HYCO W79LD Series Product 2D Ring Scanner
W79LD Series Product 2D Ring Scanner
The W79LD Series Product 2D Ring Scanner is a hands-free scanner that can be worn on the index finger of either hand. It has a scanning trigger that can be activated by touching either side of the ring body with the thumb finger. The scanner comes with a charging cradle and a Bluetooth receiver.
Charging
To charge the ring scanner, connect the charging cradle to power and click the
ring scanner into the bottom of the cradle with the scan window facing up.
Ensure that the power contacts of the ring and cradle are touching. The red
light indicates that it is charging, and when the green light turns on, it is
fully charged. To remove the ring scanner from the charging cradle, hold the
middle of the ring scanner gently and pull it out upwards from the cradle.
Warning: Do not look directly into the scan window when scanning to avoid harm to your eyes.
Ring Scanner Modes
The W79LD Series Product 2D Ring Scanner has a default factory setting called SPP mode. This mode allows for charging cradle connection and program docking. If the device is connected to an IOS, Android or Windows smartphone or tablet, scan the corresponding code to read barcodes.
Bluetooth Connection
To connect with a PC, connect the cradle with the PC with USB, and scan the Bluetooth connection barcode with the ring scanner after 15 seconds. A blue light indicates successful connection. To connect with an Android smartphone or tablet, find the Bluetooth connection barcode on the side of the cradle, scan it with the ring scanner, and change the Bluetooth name to the serial number so that the device can be found. Then open the ‘Bluetooth Search’ at the setting menu, find the Bluetooth serial number in the list and connect. A green light indicates a successful connection.
Specifications
- Model: W79LD
- Scanner Resolution: 1280×800 pixels
- Code Reading: 5 meters
- Scanning Distance: 5 meters long-distance scanning
- Weight: 20g (without strap)
- Dimensions (WDH): 38.6mm29.0mm22.1mm
- Ring Straps: 10 pcs in different sizes
- Bluetooth: BT4.2, BLE
- LED Indicator: RGB LED (programmable)
- Vibration Indicator: Supported
- Battery: 200mAh@3.7V
- Charging Cradle Battery: With USB dongle and Bluetooth adapter
- Battery Life: 8 hours (when fully charged with 100cm depth of field, and scanning once every 5 seconds)
- Scanning Trigger: Touch-to-scan
- IP Level: IP66
- Drop Test: 3 meters
- Operating Temperature: -10 to 50 (14 to 122)
Disclaimer
Disclaimer @2018 Shanghai Hyco Genyong Technology Co., Ltd. All rights
reserved.
Please read through the manual carefully before using the product and operate
it according to the manual. It is advised that you should keep this manual for
future reference.
Do not disassemble the device or remove the seal label from the device.
Otherwise, Shanghai Hyco Genyong Technology Co., Ltd. does not assume
responsibility for the warranty or replacement. All pictures in this manual
are for reference only and actual product may differ. Regarding to the product
modification and update, Shanghai Hyco Genyong Technology Co., Ltd. reserves
the right to make changes to any software or product to improve reliability,
function, or design at any time without notice. Besides, the information
contained herein is subject to change without prior notice. The products
depicted in this manual may include software copyrighted by Shanghai Hyco
Genyong Technology Co., Ltd. or a third party. The user, corporation or
individual, shall not duplicate, in whole or in part, distribute, modify,
decompile, disassemble, decode, reverse engineer, rent, transfer or sublicense
such software without prior written consent from the copyright holders. This
manual is copyrighted. No part of this publication may be reproduced or used
in any form without written permission from Hyco.
Please visit www.hycoglobal.com or check the
latest version of the specification sheet for the latest product information.
Design
Ring Scanner
- Wearing: wear on index finger on left or right hand
- Scanning: touch either side of ring body with thumb finger to trigger the scanning
Ring scanner charging cradle Bluetooth Receiver)
Charging
Charging Ring Scanner
Charging Illustration 1
Charging Illustration 2
- Connect the Ring scanner charging cradle to power, click the ring scanner into the bottom of cradle with the scan window upward. Please note the power contacts of the ring and cradle must be touched.
- The red light indicates it is in charging, when the green light turns on, it’s finished charging.
Warning: don’t look straightly into the scan window when scanning in case of harm to eyes.
Take the Ring Scanner out of the Ring scanner charging cradle
Hold the middle of the ring scanner gently and pull out upward from the
cradle.
Ring Scanner Modes
SPP Mode (default factory settings)
Charging cradle connection and program docking mode
Common ****
To connection with PC via USB cradle, scan COMMON code, and scanning barcode
is available. (Random terminal system is acceptable with the cradle)
In this protocol transmission mode, if you need different system programs
docking, please get the relevant development SDK at the official website or
contact the relevant agent technical support.
HID Mode
Use the terminal device directly. Output barcodes in HID keyboard mode
searched by default Bluetooth. According to the actual system, scan the
barcode corresponding to the system and connect.
IOS
If the device is connected to IOS smart phone/tablet, scan the IOS code to read the barcodes.
ANDRIOD
If the device is connected to ANDROID smart phone/tablet, scan the ANDROID code to read the barcodes.
WINDOWS
If the device is connected to WINDOWS smart phone/tablet, scan the WINDOWS code to read the barcodes.
Bluetooth connection
Connect with PC:
Connect the cradle with the PC with USB, and the green light means normal
connection. After 15 seconds, scan the Bluetooth connection barcode with the
ring scanner, and a blue light indicates successful connection.
Connect with Android smart phone/tablet
First, find the Bluetooth connection barcode on the side of the cradle, scan
it with the ring scanner, and change the Bluetooth name to the serial number
so that the device can be found;
Then open ‘Bluetooth Search’ at the setting menu, find the Bluetooth serial
number in the list and connect. Green light indicates successful connection.
Components
Components | Quantity | Usage |
---|
**** Ring Scanner
| ****
1
| .Reading Barcodes/2D codes 2.Bluetooth slave
**** Ring Cradle
| ****
1
| Charging cradle 2.Bluetooth receiver
Charging Adapter
| ****
1
| Connect adapter to power with USB cable
****USB cable
| ****
1
| .Connect charger to USB port 2.Connect charger to charging adapter
Ring Strap (Swappable)
| ****
1
| 10 pcs in different sizes
Certificate
| ****
1
| Factory certification
User Manual
| ****
1
| Device description and usage instruction
Product Specifications
Model | W79LD |
---|---|
Scanner | HYCO CMOS-Sensor Scanner |
Resolution | 1280×800 pixels |
Code Reading | 5 meters barcodes/2D codes reading |
Scanning Distance | 5 meters long-distance scanning |
Weight | 20g (without strap) |
Dimensions (WDH) | 38.6mm29.0mm22.1mm |
Ring Straps | 10 pcs in different sizes |
Bluetooth | BT4.2, BLE |
LED Indicator | RGB LED (programmable) |
Vibration Indicator | Supported |
Battery | 200mAh@3.7V |
Charging Cradle | With USB dongle and Bluetooth adapter |
Battery Life | 8 hours (when fully charged with 100cm depth of field, and |
scanning once every 5 seconds)
Scanning Trigger| Touch-to-scan
IP Level| IP66
Drop Test| 3 meters
Operating Temperature| -10℃ to 50℃ (14℉ to 122℉)
Humidity| 0%-95%RH (non condensing)
Note: For Ring Scanner and Ring scanner charging cradle, operating temperature is -10°C to 50°C
The technical specifications of this product are subject to change without notice.
Functions
Scanning
Wear on left or right index finger, touch left or right side of ring and aim
at the barcode, the ring light turns green, it starts to scan.
Ring Straps
Firstly, straightly pull out ring strap from the slot, then choose another
ring strap and push it to the top of slot.
Ring Indicator
- The green light indicates successful scanning.
- The red light flashing indicates low battery.
- The green light keeping on for 1 second indicates successful Bluetooth connection.
- The blue light keeping on for 1 second indicates Bluetooth disconnection.
- The red, green and blue light flashing indicates restarting.
Bluetooth can’t connect
Normally, if the Bluetooth light doesn’t turn on, user can scan the barcode “Reset Bluetooth Name”, wait for 10 seconds, and reconnect.
Reset Product Name
Restore Factory Setting
Scan the barcode “Restore factory settings”, the ring will disconnect Bluetooth connection with terminal devices, and all the settings will change to factory default.
Charging cradle light indicator
The blue light indicates successful Bluetooth connection between ring scanner
and cradle.
The red light off while the green light on in charging indicates fully charged.
