILTER CAPACITY

  1. Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
    “RST FLTR” – Reset Filter Status LED
    “SETTINGS” – System Settings Sub Menu
    If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.

  2. When the display changes to “SETTINGS”, depress the button again.
    The display will change to show:
    “RNG SET“- Range set for IR sensor.
    “UNIT TYP“ – Type of unit (REFRIG or NON-RFRG)
    “FLT SIZE” – Select filter capacity
    “RST BCNT“ – Reset bottle count
    If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode.

  3. When display shows “FLT SIZE” push program button once. The display will show current value. Can be 3000GAL or 6000GAL.

  4. Push program button again to display the desired “FLT SIZE”.

  5. Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode.
    Figure 9
    overview

PARTS LIST

ITEM NO.| PART NO.| DESCRIPTION
1| 99003C| Reset Switch Assy
2| 0000000711| Lower Panel
3| 1000005855| Power Cord
BOTTLE FILLER REPLACEMENT PART KITS

ITEM NO.| PART NO.| DESCRIPTION
4
5
6
7
8| 98543C
98544C
2000000503
98546C
98549C| Kit – Electrical Package
Kit – EE Sensor
Kit – Solenoid Valve Replacement
Kit – Aerator Replacement
Kit – Hardware & Waterway Parts

Figure 10 Filter Head Assembly used after 01/01/2021
Filter Head Assembly

WATERSENTRY® PLUS FILTER PARTS LIST (See Fig. 10)

ITEM NO| PART NO| DESCRIPTION
9
10| 55898C
51469C| Filter Assy-3000 Gal.
Assy-Filter & Brkt includes Fltr Head/
Mtg Brkt/John Guest Fittings/Screws

TROUBLESHOOTING & MAINTENANCE

Orifice Assembly: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice by poking with a small round file not over 1/8” diameter, or using a small diameter wire

**Caution:** DO NOT file or cut orifice material

Figure 11 – Water Supply Connections
Water Supply Connections 

Actuation of Quick Connect Water Fittings: Cooler is provided with lead- free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (See Fig. 12) To insert tubing, push tube straight into fitting until it reaches a positive stop (approximately 3/4”)

Operation Of Quick Connect Fitting

Figure 12 – Filter Quick Connect Fittings
Filter Quick Connect Fittings 

FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE –WWW.HALSEYTAYLOR.COM 

1333 BUTTERFIELD ROAD, DOWNERS GROVE, IL 60515 630.574.3500
www.halseytaylor.com

Halsey Taylor logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals