BG SYNCEV EVS7GGR-02 EV Charger Socketed 7.4kw Wall Charger User Guide
- June 11, 2024
- BG SYNCEV
Table of Contents
EV Charger
Type 2 socket, 7.4kW
EVS7GGR – COMMERCIAL / RFID
Installation and User Guide
EVS7GGR-02 EV Charger Socketed 7.4kw Wall Charger
Tools needed:
Hex bit holder, PZ2 and flat blade screwdriver, suitable drill bit and fixings
BOX CONTENT
- EV charger
- Decorative trim
- Installation template
- Accessories pack containing:
» Power connector
» Cord grip and screws
» M25 gland
» 2x 25mm blanking plug| » Fixing screw caps
» Assembly screws
» Anti-tamper bit
---|---
INTRODUCTION
This guide is intended for use by competent electrical installers to explain basic requirements and options to be considered when installed a BG SyncEV Charger. The unit is designed for installations inside or outside, the advanced safety technology we have built into the unit ensures its safe usage. This guide provides information to assist when installing the EVS7GGR charger and should not be used with other EV chargers.
SAFETY INFORMATION
Warning: The supplied BG SyncEV charger is manufactured to be safe
without risk provide they are installed correctly, used, and maintained in
accordance with the manufacturers recommendations and installed by a competent
electrical installer in accordance with national and local regulations, and
legislation applicable at the time of installation, e.g. BS7671 :2018
amendment 2.
The single phase EV charger should be connected to a 230V/240V nominal AC
supply. The supply should run from a dedicated 40A circuit breaker. We
recommend the use of a Type B curve circuit breakers. The EV charger features
an integral 30mA type-A RCD with 6mA DC leakage detection and therefore an
external RCD is not usually required:
- For cables without earthed metallic covering installed in walls or partitions at a depth of less than 50mm and also within walls and partitions with metal parts, and not protected by steel conduit or similar then RCD protection is required. This can be achieved by using the BG IP65 EV protection enclosure (CFEV1A) when mounted next to the existing consumer unit as it includes a double pole 40A 30mA Type A RCD device to protect the circuit. This can be used if the cable has no mechanical protection where it passes through walls and partitions and if the cable is buried within the ground before reaching the EV charger. This will be in compliance with the current BS7671 Amendment 2 Wiring Regulations.
- If the cable is clipped directly to the surface of a wall and does not pass through a wall or partition to the EV charger then a standard B type 40A MCB may be installed into the Consumer unit, however RCD protection may be required for other reasons such as if it forms part of a TT system and the earth fault loop impedance values cannot be met. This will be in compliance with the current BS7671 Amendment 2 Wiring Regulations.
To conform with BS 7671, on occasions a double pole MCB/RCD or other means of isolation may be required.
Important note: A DC Leakage fault in the vehicle may “blind” a type “AC” RCD and render it ineffective, never feed any EVSE From an upstream Type “AC” RCD.
EARTHING REQUIREMENTS
The supplied EV charger features an on-board safety monitoring system to
detect low or high voltage supplies and potential earth-neutral faults, this
in accordance with regulation 722.411.4.1 (iv) of BS7671 2018 (Compliant on
single phase supplies only). If such a condition is encountered the charge
cycle is ended or prevented and the EV charger indicator goes red and
effectively becomes a double insulated (class II) device. The vehicle becomes
isolated from incoming supply and poses no risk to touch. This feature removes
the requirement for an earth electrode where it may be ineffective or
introduce further risk.
The EV charger may be connected directly to a TN-C-S (PME) earthing system
without any special arrangements. It remains the responsibility of the
installer to conduct a risk assessment of the immediate area to a range of 10
meters (equipotential zone) to ensure no other conductive metal fixings pose
risks (mixture of TT/TN-S and TN-C-S), this is important where cable length
may enable charging inside or outside of a building/garage where the vehicle
is within touch distance. Where certain conditions dictate an earth electrode
must be used it shall be independent from the distributors earth system with
no direct interconnection (the incoming supply SWA protective earth should be
isolated from the housing and/ or earth electrode). The electrical installer
shall install a suitable electrode complete with termination housing and
covers where appropriate, warning labels should be visible and close to the
unconnected SWA protective earth, e.g. inside the charger.
The earth connection shall be made from the electrode to the charger via
copper conductor earth wire of an appropriate CSA for the installation. The
earth wire shall be installed in conduit where there is a risk of mechanical
damage or UV exposure. Additional note: BG SyncEV recommend Earth electrode
impedance to be <100 ohms.
SURGE PROTECTION
Guidance on requirements for surge protection devices given In BS7671: section
443.
The EV charger is protected against transient over voltages (+/-2kV Line-Earth
and +/-1 kV Line-Line as a requirement of EN 61000-6-1 ), a direct lightning
strike carries a current of 30~ 200kA the EV charger’s internal protection
would provide little or no protection in such an event, likewise nor would an
SPD rated less than 30kA. If life support equipment or business operations
could be affected by a lightning strike central SPD protection is advised if
it does not already exist.
The guidance on risk calculation in section 443.5 of BS7671 in most cases is
not possible due to unknown location of any SPD already fitted, length of
cables to calculate LP etc, it is therefore recommended a common sense
approach is used on choice of SPD (or if required).
ISOLATION AND SWITCHING FOR SAFETY AND MAINTENANCE
To ensure the EV charger can be “turned off” to enhance security and enable
maintenance activities, a double pole isolator (or DP RCD or RCBO) suitably
rated must be installed within the customer’s property.
An isolator switch is a mandatory requirement for “new builds”, but optional
for existing dwellings (at customer’s request), the switch should be mounted
between 500mm and 1500mm above finished floor level to comply with
regulations. The switch should be rated at 45 Amps.
All installations must comply to BS7671: 2018.
INSTALLATION
The EV charger is suitable for installation inside and outside on a solid wall
or structure. The installer should consult with the building owner to
establish their preferred installation location. This should take into
consideration the length of charging cable and risk of vehicle impact etc.
It is recommended the charger is installed at a height of 500mm1500mm as per
building regulations BS8300:2018.
If no suitable permanent structure is available, the EV charger can be mounted
to a stand. We suggest of the BG SyncEV Stand, EVASTAND12S.
Ensure suitable fixings are used depending on the mounting surface.
To avoid unnecessary dust inside the enclosure, it is recommended to use the
included fixing hole template drill the surface, before fitting the enclosure.
Ensure installation wall has been checked for electric cabling or pipework
with a suitable detector.
NOTE: if any groundworks are required e.g. cable trenching or earth
electrode fitment, it is advisable to check if underground services could be
present before commencement. Plans may be available at:
www.linesearchbeforeudig.co.uk (free
to domestic users).
The EV charger is suitable for bottom or rear cable entry, if using rear cable
entry ensure the blanking plug supplied is fitted to the open bottom cable
entry hole. If using SWA cable the included 25mm compression gland is NOT
suitable, and an alternative gland will be required. Do not drill alternative
cable entries into the charger housing,
except marked cable entry location for rear entry.
BG SyncEV recommends using EV-Ultra™ – Power & Data Combined cable on installs
that require a CT clamp to use the chargers dynamic load management
capabilities. Please see: www.doncastercables.com/uploads/EV-
Ultra_Datasheet.pdf
All of the cables that are to be connected into the supply connector should
have their insulation striped back 18-20mm. Connectors supplied are suitable
for cables of 4-6mm2 and suitable for solid and stranded cores.
LOAD BALANCING
If Load Balancing is required, we suggest of the BG SyncEV CT clamp, EVA
120CT1. This should be fitted around the incoming power to the main fuse and
the correct max load (A) to be entered during setup and installation steps.
FINAL ELECTRICAL TESTING
To meet the BS7671 :2018 (18th edition) requirements for testing of an
electrical installation, the following tests and checks shall be performed by
a competent electrical installer before during and after a BG SyncEV charger
is installed:
-
A visual inspection of the installation including the existing electrical installation.
-
Verification of the characteristics of the electrical supply at the origin of the installation to confirm the supply is suitable for the additional load.
-
A test to confirm the continuity of the circuit protective conductors.
-
A test to confirm the integrity of the circuit insulation resistance.
-
A test to confirm the polarity of the installation is correct. Where applicable a test to confirm the earth electrode resistance is within acceptable tolerances.
(or) -
An earth loop impedance test.
-
A test of the mechanical operation of residual current devices (RCD’s).
-
A test to confirm the operation of residual current devices (RCD’s) is within stipulated time scales (at the rated current and at five times the rated current operating current).
-
A test or calculated measurement of the prospective fault current.
-
A verification of the functional operation of the EV charger.
An electrical installation certificate must be completed.
Ensure electrical testing is done before EV charger commissioning and network
setup is performed.
For this testing, the Charger can be set to “Plug and Charge” Mode in the
installation App.
TROUBLESHOOTING
For further information, or to refer to our FAQs, please visit our website –
www.syncev.co.uk
The status of the EV charger can be identified by referencing the colour shown
on the LED indicator
- SOLID BLUE – Standby – Charger has power and is connected to the network. Or, if in ‘plug and charge’ mode is not connected to the network, is ready to charge.
- FLASHING BLUE – Charger is connected but not charging, awaiting confirmation of charge in APP or scheduled start time
- SOLID DARK GREEN – Charger is active and Charging
- SOLID YELLOW – Charger is offline from network, check local network is active and Wi-Fi is working on the 2.4Ghz band
- FLASHING RED – Indicates the charger is in fault mode and has stopped charging for users safety
Potential causes:
» Internal RCD has tripped
» Vehicle fault
» Under or over suitable charging voltage
Remove connection to EV vehicle and reset power to the EV charger.
Electrical Installation
| Use included hole template to drill fixing holes
---|---
Ensure the supplied caps are fitted over installation screws to maintain IP
rating| Ensure correct polarity when
making incoming power connections
Ensure supplied cord grip is fitted on incoming power cable if using bottom
cable entry location| Ensure 3-pole power connector is fully inserted, then
clip power connector into the base
For dynamic load balancing,
ensure connections are made in correct polarity to CT + and CT – terminals|
We recommend completing
electrical installation testing and network set up at this stage
Snap front cover trim into place| To
remove trim, pry at shown points with a flat tool
Commercial Partner account
The charger can be upgraded to suit a commercial application with multiple
chargers and users sharing a fleet management account. – requires additional
monthly and initial set up costs.
Contact workplace@syncev.co.uk for details.
-
Scalable Software with lifetime OTA updates
Create, Add and Remove your own unlimited User Profiles. Cloud based Load Management options and OCPP integration allowing remote OTA updates through the lifetime of the product. -
Customisable Tariffs/User Groups
Multiple Tariff options such as Pay-To-Charge, Free-To-Charge, Corporate Billing/BiK/Virtual Wallet, options to set Connection Fees and/or Pre- Authorisation and ability to restrict operational hours and/or restrict charging sessions by maximum import/duration to allow charge points on your network to be tailored to any Private or Public requirement and each individual user. -
Fleet Management
Create and assign unlimited number of RFID Tags, specific to Users or Vehicles, offering the perfect means to monitor usage, cost and revenue generation within your business and export all historical data via CSV. -
Smart Reporting
Full visibility of charge point and user activity in real time, including fault notification to ensure minimal disruption to your network.
Network Setup
INSTALLER APP – Download the ‘BG EV Charging’ app here: Apple Version or Google / Android Version. Also available from the Installer Portal on the syncev.co.uk website, or using the QR codes opposite.
|
---|---
https://apps.apple.com/gb/app/bg-ev-charging/id1613505641|
https://play.google.com/store/apps/details?id=com.lucecoplc.cptool.bg
Upon powering the charger, the status indicator light will show Yellow. This
indicates that the charger is ready for network setup but is not yet connected
to the internet.
For Wi-Fi connection we recommend that the router is set to only 2.4GHz band
to reduce the risk of possible conflicts. Once setup the router can be
restored to both 2.4GHz & 5GHz bands.
-
Ensure Bluetooth is active on your device. Open the BG EV Charging App and select the Charger ID Code as shown on the charger identification label.
-
Then enter the password shown on the identification label.
We recommend this is changed during setup and noted on the identification label. -
Choose between Wifi, 4G and LAN (only one can be set).
For Wi-Fi select the SSID network name and enter password.
For LAN ensure that “LAN DHCP” is enabled.
For 4G the setting will have been pre-configured.
When connected to Wi-Fi, 4G enabled chargers will auto connect to a fall back 4G network when Wi-Fi network is lost. -
Server URL: ‘Home Charge’ for home charging or ‘Commercial for other’. ‘Manual Entry’ is for Monta or similar alternative back offices.
-
Output Current: set to max current supported by installation if less than default 32A.
-
Charge Mode: ‘APP’ for smart charging via the consumer App (see next page); ‘Plug and Charge’ for non-smart charging. Use ‘Plug and Charge’ if connection to server cannot be established and car charging is required.
-
Power Distribution Enable: If dynamic load management is required then toggle right and set sampling method to CT.
-
Maximum Current Limit: For load balancing this should be the same or less than the main fuse rating. EV charger will reduce its charging rate to limit the total home load to be under the limit. If the available current is under the minimum of 6A the EV charger will pause the charging session.
Press ‘Set’ to upload correct settings and the charger will beep to confirm.
‘Get’ will read current settings from the charger.
In less than 2 minutes, the indicator should turn from Yellow to Blue to
confirm network connection. If the charger continues to show yellow, power
cycle (switch off/on at fuse board) and reconnect via the app to check the
settings are correct.
