HYTRONIK HHC2045 Tunable White LED Driver Instruction Manual
- June 11, 2024
- HYTRONIK
Table of Contents
HYTRONIK HHC2045 Tunable White LED Driver
Installation and Instruction Manual
Tunable White LED Driver – HHC2045
Technical Specifications
- Mains Voltage: 220~240VAC 50/60Hz
- Mains Current Input: 0.22~0.2A
- Power Factor: 0.95
- Max. Efficiency: 85%
- Dielectric Strength: InputOutput : 3000VAC
- Leakage Current: < 0.25mA
- Power/Current/ Voltage Range (HHC2045):
- 20W/350mA/10~56V
- 28W/500mA/10~56V
- 39W/700mA/10~56V
- 45W/900mA/10~50V
- 42W/1050mA/10~40V
- 41W/1200mA/10~34V
- Output:
- 50W/1.05A/12-48V
- Channel 1 (CH1) + Channel 2 (CH2) = 45W max.
- CH1 = Cool white
- CH2 = Warm White
- Environment Safety and EMC:
- Ripple Current: Uout Max.
- Turn-on Time:
- Operation Temp.:
- Case Temp. (Max.):
- IP Rating:
- EMC standard:
- RED standard:
- Safety standard Certifications:
Product Usage **
**
To use the Tunable White LED Driver HHC2045, please follow these instructions:
- Connect the driver to a power source with a mains voltage of 220~240VAC and a frequency of 50/60Hz.
- Connect the LED lights to the output channels on the driver. Channel 1 (CH1) is for cool white lights, and channel 2 (CH2) is for warm white lights. The maximum total output power of both channels combined should not exceed 45W.
- Use the power/current/voltage range options on the driver to adjust the output power to the desired level. The available options are: – 20W/350mA/10~56V – 28W/500mA/10~56V – 39W/700mA/10~56V – 45W/900mA/10~50V – 42W/1050mA/10~40V – 41W/1200mA/10~34V
- Use the turn-on time and operation temperature options to adjust the driver’s settings based on your specific needs.
- Ensure that the case temperature does not exceed the maximum specified limit.
- The driver has an IP rating for safety against moisture and dust, and meets EMC and RED standards for safety and certification.
Technical Specifications
Input
| Mains Voltage| 220~240VAC 50/60Hz
---|---|---
Mains Current| 0.22~0.2A
Power Factor| 0.95
Max. Efficiency| 85%
Dielectric Strength| Input→Output : 3000VAC
Leakage Current| < 0.25mA
Output
| Power/Current/ Voltage Range (HHC2045)| 20W/350mA/10~56V 28W/500mA/10~56V
39W/700mA/10~56V 45W/900mA/10~50V 42W/1050mA/10~40V 41W/1200mA/10~34V
Power/Current/ Voltage| 50W/1.05A/12-48V
Output power handling| Channel 1 (CH1) + Channel 2 (CH2) = 45W max.
Output channel function| CH1 = Cool white CH2 = Warm White
Ripple Current| <3%
Uout Max.| 75V
Turn-on Time| < 0.5s
Environment
| Operation Temp.| Ta: -20 ~ +45℃
Case Temp. (Max.)| 85℃
IP Rating| IP20
Safety and EMC
| EMC standard| EN55015, EN61547, EN61000-3-2, EN61000-3-3
RED standard| EN300328, EN301489-1, EN301489-17
Safety standard| EN61347-1,EN62493,EN61347-2-13
Certifications| CB, CE , EMC, RCM
Installation
Mechanical Structure & Dimensions
Note: Connecting a sensor antenna will disable the com input on the driver.
- COM inputs: HHC2045 is not standard DT8 tunable white driver, it is not DALI addressable but it can achieve colour tuning and dimming via DALI broadcast.
Wiring Diagram
Antenna Connections (Sensor-Dim)
Com Connections (When used together with Hytronik DALI motion sensors)
Switch-Dim Connections
Wire Preparation
Solid or Stranded wire type 0.75 – 1.5mm2.
To make or release the wire from the terminal, use a screwdriver to push down
the button.
Loading and In-rush Current
Inrush Current (Imax.) | 53A |
---|---|
Pulse Time | 36 s |
Circuit Breaker Information
Automatic circuit breaker type | B16A | B10A | B13A | B20A | B25A |
---|---|---|---|---|---|
HHC2045 | 43 | 27 | 35 | 54 | 67 |
The data above is calculated according to the formula: Maximum Amount =
16/(Pn/230). In order to provide a more reliable reference in real
application, the data have been revised to take 60% of the number calculated,
i.e.
16/(Pn/230) x 60%. Please kindly take note that the calculation is based on
ABB circuit breaker series S200. Actual values may differ due to different
types of circuit breaker used and installation environment.
Load distribution
Each channel can supply the maximum load and white balance can be controlled
as such:
Model | Colour Temperature | Cool White | Neutral White | Warm White |
---|---|---|---|---|
HHC2045 | Power Distribution | CH1=45W, CH2=0W | CH1=22.5W, CH2=22.5W | CH1=0W, |
CH2=45W
Dimming Interface Operation Notes
Switch-Dim
The provided Switch-Dim interface allows for a simple dimming method using
commercially available non-latching (momentary) wall switches. Detailed Push
switch configurations can be set on Koolmesh app.
Switch Function | Action | Descriptions |
---|---|---|
Push switch | Short press (<1 second) | |
* Short press has to be longer than 0.1s, or it will be invalid. |
- Turn on/off
- Recall a scene
- Turn on only
- Quit manual mode
- Turn off only
- Do nothing
Double push|
- Turn on only
- Quit manual mode
- Turn off only
- Do nothing
- Recall a scene
Long press (≥1 second)|
- Dimming
- Colour tuning
- Do nothing
Sensor-link (VFC signal only)| /| Upgrade a normal on/off motion sensor to a
Bluetooth controlled motion sensor
Emergency Self-Test Function| Short press (<1 second)
-
Short press has to be longer than 0.1s, or it will be invalid.|
- Start Self test (Monthly) – Start Self test (Annually)
- Stop Self test
- Invalid
Long press (≥1 second)|
- Start Self test (Monthly)
- Start Self test (Annually)
- Stop Self test
- Invalid
Fire Alarm (VFC signal only)| Refer to App User Manual V2.1|
- Able to connect the Fire Alarm system
- Once the fire alarm system is triggered, all the luminaries controlled by the Push Switch will enter the preset scene (normally it’s full on), after the fire alarm system gives the ending signal, all the luminaries controlled by this Push Switch will revert back to normal status.
Additional Information / Documents
-
To learn more about detailed product features/functions, please refer to
www.hytronik.com/download->knowledge->Introduction of App Scenes and Product Functions -
Regarding precautions for LED driver installation and operation, please kindly refer to
www.hytronik.com/download->knowledge->LED Drivers -Precautions for Product Installation and Operation -
Regarding precautions for Bluetooth product installation and operation, please kindly refer to
www.hytronik.com/download->knowledge->Bluetooth Products – Precautions for Product Installation and Operation -
Data sheet is subject to change without notice. Please always refer to the most recent release on
www.hytronik.com/products/bluetoothtechnology ->Bluetooth Drivers -
Regarding Hytronik standard guarantee policy, please refer to
www.hytronik.com/download->knowledge->Hytronik Standard Guarantee Policy
Subject to change without notice.
HHC2045-20230302-A0
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>