PRECAUTIONS AND WARNINGS

  • Avoid sunlight and do not use the product in humid environments.
  • Avoid high-temperature places
  • Avoid excess dust.
  • Do not install the product near sources of heat.
  • Use the product in places with good ventilation, and follow the instructions in this manual for its installation.
  • Use a dry doth to clean the UPS if necessary.
  • In case of fire use a dass C fire extinguisher.
  • Verify proper grounding for your personal and UPS regulator safety.
  • This device is designed for computer equipment and networks. We do not recommend using this product for high risk, vital or medical systems.
  • Do not use the UPS with excessive loads.
  • The UPS length of the output line must not be greater than 10m.
  • Do not open the UPS, it may cause damage to the battery. Contains substances such as acids and can cause damage to the eyes or skin.
  • Use plenty of water to wash immediately. In an emergency, see a doctor.
  • Do not expose the battery to fire to avoid explosion and personal injury.
  • Do not connect power sources or extensions to current outlets.
  • Do not connect the printer or any other device to a computer.
  • Avoid spilling liquids on your device, they can cause it to malfunction.
  • Using this device under conditions other than normal may cause electricshock.
  • Do not throw away a battery, dispose of it according to local regulations, or return it to the change at the place where you purchase the new spare part.

KNOW YOUR DEVICES

INSTRUCTIONS FOR USE

  1. Leave at least 2.5 cm of space around the UPC for proper ventilation.
  2. Connect the equipment to the UPS outputs.
  3. Connect the UPS to the AC input line (check the earth ground line).
  4. Press the Power switch; UPS delivers a stable voltage output when the battery is in good condition.
  5. Turn on your computer or device.
  6. In case of failure or overload, the UPS enters battery mode, the LED flashes yellow and a beep is heard. Turn off the UPS and other connected devices. The UPS will auto-reset when it recovers if the UPS is turned off by low battery.
  7. Press the power switch to turn it off if necessary.
  8. The UPS will automatically reset if it is shutdown due to low battery.

Maintenance:
UPS uses a regulating valve for acid batteries. To increase its charging lifetime. The UPS will charge the battery when the input line is present.

Note: High temperatures shorten battery life. The efficiency of the battery deteriorates even if it is not used.

How to check the battery

  1. Connect the input line and charge the battery for more than 8 hours.
  2. Turn on the UPS and connect the load.
  3. Disconnect the input line to discharge the battery until it turns off.
  4. Check the download time. When the discharge time is less than half, change the battery.

Note: The load capacity is calculated in Watt. If the battery is damaged, replace it with a new one with the same characteristics

UPS STORAGE

Connect to the power line for at least 4 to 5 hrs. Before storing the UPS. Turn off the power and turn off the UPS and place it in a dry and ventilated area. If you are going to store the UPS for long periods of time, you must charge it for time intervals.Vorago-UPS-400-Backup-Battery-6-Connectors-
FIG-3

PROBLEM RESOLUTION

If the UPS fails to operate, review the following steps before calling your service center.

Problems > Possible causes and solutions
UPS does not switch to mode line. Ignition UPS. LED blinks yellow and the buzzer beeps by time intervals> Line input failed. If you change contact. The input line is at its nominal value. There is no voltage out put in battery mode. When the input line fails, UPS shuts down> Is the battery damaged or properly connected. When the input line is connected, charge the battery for 8 hrs. If the problem persists, the battery is damaged or the charger is damaged, contact your dealer. Yellow LED flashes and buzzer beeps on and off> Battery voltageis low, charge battery for 8 hrs. Continuous, when the input line is normal. Red LED and buzzer beeps continuously> The UPS is overloaded. Check the load capacity and disconnect some connections

TECHNICAL SPECIFICATIONS

Limited product warranty

Vorago equipment and / or accessories are covered by a limited warranty for the time indicated in the annexed validity table, counting from the date of acquisition, against any manufacturing and operation defect, provided they have been used under normal conditions of use during the warranty period and for which it was manufactured. Vorago quarantees the buyer the absence of anomalies regarding the materials.Vorago-UPS-400-Backup-Battery-6
-Connectors-FIG-5

Responsibilities
The total responsibility of Vorago will be to repair or replace the product, including labor and parts, at no cost to the buyer when it is returned to the point of sale, presenting this warranty policy properly completed and stamped by the establishment where it was purchased. The product or copy of the receipt or receipt or invoice, in which data of the product the date of purchase is specified, to verify the times within the guarantee. Vorago may use new parts, restored or used in good condition to repair or replace any product, at no additional cost to the consumer. In the case of equipment and / or accessories that can not be repaired, the change will be generated by a similar product or with superior characteristics. This warranty covers the transportation expenses of the product derived from its fulfillment; which will be directly attributable to the supplier of the product. In all replacement products, the original warranty period will be renewed. Vorago is governed by international standards for the manufacture of products.

How to obtain warranty support
Warranty claims are processed through the point of sale, during the first 15 days after the purchase, as long as they meet the requirements. Warranty claims that can not be processed through the point of sale and any concerns related to the product purchased should be sent with the prepaid guide by Vorago to the address of the Vorago headquarters in Francisco Villa No. 3, Col. San Agustin, CP 45645, Tlajomulco de ZĂșniga, Jalisco, Mexico.Except in situations of force majeure or fortuitous event, the repair time in no case will be greater than 30 calendar days from the date of receive of the equipment in Vorago.

Exclusions
This warranty is not valid in the following cases:

  • When the product has been used in conditions other than normal.
  • When the product has not been operated in accordance with the instructions of use.
  • When the product has been altered or repaired by unauthorized persons by Vorago.

Vorago does not offer any other express warranty for this product. To make the warranty valid, as well as the acquisition of parts, components, consumables and accessories
To validate a guarantee, the following information must be sent to the email: garantias@voragolive.com

  1. Model and color
  2. Product failure
  3. Ticket or purchase invoice (digitized)
  4. Your address with CP, telephone and full Name.

Available in the establishment where the product was purchased and/or in our central offices: