The wireless siren PNI Safe House HS007 is using advanced digital security technology with good reliability and a low false alarm rate. Although the design is simple, it’s function is crucial: alerts in case of fire, gas leak, anti-burglary, sudden emergency. The product can be used with the alarm system PNI Safe House HS550, PNI Safe House HS650, PNI Safe House HS600 or it can be paired with optional multiple wireless detectors. English
FEATURES
20 wireless defense zones| One-key-control function: Remote arm, remote home
arm , remote emergency alarm, remote control disarm
---|---
Maximum 5 wireless remote controller codes| Tamper function
Sound and strobe alarm| Built-in AAA NI-MH rechargeable battery for power loss
situations
Wireless learning code for adding new accessories
SPECIFICATIONS
Power supply: DC 12V 1000mA stand-by Stand-by | Transition power: 10 maw |
---|---|
Stand-by current: ≤ 7mA | Emission distance: ≤100m (open space) |
Alarm current: ≤ 230mA | Working temperature: -26°C ~ +80°C |
Wireless frequency: 433 MHz | Relative humidity: 40%~80% RH |
DESCRIPTION AND INSTALLATION
a. Initialization
Firstly, insert the power adapter connector into the stand-alone power supply
socket, turn on the power switch (red). The built-in buzzer will ring twice,
the indicator light will flash twice.
b. Wireless or wired working mode
When the jumper is inserted in the “NO” position, this product is used as a
wired siren.
When the jumper is inserted in the “NC” position, this product is used as a
wireless siren.
Notes: only when the siren is in the wireless mode you can code remote
controllers, learn detectors and pair to an alarm system in wireless mode.
With wired mode selected, remote controller and detector do not work anymore,
and the siren would make sounds once connected to the power.
c. Stand-alone working mode
The siren can work independently as an alarm system, with remote controller
and detectors paired to it. In this mode, the remote control and the detectors
have to be coded with a standalone siren to trigger the siren to make alarms.
d. Coding of remote controllers & wireless detectors
In arm or disarm state, keep pressing the alarm set key, until it rings once
with indicator light flashing once, release the set key, then the alarm lights
flash quickly, waiting for the wireless signal from remote controller or
detector press SOS key of the remote controller or trigger detector (which
needs coding) to launch a wireless signal it means the coding process is
successful when you hear the siren releases two alert tones confirming it has
received the signal. If you want to learn the next remote controller or
detector, only trigger the remote or the detector again. If the alarm does
receive any signal within 10 seconds, it will exit the pairing mode
automatically.
Operation method: keep pressing [set] key of standalone siren, until it
sounds once with indicator light flashing once.
PAIRING SIREN WIRELESS TO A COMPATIBLE ALARM SYSTEM LIKE PNI SAFEHOUSE
HS550, PNI SAFEHOUSE HS650, PNI SAFEHOUSE HS600
At this time the siren is changing working mode to wireless external siren. It
will release an acoustic and optic alarm as long as the host has an alert.
In arm or disarm state, keep pressing the set key of standalone alarm, until
it rings 2 sounds with indicator lights twice, release the set key. Siren
lights flash quickly at this time, waiting for the host’s (alarm system)
wireless encoded signal let alarm host launch the first wireless coded signal
The siren will send out 2 long and 1 short tones, once it receives the
signal, that means successful pairing.
Operation method : keep pressing [set] key, until it makes out two sounds
with indicator light flashing twice.
a. Delete all remote controllers & accessories
You can delete all accessories from siren, if it is necessary. You cannot
operate standalone siren alarm after remote controlled is deleted. If you
delete accessories, you cannot trigger the alarm to make alarms.
In arm or disarm state, pressing its [set] key until it rings 3 times, with
indicator light flashing 3 times. Release the set key. It means deleting is
successful if you hear 2 alert.
Operation Methods: keep pressing [set] key, until it rings 3 times with
indicator light flashing 3 times.
b. Standalone alarm state
Arm state: When the siren in this state, all the accessories can trigger it to
alarm
Disarm state: When the host in this state, only the parts of the emergency
zone could trigger an alarm, and all other accessories can not trigger an
alarm
Alarm state: When the host in this state, the siren starts with alarm on spot.
In the case of no manual operation, the host will exit alarm automatically
after 3 minutes, and return to standby
c. Daily operation
Remote control is one kind of device which can carry out multi-function
operation paired with this siren. Its function is convenient for user to
control its state when he is at the door (outdoor) or long-distance, such as
out arm, home arm, emergency alarm , the instant disarm functions etc.
Out arm: press [ Arm ] key, it will be in arm alert state at once.
Disarm: press [ Disarm ] key, it will be in disarm standby state at once.
Home arm: press [ Home Arm ] key, it will be in the home arm alert state at
once.
Emergency alarm: press [ Emergency ] key, it will be an emergency trigger,
send to siren, and an instant alarm.
MAINTENANCE
a. System testing
Although the siren alarm system is used every day, it still needs regular
care, maintenance and inspection, to ensure that the alarm system will be
stable, reliable and safe. Normally the standalone siren alarm needs a
thorough inspection every 3 months and the detectors need to be checked once a
month.
B. Siren alarm host detection
Whether the alarm host can be armed and disarmed normally or not.
Whether the host can receive signal normally or not, as well as the back-up
battery is OK or not.
C. Detector detection
Manually trigger the detector to check whether it alarms normally or not.
Check batteries of all detectors to check whether they are under-voltage or
not.
Check whether wireless detector is communicated with the standalone alarm
during emission testing.
Notes: Do not dismantle, repair and modify products privately, or may
cause accidents and failures.
Do not drop the product on the ground or hard objects to avoid strong impact
to cause failure and damage.
EU Simplified Declaration of Conformity
SC ONLINESHOP SRL declares that Wireless outdoor siren
PNI Safe House HS007 complies with the Directive
RED 2014/53/UE and ROHS 2011/65/EU.
The full text of the EU declaration of conformity is
available at the following Internet address:
https://www.mypni.eu/products/6385/download/certifications