Wake up ring in charging
The ring doesn’t work when in charging, while it could be waked up by touching
either side of ring three times.
Laser calibration
If laser length changes longer or shorter, please stop scanning, touch ring
for 4 seconds once and repeat several times to get it right. If it’s still
abnormal, please scan the barcode “Automatic calibration”.
Restore Factory Setting
After scan the barcode “Automatic laser calibration”, the ring turns on purple, put it on the table, wait for 15 seconds until the purple light turns off. The ring laser is calibrated right and functions normally.
Code system on/off
- Basic setting. 4 default code systems on: EAN13, EAN128, CODE128, CODE39; in which CODE128 and CODE39 read at least 2 characters;
- Extended setting. 9 default code systems on: EAN8, EAN13, EAN128, UPCA, UPCE, CODE128, CODE39,CODE93, ITF25; in which CODE128 reads at least 1 character; ITF25 only reads 14 characters as default.
If a code system and code length are not included please contact technical support and local distributor.
Touch switches on both sides
The touch switch on the left and right sides of the ring scanner are both on
by default. If you need to turn off one side, please use the following
barcodes to turn it on/off.
Service
Warranty: one year for ring scanner, half year for battery and accessories.
Notice
- The ring window must be kept clean. Improper usage will breach the limited warranty clause.
- Avoid rough objects scratching the window.
- Remove stains from window by soft cloth.
- Do not spray any liquid onto the window.
- Use cleaning water to clean.
Function barcodes setup
Change function of scanning after scanning the following barcodes:
Device information
“Device information” barcode includes device information (e.g. serial number, version number, Bluetooth version information).
Vibration open
Vibration close
Scan function code “Vibration Open” to activate vibration function, Scan function code “Vibration close” to close vibration function,
Slow down data transmission through ring cradle
HYCO-W79LD-Series-Product-2D-Ring-Scanner-23
In HID mode, scan the barcode “Speed up data transmission through ring cradle”, it can accelerate the data transmission speed between the cradle and computer; scan the barcode “Slow down data transmission through ring cradle”, it can slow down the data transmission between the cradle and computer.
Triggered continuous scanning
Scan the barcode “Triggered continuous scanning”, ring could keep scanning when user keeps touching the ring. If user wants to change to common scanning, scan the “Manual Trigger Mode” bar code.
Manual Trigger Scanning
“Manual Trigger Mode” is set by default, user needs to touch ring once to scan once.
Automatic Interval Scanning
W79LD Series Product 2D Ring Scanner User Manual
After scan “Automatic interval scanning” bar code, ring could automatically scan every 0.5 ~ 3 seconds without touching (2 seconds by default)
Automatic interval scanning-reduce
After scan “Automatic interval scanning-reduce” barcode, it can expedite the scanning speed once by 0.5 second, the fastest scanning speed is scanning once every 0.5 second.
Automatic interval scanning-increase
After scan “Automatic interval scanning-increase” barcode, it can slow down the scanning speed once by 0.5 second, the slowest scanning speed is scanning once every 3 seconds.
Scan angle adjustment
According to different barcode length, user needs to change laser length to
achieve better scanning effect.
-
Scan “Laser calibration” barcode to activate the function, the ring light turns white and begins to automatically and intermittently scan.
Laser calibration -
After scan “Widen” barcode, the laser length becomes long; after scan “short ” barcode, the scan angle becomes short.
Extend laser
Shorten laser
Note: do not extend or shorten more than 10 times one time.
-
Scan “Confirm” barcode, the ring light turns yellow and white, the laser length is confirmed.
Laser confirm -
Scan “Data generation” barcode, the ring light turns yellow and red, and then turns purple for a while. The laser length is set successfully after the purple light turns off.
Data generation
Common functional barcodes
To meet different needs for customers, there are some functional barcodes used to meet the requirements for different customers.
Add Enter
Delete Enter
After scan “Add Enter” barcode, it can automatically move to next line in the
text field after each scanning. If user wants to close the function, scan
“Delete Enter” barcode.
After scan “Add the tab” barcode, it can automatically move to next line in
excel after each scanning. If user wants to lose the function, scan “Delete
the tab” barcode.
Add TAB
Delete TAB
HYCO Technology
Website: www.hycoglobal.com
Email: global_sales@hycoiot.com
Phone Number: +86 15201965826