Halsey Taylor SCWT14WQ1K Barrier Free Water Cooler Owner’s Manual

July 1, 2024
Halsey Taylor

Halsey Taylor SCWT14WQ1K Barrier Free Water Cooler

Halsey-Taylor-SCWT14WQ1K-Barrier-Free-Water-Cooler-FIG-
\(2\)

Specifications

  • Model: SCWT14WQ*1K
  • Product Name: SCWTTM Series Barrier-Free Water Cooler
  • Refrigerant: HFC-134A
  • Recommended Circuit: Dedicated circuit with load protection sized for 20 amps and hospital-grade GFCI

Product Usage Instructions

Push Button Valve Adjustment

To adjust the stream height and eliminate valve lever free play or continuous flow from the bubbler, follow these steps:

  1. Locate the stream height adjustment screw (See Fig. 3).
  2. Adjust the screw as needed to achieve the correct stream height.

Condenser Water Valve Adjustment

To adjust the condenser water valve, follow these steps:

  1. Start up the compressor by depressing the cooler push button(See Fig. 1 – Item 4).
  2. Keep water running during the entire readjustment procedure.

FAQ

  • How do I adjust the stream height of the water cooler?
    To adjust the stream height, locate the stream height adjustment screw and turn it to achieve the desired height as per the user manual.

  • What refrigerant does the water cooler use?
    The water cooler uses HFC-134A refrigerant as specified in the user manual.

Note : Danger! Electric shock hazard. Disconnect power before servicing unit.

**USES HFC-134A REFRIGERANT

Halsey-Taylor-SCWT14WQ1K-Barrier-Free-
Water-Cooler-FIG- \(3\)Halsey-Taylor-
SCWT14WQ1K-Barrier-Free-Water-Cooler-FIG- \(4\)**

  • A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm)
    FROM WALL SHUT OFF BY OTHERS

  • B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN

  • C = 1-1/4 TRAP NOT FURNISHED

  • D = ELECTRICAL OUTLET LOCATION

  • E = INSURE PROPER VENTILATION BY MAINTAINING 4″ (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS
    TO WALL.

  • F = POWER CORD 4′ (1219mm) LONG

  • G = WALL SCREW HOLES

  • H = 2 X 4 BLOCKING

PUSH BUTTON VALVE ADJUSTMENT

Halsey-Taylor-SCWT14WQ1K-Barrier-Free-
Water-Cooler-FIG- \(5\)Halsey-Taylor-
SCWT14WQ1K-Barrier-Free-Water-Cooler-FIG- \(6\)Halsey-Taylor-SCWT14WQ1K-Barrier-Free-Water-Cooler-FIG-
\(7\)

WIRING DIAGRAM

Halsey-Taylor-SCWT14WQ1K-Barrier-Free-Water-Cooler-FIG-
\(8\)

This drawing is merely for illustrating the components of the electrical system

CONDENSER WATER VALVE ADJUSTMENT

ITEM NO. PART NO. DESCRIPTION
1 15005C Nut-Regulator Retaining
2 51544C Bubbler
3 101507531550 Push Button Stem
4 101453431640 Cap Push Button
5 102639931640 Drain Plug
6 160270508640 Strainer Plate
7 28346C Basin
8 26860C Regulator Lever
9 26861C Pivot Bracket
10 26862C Regulator Retaining Bracket
11 98773C Cold Control
*12 36312C Compressor Service Pak
13 35840C Overload
14 35768C Relay Cover
15 75589C Gasket
16 192668451550 Power Cord
**17 45696C Tailpipe Assy
18 66581C Heat Exchanger
19 75561C Elbow – 3/8″
20 50986C Regulator Holder
21 66798C Condenser Assy
22 66811C Evaporator
23 55880C Regulator Mounting Bracket
24 61314C Regulator
25 66203C Drier
26 75494C Check Valve
27 55996C Strainer
28 55913C Adaptor-Drain W/O Holes
29 75588C Nut – Slip Joint 1-1/4
30 56159C Nipple – Bubbler
31 70682C Tee – 1/4
32 See Color Table Side Panel – Right
33 See Color Table Side Panel – Left
34 35843C Relay
35 35844C Capacitor
36 56092C Poly Tubing (Cut To Length)
37 70683C Union – 1/4
NS 75583C Elbow – 5/16″ x 1/4″
NS See Color Table Front Panel

The condenser water valve is factory preset for a condenser water outlet temperature of 95° to 105° F. If actual temperature varies greatly from this, readjust water flow rate at the valve using the following procedures.

  1. START UP COMPRESSOR
    This can be accomplished by depressing the cooler push button (See Fig. 1 – Item 4). Keep water running during the entire readjustment procedure.

  2. ADJUSTMENT CONDENSER WATER VALVE
    Adjust valve by rotating adjustment stem. Rotating stem clockwise will increase water flow. Counterclockwise rotation will decrease water flow. Increasing water flow will result in a lower condenser outlet temperature, while decreasing water flow will result in a higher outlet temperature. Proper adjustment is attained when condenser outlet temperature is 95° to 105° F .Halsey-Taylor-SCWT14WQ1K-Barrier-Free-Water-Cooler-FIG-
\(9\)

Includes Items 15, 28 & 29

INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE : All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.


COLOR

| ****

RIGHT PANEL

| ****

LEFT PANEL

| ****

FRONT PANEL

---|---|---|---
Platinum (PV)| 401536248410| 401536348410| 401507448410
Stnlss Stl (SS)| 401536242830| 401536342830| 401507442830

OAK BROOK, IL 60523
630.574.3500
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals