AS5247 Socket Board
AS5247-MF_EK_SB Socket Board
The AS5247-MF_EK_SB socket board is designed for quick programming of AS5247 magnetic rotary position sensors without the need for soldering. This board can be used with the USB I&P Box or the SD4Y production programmer.
Kit Content
The kit includes one AS5247-MF_EK_SB socket board.
Board Description
The AS5247-MF_EK_SB socket board features a ZIF Open-Top-Socket for MLF packages in the middle of the PCB. Pin 1 of the IC is indicated by a small dot on the right bottom corner of the socket or by the label on the PCB. The PCB offers two connecting options, a 5-pin dual-row connector on the left side for connecting to the USB I&P Box and a 10-pin dual-row connector on the right side for connecting to the SD4Y Production Programmer. All passive components required for proper operation are included on the PCB, and only a power supply mode of 5V is possible.
Figure 2: AS5247 socket board
- ZIF socket for MLF
- Connector for USB I&P Box
- Connector for SD4Y Programmer
Figure 3: open ZIF socket
AS5247-MF_EK_SB Hardware
AS5247-MF_EK_SB Schematics
AS5247-MF_EK_SB PCB Layout
Ordering & Contact Information
The ordering code for the AS5247-MF_EK_SB socket board isAS5247-MF_EK_SB.
Technical support is available at www.ams.com/Technical-
Support, and our products are available
for purchase or free sample requests at
www.ams.com/ICdirect.
Product Usage Instructions
To use the AS5247-MF_EK_SB socket board, follow the steps below:
- Connect the board to a power supply mode of 5V.
- Connect the USB I&P Box or the SD4Y Production Programmer to the appropriate connector on the board.
- Insert the AS5247 magnetic rotary position sensor into the ZIF socket on the board. Ensure that Pin 1 of the IC matches the small dot on the right bottom corner of the socket or the label on the PCB.
- Program the AS5247 sensor using the USB I&P Box or the SD4Y Production Programmer.
Introduction
The AS5247-MF_EK_SB socket board is used for quick programming of AS5247
magnetic rotary position sensors without soldering due to its ZIF socket.
This board can be used in combination with the USB I&P Box or the SD4Y
production programmer.
Kit Content
Figure 1: Kit content
Pos. Item Comment
1 AS5247-MF_EK_SB Socket board
Board description
The PCB offers 2 connecting options: The 5-pin dual-row connector on the left side for connecting to the USB I&P Box and the 10-pin dual-row connector on the right side for connecting to the SD4Y Production Programmer.
A ZIF Open-Top-Socket for MLF packages is mounted in the middle. Pin 1 of the
IC is indicated by a small dot on the right bottom corner of the socket or by
the label on the PCB.
All passive components needed for proper operation are included on the PCB.
Only a power supply mode of 5V is possible.
AS5247-MF_EK_SB Hardware
AS5247-MF_EK_SB schematics
Figure 4: AS5247-MF_EK_SB schematics
AS5247-MF_EK_SB PCB layout
Figure 5: AS5247-MF_EK_SB PCB layout
Ordering & Contact Information
Ordering Code Description
AS5247-MF_EK_SB AS5247 Eval Kit Socket Board
Buy our products or get free samples online at:
www.ams.com/ICdirect
Technical Support is available at: www.ams.com/Technical-
Support
Provide feedback about this document at: www.ams.com/Document-
Feedback
For further information and requests, e-mail us at:
ams_sales@ams.com
For sales offices, distributors and representatives, please visit:
www.ams.com/contact
Headquarters
ams AG
Tobelbaderstrasse 30
8141 Unterpremstaetten
Austria, Europe
Tel: +43 (0) 3136 500 0 Website: www.ams.com
Copyrights & Disclaimer
Copyright ams AG, Tobelbader Strasse 30, 8141 Unterpremstaetten, Austria-
Europe. Trademarks Registered. All rights reserved. The material herein may
not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner.
Demo Kits, Evaluation Kits and Reference Designs are provided to recipient on
an “as is” basis for demonstration and evaluation purposes only and are not
considered to be finished end-products intended and fit for general consumer
use, commercial applications and applications with special requirements such
as but not limited to medical equipment or automotive applications. Demo Kits,
Evaluation Kits and Reference Designs have not been tested for compliance with
electromagnetic compatibility (EMC) standards and directives, unless otherwise
specified. Demo Kits, Evaluation Kits and Reference Designs shall be used by
qualified personnel only.
ams AG reserves the right to change functionality and price of Demo Kits,
Evaluation Kits and Reference Designs at any time and without notice.
Any express or implied warranties, including, but not limited to the implied
warranties of merchantability and fitness for a particular purpose are
disclaimed. Any claims and demands and any direct, indirect, incidental,
special, exemplary or consequential damages arising from the inadequacy of the
provided Demo Kits, Evaluation Kits and Reference Designs or incurred losses
of any kind (e.g. loss of use, data or profits or business interruption
however caused) as a consequence of their use are excluded.
ams AG shall not be liable to recipient or any third party for any damages,
including but not limited to personal injury, property damage, loss of
profits, loss of use, interruption of business or indirect, special,
incidental or consequential damages, of any kind, in connection with or
arising out of the furnishing, performance or use of the technical data
herein. No obligation or liability to recipient or any third party shall arise
or flow out of ams AG rendering of technical or other services.
Revision Information
Changes from previous version to current revision 1-00 (2015-Aug-28)
Initial version 1-00
Note: Page numbers for the previous version may differ from page numbers
in the current revision.
Correction of typographical errors is not explicitly mentioned.
References