ETC 7123K1129 Power Control Processor Mk2 Network Termination Kit Installation Guide

June 13, 2024
ETC

ETC 7123K1129 Power Control Processor Mk2 Network Termination Kit

Installation Guide

Overview

The Power Control Processor Mk2 (PCP-Mk2) is used in Echo Relay Panel Mains Feed and Elaho Relay Panel Mains Feed (ERP Mains Feed), Echo Relay Panel Feed through and Elaho Relay Panel
Feed through (ERP Feed through), and Sensor IQ systems.

WARNING: RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all power to the panel before working inside could result in serious injury or death.

De-energize main feed to the panel and follow appropriate Lockout/Tagout procedures as mandated by NFPA 70E. It is important to note that electrical equipment such as relay panels can present an arc flash hazard if improperly serviced. This is due to the high amounts of short-circuit current available on the electrical supply to this equipment. Any work must comply with OSHA Safe Working Practices.

Included in the Kit

7123K1129 ERP-FT and 7131K1029 Sensor IQPCP-Mk2 Network

Termination Kits

7123K1029 ERP PCP-Mk2 Network Termination Kit

Required Tools

  • Phillips screwdriver
  • Slip joint pliers
  • Sheathing tool or cutter for Cat5 cable jacket

Power Control Processor Mk2 Network Termination Kit

Wire the Connector
The Category 5 surface-mount connector supplied in this kit includes two pieces: a base unit and a cap. The cap has colored markings on one end to indicate where to insert each of the cable’s color-coded wires. Follow the T568B wiring scheme, as illustrated on the cap sticker, for compatibility with ETC network wiring conventions.

  1. Leave a length of about 25 cm (10 in) in the panel for connecting and for slack for future service needs.

  2. Follow standard Cat5 installation procedures to remove the end of the cable jacket and expose the conductors:
    • Remove about 13 mm (1/2 in) of the end of the outer cable jacket using a sheathing tool or cutter, making sure not to damage the insulation of the inner conductors. If one or more of the conductors are damaged during this process, cut the cable off squarely and start again.

  3. Untwist the conductors and line them up according to the T568B color-coded markings.
    Insert the conductors into the connector cap. The cable jacket should come close to the edge of the connector with as little of the conductors visible as possible. Otherwise, cut off the cable squarely and start again.

  4. If any conductors extend beyond the edge of the connector cap, trim the excess so that the ends of the conductors are flush with the edge of the connector cap.

  5. Press the cap firmly on the connector base until the two pieces snap together. Use slip joint pliers to apply pressure evenly across the cap and to secure the connection, but make sure not to break the plastic while applying pressure.

Attach the Connector to the Box and Assemble

  1. Insert the front edge of the connector into the mounting box so that the slot in the front edge of the connector aligns with the tab in the bottom section of the box.
  2. Push down on the back of the connector to snap it into the box.
  3. The rear of the cover has a small U-shaped cutout. Remove this cutout to allow the cable to pass through without getting pinched. Route the cable through the box’s guide as shown.
  4. Align the cover with the bottom section and snap the two pieces together.

Install the Connector in the Panel

Use the double-sided tape provided in the network termination kit to attach the bottom of the surface-mount box to your panel. See the following illustrations.

Connect the Patch Cable

ERP Feedthrough or Sensor IQ
Connect the 1 ft patch cable (N4036) from the surface-mount connector to the back of the user interface.

Note: The Sensor IQ shown above is mounted in a top-feed orientation.

ERP Mains Feed

Bottom Feed

  1. Route the 4 ft network patch cable (N4009) from the surface-mount box, behind the relay card mounting panel, and through the ribbon cable opening in the bottom of the user interface enclosure.
    • The kit includes a cable tie and adhesive cable tie mount to dress the patch cable, as needed.

  2. Connect the patch cable to the back of the user interface.

  3. Connect the patch cable to the surface-mount box.

Corporate Headquarters n Middleton, WI, USA | +1 608 831 4116
Global Offices n London, UK | Rome, IT | Holzkirchen, DE | Paris, FR | Hong Kong | Dubai, UAE | Singapore
New York, NY | Orlando, FL | Los Angeles, CA | Austin, TX
Web etcconnect.com | Support support.etcconnect.com | Contact etcconnect.com/contactETC
© 2023 Electronic Theatre Controls, Inc. | Trademark and patent info: etcconnect.com/ip
Product information and specifications subject to change. ETC intends this document to be provided in its entirety.
7123M2310 Rev B Released 2023-04