turbionaire Lisa 60 WALL BLACK Kitchen Cooker Hood
SAFETY INSTRUCTIONS
- Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
- The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage (V) and the frequency (Hz) in your home.
- The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
- Never let children operate the cooker hood.
- The cooker hood is for home use only. It is not suitable for barbecues, Roast shop and commercial purposes.
- The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
- Before cleaning, switch the power off at the main supply.
- Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
- Prohibit putting the cooker hood by fire.
- If there is any fault with the appliance, please call the service department to request a service engineer.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The instructions shall state the substance of the following: there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.
Important Hints on Installation
- The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Regulations concerning the discharge of air have to be fulfilled.
Important notes about the extraction mode
WARNING
Risk of poisoning from exhaust gases sucked back. Never operate the device in
extraction mode simultaneously with an open flue appliance when there is not
adequate airflow guaranteed.
Open fl ue combustion equipment (for example, gas, oil, wood or coal-fi red heaters, tankless water heaters, water heaters) pulls combustion air from the room and runs it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor air is removed from the kitchen and the adjacent rooms – without suffi cient air intake this creates a vacuum. Toxic gases from the chimney or extraction fl ue can thereby be sucked back into the living spaces.
- Always ensure that a suffi cient supply of fresh air is guaranteed and that the air can circulate.
- An air supply / extractor box alone does not ensure compliance with the limit value.
Safe operation is only possible when the negative pressure in the room where
the appliance is located does not exceed 4 Pa (0.04 mbar). This can be
achieved when the air required for combustion can fl ow through openings that
are not closable, for example in doors, windows, in conjunction with an air
supply/ extractor box or through other technical measures. In any case,
consult a qualifi ed chimney sweep who can assess the entire ventilation of
your house and propose appropriate measures for adequate ventilation.
If the hood is used exclusively in the recirculation mode, unrestricted
operation is possible.
WARNING
Fire hazard from flying sparks. Only install equipment on a fi replace for
solid fuels (for example, wood or coal), if a closed, non-removable cover is
available.
DIMENSIONS
Model No.: LISA 60 WALL BLACK – Product Code: TIS60WB
N.W.:14.5 kg G.W.:16.5 kg
INSTALLATION
Note: When the range hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must be not exceed 4 Pa (4 x 10-5 Bar).
Required minimum distance hood to
- Ceramic-glass rings/hotplates: 65 cm
- Gas cooker: 75 cm
- Coal / oil / stove wood firing: 85 cm
Installation Steps
Note: Do not connect the power cable until the installation is complete! Get a
second person to help you with the installation.
-
Drill 3 holes (Φ8mm to adapt your wall plugs) to place the bracket. Screw and tighten the bracket to the wall with the screws 3 Screws (ST4x30mm) and 3 wall plugs (not supplied).
-
Place the range hood and hook it by using the two notches on the wall bracket.
-
Slide the upper shaft part into the lower one
-
Attach the shaft bracket to the lower / outer shaft part
-
Place the shaft on the hood body and mark the mounting holes on the wall.
-
Remove the shaft and drill the holes at the marked points.
-
For exhaust air operation of the hood, attach the exhaust hose to the air outlet of the hood body.
-
Re-attach the exhaust shaft onto the hood body, passing the exhaust hose through the shaft and connecting it to the exhaust opening if needed.
-
Fix the lower shaft bracket to the wall with 2 plugs and screws (4 x 30 mm).
-
Pull out the upper / inner shaft part to the desired height upwards, mark the mounting holes for the upper shaft bracket on the wall and pre-drill the marked points.
-
Make sure that the lower end of the outer shaft part rests on the hood body. It is not necessary to screw the shaft to the hood body.
Installation of the carbon filter – CODE: TCF1 (not included)
Technical data
Value | Unit | |
---|---|---|
Lighting efficiency class | A | |
Air flow (3’rd speed/ 2’nd speed/ 1’st speed) | 653.2/ 559.6/ 294.1 | m³/h |
Electric power input | 123 | W |
Nominal power of the lighting system | 3 | W |
Sound power level – boost
Sound power level – high Sound power level – low
| 67| dB
65| dB
48| dB
Energy Efficiency class| A++|
Annual Energy Consumption| 26.8| kWh/a
Connection diameter – minimum| 120| mm
FUNCTIONS
CAUTION! The lamp must not be covered by thermal insulation or other
materials.
NOTICE! Only switch on the lights while the appliance is operating. Do
not switch on the lights to lighten the room.
Do not touch the illuminant within 30 minutes after using the appliance.
LISA 60 WALL BLACK
- ON/OFF – Used for turning ON/OFF the fan
- Speed plus key – For increasing the speed of the fan, Long Press this Icon for Booster setting
- Speed decrease key – For decreasing the speed of the fan.
- Light Key
- Digital display – Fan speed display: 1-for Low Speed, 2- for Medium Speed, 3- fot High Speed
Quick timer: Pres + & – simultaneously for 1 second. The digital display flashes & the countdown starts for 5 minutes. After 5 minutes, the motor and light will turn off automatically and the buzzer sound will keep buzzing for 5 seconds if there are no other operations, the buzzer sound can be stopped by depressing any button during the buzzing. If need to stop this function during the countdown, pres + & – simultaneously for 1 second again.
TROUBLESHOOTING
Fault | Cause | Solution |
---|---|---|
Light on, but fan does not work | The fan blade is jammed. | Switch of the unit |
and repair by qualified service personnel only.
The motor is damaged.
Both light and fan do not work| light bulb burn.| Replace the bulb with
correct rating.
Power cord looses.| Plug in to the power supply again.
Serious Vibration of the unit| The fan blade is damaged.| Switch of the unit
and repair by qualified service personnel only.
The fan motor is not fixed tightly.
The unit is not hung pro-perly on the bracket.| Take down the unit and check
whether the bracket is in proper location.
Suction per-formance not good| Too long distance between the unit and the
cooking plane| Readjust the distance to 65-75cm
STAINLESS STEEL SURFACES CLEANING
To avoid damaging the stainless steel surface of your appliance
Always clean with:
Soft cloths, distilled or filtered water, as well as detergents specially made
for stainless steel.
Do not clean with:
Abrasive materials, cleaning powders, bleach and other chlorine-based
products, ammonia-containing glass cleaners, tap water especially if it tends
to be hard water, oven cleaners.
Damage to stainless steel surfaces due to the use of improper cleaning
substances is not covered by the warranty.
HINTS ON DISPOSAL
According to the European waste regulation 2012/19/EU this symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailled information about recycling of this product, please contact your local council or your household waste disposal service.
Producer & Importer:
INTAX TRADING SRL. 14B Ion Creangă Str., Otopeni, Ilfov, România Tel (+40) 318
246 246. Fax (+40) 214 203 151
office@intaxtrading.com
www.intaxtrading.com
References
- Dehumidifiers, Portable Air Conditioners| Intax Trading
- Dehumidifiers Fans Air Conditioners| Turbionaire