Thermogroup TR5585 Thermorad In Wall Heater Installation Guide

June 11, 2024
Thermogroup

Thermogroup TR5585 Thermorad In Wall Heater Installation Guide

Thank you for your purchase

Thank you for choosing a Thermogroup product.
This document will provide a step-by-step guide to a perfect installation as well as details on the warranty and how to get technical support should you need it.
To ensure a safe, hassle-free installation to be proud of, please take the time to read this guide in full before you start. We’ve taken the time to highlight the below key installation information as well as provide step-by- step installation images to make it easy for you to get the job done.
If you have any questions about your Thermorad Panel call our technical support team on 1300 989 464. We will do our best to find a solution and will always give that little bit extra…
Thanks again for choosing a Thermogroup product.

Key Installation Information

Your completed installation should look like the buildup shown opposite. Make sure the panel is mounted flush with the surface of the wall frame so there is no air gap between the panel and the back of the wall sheet.
Make note of the location of the panel and ensure all fixings are installed outside the panel area to ensure the fixings do not penetrate the panel.
Ensure the supply lead is prewired or run to an access point prior to the wall being sheeted.
All electrical work must be completed by a qualified electrician in accordance with any local regulations.
All modification to the framework and reinforcing of the framework to accommodate the panel is the responsibility of the installer.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance
Means for full electrical disconnection must be incorporated in the fixed wiring installation in accordance with the wiring rules.
The supply cord into the appliance cannot be replaced. If the cord is damaged the appliance should be scrapped and replaced.

Installation Information

1. Plan out the installation
Your completed installation should look like the buildup shown opposite. Make sure the panel is mounted flush with the surface of the wall so there is no air gap between the panel and the back of the wall sheet

.

2.Modify the framework
Begin by making a 555mm wide space in the wall to accommodate the Thermorad. If the stud spacing is 600mm centre-to-centre Thermorad should fit directly between the studs.

3.Fix studs above the Thermorad
It is recommended to include fixing in the wall above the Thermorad to provide a suitable mounting for your towel rail to fix to.

4.Reinforce the framework
Once your frame modifications have been completed you may need to reinforce the framework work with additional timber if required.

5. Dual setup for rails over 650mm wide For rails over 650mm wide we recommend the use of two Thermorad panels to increase the heating area. Having a stud running between the two Thermorad’s provides an anchor point for the wall sheeting to be fixed

6.Make provision for the power lead
The power supply comes out of the top of the unit. Identify where the power lead will be running to connect to the power supply or timer and make appropriate provision for running the cable. 7.Place 7.the Thermorad in position
Sit the Thermorad in the wall cavity ensuring that the aluminium face marked front is facing out. Ensure the panel is flush with the wall frame surface so there is no cavity created between the panel and the wall sheet when it is sheeted.

8.Fix the Thermorad in position
Fix the Thermorad in position by screwing through the fixing holes provided at the top and bottom of the unit. Ensure the face of the unit is flush with the front face of the stud.

9. Sheet the wall
Sheet the wall over the Themorad panel. Make sure you mark the exact location of the panel and the studs onto your sheet so that you don’t accidently fix into the panel and damage it.

10.Tile or Paint the wall
Tile or paint the wall to complete your bathroom.


11.Mount the rail
Mount the rail onto the wall ensuring you leave a minimum of 50mm space above the top of the Thermorad before fixing the rail so as not to mount into the panel.

12. Connect to the power supply
Connect the Thermorad panel lead into the incoming power supply or timer. This work must be undertaken by a qualified electrician and it is important to ensure any electrical connections are accessible.

Warranty Information

Thermogroup covers all its products with a satisfaction guarantee. In addition, Thermogroup will supply a replacement product where a fault is shown to be caused by manufacture, materials or workmanship providing the goods have been installed correctly and according to installation instructions. This guarantee does not include removal, freight or installation costs. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
The Thermorad TR5585 has a 10 year warranty. To use the warranty the customer must provide a proof of purchase.
If the product develops a fault within the warranty period due to normal wear and tear, Thermogroup at its discretion will recognise whether it’s a faulty product or not. If it is impossible or not economical for the manufacturer to repair the product, the manufacturer will replace the faulty product with a new unit of the same model.
The repair service offered within the warranty period only covers the faults and problems as developed from the manufacturer’s errors. Any damage caused by improper use, carelessness or incorrect wiring is not covered.
Thermogroup is not responsible for any monetary loss or injuries caused by improper use of this product.
Design is Patent Pending – 2022201917

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Thermogroup User Manuals

Related Manuals