Spa Electrics LiT Yard 2 Controller Owner’s Manual

June 12, 2024
Spa Electrics

Spa Electrics - logo LiT YARD
OUTDOOR LIGHTING SYSTEM
INSTALLATION & OWNER’S MANUAL

BEFORE YOU START

LIGHT REQUIREMENTS
ENSURE ALL YOUR LIGHTS ARE LiT YARD COMPATIBLE BEFORE INSTALLATION THE LiT YARD SYSTEM IS NOT COMPATIBLE WITH MULTI COLOUR PRODUCTS

READ THIS FIRST

Read and follow the safety instructions listed below and other basic safety precautions before installation or operation of this transformer and other associated equipment.
This power unit is specifically designed to supply 12 VAC to landscape, fountain, swimming pool and spa luminaires.
Installation must comply with provisions of the National Electrical Code, ANSI/NFPA 70, including those in Article 680 – Swimming Pools, Spas, Fountains and Water Features.
CAUTION: for use only on a branch circuit protected by a class a type ground fault circuit interrupter.
Power supplies are for outdoor use only. Not for use with an extension cord.

WARNING
If the installation requires running wire through building structure, special wiring methods are needed.
Do not submerge.
Do Not exceed the maximum ratings of individual components, wiring devices and current carrying capacity of conductors.

PRODUCT SUPPORT & INFORMATION

VISIT: WWW.SPAELECTRICS.COM

WHAT’’S INCLUDED

Spa Electrics LiT Yard 2 Controller - package

MOUNTING THE CONLLER

POSITIONING
ENSURE THE LiT YARD 2 OUTDOOR LIGHTING CONTROLLER IS WALL MOUNTED AT LEAST 20″ (500mm) ABOVE GROUND AND IN A SERVICEABLE LOCATION

Spa Electrics LiT Yard 2 Controller - controler

SCREW KIT INCLUDED FOR LiT YARD 2

NOTE
This product has been designed for use with PVC/Flexible conduit, it is not intended to be used with metallic conduit. Connections/hubs need to be UL Listed, weather/rain-tight and suitable for the application. All conduits should be
adequately supported to prevent excessive stress on the enclosure

MOUNTING THE RF BRIDGE

POSITIONING
WHEN FINDING A LOCATION TO MOUNT THE LiT YARD 2 RF BRIDGE, THERE ARE SOME FACTORS THAT WILL IMPROVE THE CONNECTIVITY OF YOUR RF BRIDGE TO YOUR REMOTE HANDSET.
THE RF BRIDGE SHOULD BE MOUNTED:
– IN AN ELEVATED POSITION.
– OUTSIDE OF ENCLOSURES eg. PUMP HOUSES OR GARDEN SHEDS

Spa Electrics LiT Yard 2 Controller - mounting

MINIMIZING THE NUMBER OF OBSTRUCTIONS BETWEEN THE RF BRIDGE AND THE REMOTE HANDSET WILL IMPROVE THE CONNECTIVITY BETWEEN THE DEVICES. MATERIALS SUCH AS TIN, STEEL AND  CONCRETE CAN HAVE A DETRIMENTAL AFFECT ON THE RF BRIDGE SIGNAL TO THE REMOTE HANDSET.
THE REMOTE HANDSET SHOULD BE WITHIN A 54 yard (50m) LINE OF SIGHT OF THE RF BRIDGE.

INSTALLING THE KEYHOLE SCREW
THE RF BRIDGE USES A KEYHOLE HOOK ARRANGEMENT FOR MOUNTING FASTEN THE SCREW INTO THE WALL MATERIAL UNTIL THE SCREW HAS 1/4-1/2 inches (7-11MM)] STILL EXPOSED FROM THE WALL

ATTACHING RF BRIDGE TO KEY HOLE SCREW

  1. SLIDE THE RF BRIDGE OVER THE MOUNTING SCREW USING THE KEYHOLE ON THE REAR OF THE UNIT.

  2. LOWER THE RF BRIDGE OVER THE MOUNTING SCREW TO ENGAGE THE LOCKING PORTION OF THE KEYHOLE

INSTALLING THE LOWER MOUNTING SCREW

  1. REMOVE THE LOWER COVER ON THE RF BRIDGE TO EXPOSE THE LOWER MOUNTING HOLE.
    Spa Electrics LiT Yard 2 Controller - mounting 5

  2. FASTEN A SCREW THROUGH THE LOWER MOUNTING HOLE INTO THE WALL MATERIAL.

NOTE
WHEN MOUNTING THE RF BRIDGE TO CONCRETE OR BRICK, IT IS ADVISED TO FIRST USE THE RF BRIDGE TO MARK THE MOUNTING HOLE POSITION AND REMOVE THE RF BRIDGE BEFORE DRILLING THE PILOT HOLE.

CABLE CONNECTIONS

CONNECTING THE RF BRIDGE

  1. REMOVE THE COVER AND INSERT THE RJ12 CABLE INTO THE RF BRIDGE
    Spa Electrics LiT Yard 2 Controller - connecting

  2. INSERT THE RJ12 CABLE INTO THE CABLE GUIDE SLOT ON THE LOWER COVER OF THE RF BRIDGE
    Spa Electrics LiT Yard 2 Controller - connecting 2

  3. RE-INSTALL THE LOWER COVER ON TO THE RF BRIDGE.
    Spa Electrics LiT Yard 2 Controller - connecting 3

WIRING

EXAMPLE 1
INDEPENDENT WIRING (MAX 4 LIGHTS) Spa Electrics LiT Yard 2 Controller -
wiring

NOTE
POOL & SPA CHANNELS CAN BE CONTROLLED INDEPENDENTLY OR AS A GROUP VIA THE REMOTE.

WIRING – EXAMPLE 2
BRANCH WIRING (MAX 6 LIGHTS)Spa Electrics LiT Yard 2 Controller - wiring
2

NOTE
POOL & SPA CHANNELS CAN BE CONTROLLED INDEPENDENTLY OR AS A GROUP VIA THE REMOTE.
EXAMPLE 3
MULTIPLE LIT YARD CONTROLLERS
Spa Electrics LiT Yard 2 Controller - wiring
3

LARGER INSTALLATION?
THE LiT YARD SYSTEM CAN SUPPORT A MAXIMUM OF 10 CONTROLLERS. EACH LiT YARD 2 CONTROLLER REQUIRES ITS OWN RF BRIDGE

QUICK SETUP PROCESS

BEFORE YOU START

  • The Remote Handset is designed to be used with the Spa Electrics LiT YARD 2 Controller. [Please check product labeling to ensure it is suitable)
  • For Retro-fit installations, where existing transformers have been hardwired; a suitably qualified electrician must disconnect the transformers and terminate with a plug top connection in accordance with NEC and State Electrical  Codes for hardwired installations.

LIT YARD 2 QUICK SETUP

The Remote Handset has a QUICK SETUP feature to program LiT YARD 2 for operation
STEP 1
Ensure the lights have been OFF for a minimum of 30 seconds, then turn the system ON using the Remote Handset
STEP 2
Press the following static colors in order with a 1 second pause between each press 2a. WHITE  2b. RED 2c. GREEN
If performed correctly, the lights will illuminate GREEN Confirm correct operation by selecting a different color using the Remote Handset ) Spa
Electrics LiT Yard 2 Controller - Setup

LiT YARD RF BRIDGE LED STATUS
THE FRONT OF THE LIT YARD RF BRIDGE HAS AN LED INDICATOR PLEASE SEE BELOW FOR THE STATUS OF DIFFERENT COLORS INDICATED.

Spa Electrics LiT Yard 2 Controller - stutus

HANDSET PAIRING

Your Remote Handset should come pre-assigned to the LiT YARD RF Bridge However if it is not paired, please follow the below instructions
STEP 1: Press the pairing button on the base of the LiT YARD RF Bridge. The LiT YARD RF Bridge will now switch to learning mode, indicated by the solid red LED
STEP 2: Within 7 second, press any of the buttons on the Remote Handset. The Remote Handset is now assigned to the LiT YARD RF Bridge MEMORY RESET: To reset the receiver memory, press and hold the button on the bottom of  the LiT YARD RF Bridge for 10 seconds. The LED indicator will flash fast initially, then flash slow indicating the memory has been erased. Once erased, release the Button and complete steps 1 & 2 to program the Remote Handset

TO ACCESS THE PAIRING BUTTON ON THE LIT YARD RF BRIDGE

  1. Slide down the Bottom cover of the LiT YARD RF Bridge
    Spa Electrics LiT Yard 2 Controller - wiring 4

REMOTE HANDSET OPERATION

Spa Electrics LiT Yard 2 Controller - remote

TROUBLE SHOOTING – REMOTE HANDSET

CONDITION CORRECTIVE ACTION
Flashing power indicator on Remote Handset Low Battery – Replace 2 x AAA

Batteries in Remote Handset
Intermittent communication between Remote Handset and | the RF Bridge| – Reset RF Bridge memory (see “Handset Pairing’)
– Pair Remote Handset to RF Bridge (see “Handset Pairing’] G85

FCC COMPLIANCE STATMENT

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following two (2) conditions:

  • This device may not cause harmful interference, and
  • This device must accept any interference received, including interference that may cause undesired

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different to that to which the receiver is connected.
  • Consult the dealer or an experienced radio / TV technician for help.

The device radiates radio frequency energy at a level below the United States FCC radio frequency exposure limits. Nevertheless, this device should be used in such a manner that the potential for human contact during normal operation is minimized. For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used with accessory that contains no metal. Use of other accessories may not ensure compliance with FCC RF exposure guidelines.

ISED COMPLIANCE STATEMENT
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interfer-ence, including interference that may cause undesired operation of the device.

SPECIFICATIONS

Enclosure Size: H27cm x W15c¢m x D10cm
Enclosure Type: UL Listed Polycarbonate (black)
Primary Conduit Entry: (2) V2″-%” ports, (2] %” ports
Secondary Conduit Entry: (2) 12″-%” ports, (2) %” ports
Overload Protection: Replaceable 10A blade fuse

Model Input 60 Hz. Secondary Output
Lamp Watts (W)* Voltage (VAC)
LIT YARD 4X 110VAC 100 Max.
LIT YARD 4XP 110VAC 100 Max.
  • Any combination of bulbs, any output.

TECHNICAL SPECIFICATION

RECEIVER RATING REMOTE
Input: 110VAC ~ 60Hz Battery: 2 x ‘AAA’
Output: 110VAC ~ 60Hz switched  Range: Up to 54yd (50m] – line of sight
Max. Load: 100W MAX. TOTAL Freq: 915MHz ISM Band

NOTE
PLEASE STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE

Spa Electrics LiT Yard 2 Controller - icon 1 Spa Electrics®
(C) COPYRIGHT 2021 SPA ELECTRICS
ALL RIGHTS RESERVED
20220510

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Spa Electrics User Manuals

Related Manuals