If still unable to connect to the network but need to use the charger then
change Charge Mode to ‘Plug and Charge’ and press ‘SET’ again to re-update
settings.
If unable to establish network connection call (01952) 983 940 or email
support@syncev.co.uk
Note: The network connection from the device to the Internet is fully
encrypted and secure. Additionally, no user data is stored on the charger.
Smart Charge App Commissioning
IMPORTANT!
THE INSTALLER MUST CONNECT THE CHARGE POINT TO THE SMART CHARGING APP AFTER
INSTALLATION. SMART CHARGING WON’T WORK UNLESS YOU COMPLETE THE PROCESS BELOW:
SYNC EV APP
You will now need to inform your customer to download the SYNC EV Application
|
---|---
http://apps.apple.com/gb/app/sync-ev/id1528884639|
play.google.com/store/apps/details?id=syncev.co.uk&hl=en_GB&gl=GB
-
Once downloaded, please register an account, the chargers QR code ID and Pin code can be found on the charge point identification label on the EV charger and enclosed on the cover of the installation and user guide.
NOTE: The final step during the sign up process presents you with an option to input payment card details for Sync EV future public charging network. This is not mandatory and it can be skipped by pressing the “X” in the top left corner. -
Scan the QR code within the app, or enter the QR code number as shown on the Charger ID label to register this EV charger to the customers account.
-
Once scanned, enter the PIN code to confirm set up.
Problem connecting to the app? Contact us at support@syncev.co.uk
Alternatively, for business-hours support call (01952) 983 940
RFID Set up
To enable RFID and app authorised charging:
- Go to app options and select RFID Card
- Scan QR code of charger, then when prompted tap the RFID FOB to the front of the charger to link the fob to the charger. RFID cards can be shared over multiple chargers.
- Authorised charging – Needed for the RFID function.
Select the gear symbol on the chargerconfiguration Select Authentication and change to Required to start charging and “Save Changes”
Installation requirements
ENVIRONMENTAL PROTECTION
**** This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this
symbol is marked on a product or battery, it means that it should not be
disposed of with your general household waste. Some chemicals contained within
electrical/electronic products or batteries can be harmful to health and the
environment. Only dispose of electrical/electronic/battery items in separate
collection schemes, which cater for the recovery and recycling of materials
contained within. Your co-operation is vital to ensure the success of these
schemes and for the protection of the environment.
GUARANTEE
BG SyncEV products are guaranteed against faulty materials and workmanship for
a period of 3 years from date of delivery: products will be repaired or (at BG
SyncEV’s discretion) replacements will be supplied or (at BG SyncEV’s
discretion) a credit note will be issued.
This guarantee is subject to BG SyncEV’s conditions of sale and in particular
to the following conditions being met:
- Notification of any defect is given to BG SyncEV as soon as reasonably practicable after becoming apparent, and the products then returned to BG SyncEV.
- The products have only been operated under normal operating conditions and have only been subject to normal use.
- No work (other than normal and proper maintenance) has been carried out to the products without BG SyncEV’s prior written consent.
- The products have been assembled, or incorporated into other goods, by a qualified and recognised electrician and only in accordance with any instructions issued by BG SyncEV.
- The defect has not arisen from an item manufactured or supplied by a person other than BG SyncEV.
- 3 year warranty as standard.
- 3 years of 4G data included when used for commercial charging with the standard SyncEV smart charging app. Other smart charging apps and premium services may incur additional data costs. Top-up online to continue 4G service after 3 years.
TECHNICAL
Voltage | 220-240V ac |
---|---|
Frequency | 50-60Hz |
Rating | 6-32A output |
Wi-Fi | 2.4GHz Band b/g/n/e/i |
RCD protection | 6mA DC and 30mA AC Type A |
Wi-Fi security | WPA/WPA2/WPA2-Enterprise/WPS |
Bluetooth | 4.2 BR/EDR |
RFID | M1 compatible 13.56Mhz |
STANDARDS
Approval standard | IEC 61851-1 |
---|---|
Communication protocol | OCPP1.6J |
If you have any further technical assistance you can get in touch with our
Support Team: support@syncev.co.uk
Luceco PLC – Stafford Park 1, Telford, TF3 3BD, England | (EU) Luceco SE – C/
Bobinadora 1-5, 08302 Mataro, Spain
EV Charger | EVS7GGR.202302.GJW
www.syncev.co.uk![BG SYNCEV EVS7GGR-02 EV Charger Socketed 7.4kw Wall Charger
- icon](https://manuals.plus/wp-content/uploads/2023/05/BG-SYNCEV-EVS7GGR-02 -EV-Charger-Socketed-7.4kw-Wall-Charger-icon.jpg)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>