Introduction

The Leviton GFWT1-W Weather Tamper-Resistant Receptacle is a reliable electrical outlet designed for outdoor use. With a focus on safety and durability, this receptacle is built to withstand various weather conditions while providing tamper-resistant features for enhanced protection.

Specifications

Part Number ‎G19152L-WH
Item Weight ‎6.4 ounces
Package Dimensions ‎5.83 x 3.23 x 1.73 inches
Size ‎15 Amp Outlet
Color ‎White
Voltage ‎125 Volts

What’s in the Box

  • Leviton GFWT1-W Weather Tamper-Resistant Receptacle
  • Mounting screws
  • Installation instructions

Description

AIDA-Electrical-Outlet-Tamper-Resistant-Receptacle-
fig-2

Key Features

  • Weather-Resistant Design: Built to withstand various weather conditions, making it suitable for outdoor installations.
  • Tamper-Resistant Outlets: Provides added safety by preventing the insertion of foreign objects into the receptacle.
  • Durable Construction: Constructed with robust materials to ensure longevity in outdoor environments.
  • Easy Installation: Simple installation process with included instructions and mounting hardware.

Dimension

AIDA-Electrical-Outlet-Tamper-Resistant-Receptacle-
fig-4

How to Use

  1. Installation: Follow the provided installation instructions, ensuring proper wiring and mounting.
  2. Power Outlets: Use the standard power outlets for connecting outdoor electrical devices.
  3. Tamper-Resistant Feature: Benefit from the tamper-resistant design, especially in areas accessible to children.

AIDA-Electrical-Outlet-Tamper-Resistant-Receptacle-
fig-3

Safety Precautions

  1. Weather Resistance:
    • The Leviton GFWT1-W is likely designed for outdoor use. Ensure that it is rated for the specific weather conditions in your area, and it should be resistant to water, dust, and other environmental elements.
  2. Tamper-Resistant Design:
    • Tamper-resistant receptacles are designed to prevent the insertion of foreign objects, providing an additional layer of safety, especially in homes with children. Confirm that the GFWT1-W has this feature.
  3. Installation:
    • Follow the manufacturer’s installation instructions precisely. If you’re not experienced with electrical work, consider hiring a qualified electrician to install the receptacle.
  4. Weatherproof Covers:
    • If the receptacle is installed in an outdoor location, it might require a weatherproof cover to provide additional protection against the elements. Ensure that you use the appropriate cover for the installation.
  5. Ground Fault Circuit Interrupter:
    • In outdoor locations, especially those prone to wet conditions, it’s often advisable to use a GFCI receptacle. Verify whether the GFWT1-W has built-in GFCI functionality or if it should be installed in conjunction with a GFCI breaker.
  6. Regular Inspection:
    • Periodically inspect the receptacle for signs of wear, damage, or corrosion. Replace the receptacle if any issues are identified.
  7. Load Capacity:
    • Be aware of the receptacle’s load capacity. Avoid overloading it with devices that exceed its specified capacity.
  8. Compatibility:
    • Ensure that the GFWT1-W is compatible with the electrical system in your home and adheres to local safety standards.
  9. Tamper Resistance:
    • Educate household members about the importance of tamper-resistant features and discourage any attempts to tamper with the receptacle.

AIDA-Electrical-Outlet-Tamper-Resistant-Receptacle-
fig-1

Maintenance

  1. Cleanliness:
    • Keep the receptacle clean from dust, dirt, and debris. Use a dry cloth to wipe down the surface regularly. Avoid using abrasive cleaners or solvents.
  2. Weather Resistance:
    • If the receptacle is designed for outdoor use, make sure that it remains weather-resistant. Check for any signs of water ingress or damage due to exposure to the elements.
  3. Tamper-Resistance:
    • Ensure that the tamper-resistant features are functioning correctly. Tamper-resistant receptacles have built-in shutters to prevent the insertion of foreign objects. Regularly check to confirm that these shutters are operational.
  4. Weather Seals:
    • If applicable, inspect weather seals or gaskets around the receptacle cover. Ensure that these seals are intact to maintain their weather-resistant properties.
  5. Tighten Connections:
    • Periodically check the terminal connections to ensure they are tight. Loose connections can lead to overheating and reduced electrical conductivity.
  6. GFCI Testing:
    • If the receptacle includes Ground Fault Circuit Interrupter (GFCI) functionality, test it according to the manufacturer’s recommendations. GFCIs are designed to trip when they detect a ground fault, and regular testing ensures their proper function.
  7. Avoid Overloading:
    • Be mindful of the electrical load on the receptacle. Avoid overloading it with devices that exceed its specified capacity.
  8. Replacement of Damaged Parts:
    • If any part of the receptacle, such as the weather cover or faceplate, is damaged, replace it promptly. Do not attempt to repair damaged components.

Troubleshooting

  1. No Power/Functionality Issues:
    • Check the circuit breaker or fuse box to ensure the circuit is not tripped or the fuse is not blown.
    • Test other devices on the same circuit to verify if the issue is with the receptacle or the entire circuit.
  2. Resetting the Receptacle:
    • If the receptacle has a reset button, press it to reset the device. Follow the manufacturer’s instructions for proper resetting.
  3. GFCI Functionality:
    • If the receptacle is a GFCI (Ground Fault Circuit Interrupter) type, test it using the built-in test button. Press the test button and then reset it to ensure proper functionality.
  4. Visual Inspection:
    • Inspect the receptacle for any visible signs of damage, discoloration, or loose connections. If any issues are found, turn off the power to the circuit before addressing them.
  5. Weather Resistance:
    • If the receptacle is exposed to outdoor elements, ensure that it is designed for such use and that its weather-resistant features are intact.
  6. Wiring Issues:
    • If you suspect wiring issues, turn off the power to the receptacle and inspect the wiring connections. Make sure all wires are securely attached and there are no loose connections.
  7. Professional Inspection:
    • If troubleshooting does not resolve the issue, or if you are unsure about electrical work, consult with a qualified electrician for a professional inspection.
  8. Compatibility:
    • Ensure that the devices you are trying to plug into the receptacle are compatible with its specifications. Some devices may require a specific voltage or amperage.
  9. Testing with a Multimeter:
    • Use a multimeter to check the voltage at the receptacle. Be cautious and turn off the power before conducting any measurements

FAQs

What is the AIDA Electrical Outlet Tamper-Resistant Receptacle?

The AIDA Electrical Outlet Tamper-Resistant Receptacle is a safety-enhanced electrical outlet designed to reduce the risk of electrical shock and tampering.

How does the tamper-resistant feature work?

The tamper-resistant design includes internal shutters that prevent the insertion of foreign objects, providing added safety, especially in homes with children.

Is the AIDA Electrical Outlet compatible with standard electrical devices?

Yes, the AIDA Electrical Outlet is designed to be compatible with standard electrical devices such as plugs for lamps, chargers, and small appliances.

Does the AIDA Electrical Outlet meet safety standards?

Yes, the AIDA Electrical Outlet is typically designed and tested to meet relevant safety standards to ensure electrical safety and reliability.

Can the AIDA Electrical Outlet be installed in outdoor locations?

The AIDA Electrical Outlet is generally designed for indoor use. For outdoor installations, users should check the product specifications or consider weather-resistant models.

What is the voltage and current rating of the AIDA Electrical Outlet?

The voltage and current ratings may vary, so users should refer to the product documentation or labels for specific details regarding the AIDA Electrical Outlet's capacity.

Is professional installation recommended for the AIDA Electrical Outlet?

While the AIDA Electrical Outlet can often be installed by homeowners, professional installation may be recommended for those who are unfamiliar with electrical work for safety and compliance.

Does the AIDA Electrical Outlet come with a warranty?

The AIDA Electrical Outlet may come with a warranty. Users are advised to check the product documentation or contact the manufacturer for warranty details.

Can the AIDA Electrical Outlet be used in commercial applications?

The AIDA Electrical Outlet is typically designed for residential use. For commercial applications, users should explore outlets specifically rated for such environments.