PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

IMPORTANT INSTALLATION INFORMATION

  • Installation should be carried out in accordance with the latest edition of the National wiring regulations. If in doubt please consult a qualified electrician.
  • Input voltage — 220V-240V 50Hz AC
  • AU-LP100C, AU-LP103C, AU-LP104C, AU-LP200C, AU-LP300C are not dimmable
  • AU-LP101C, AU-LP105C, AU-LP106C, AU-LP201C, AU-LP301C are dimmable
  • These luminaires are for indoor use only.
  • Ensure that ALL electrical connections are tight with no loose strands.
  • This product contains a light source of energy efficiency class E.

NOTE: For 1-10V dimming additional cabling is required to the switch position.
Icon This luminaire is not suitable for covering with insulation material.

INSTALLATION INSTRUCTIONS

Isolate the mains supply before servicing or installation

  1. Remove the selected ceiling panel and an adjacent panel to allow for installation of the LED Panel and LED Driver
  2. Connect the mains supply to the LED Driver supplied with the panel:
    • Brown (V+) — L (Live)
    • Blue (V-) — N (Neutral)
  3. Plug the lead from the driver into the LED panel plug
  4. Replace the adjacent ceiling panel
  5. Switch on the supply.
FOR 1-10V DIMMABLE VERSION
  1. Remove the selected ceiling panel and an adjacent panel to allow for installation of the LED Panel and LED Driver
  2. Connect the mains supply to the LED Driver supplied with the panel:
    • Brown (V+) — L (Live)
    • Blue (V-) — N (Neutral)
  3. Plug the lead from the driver into the LED panel plug
  4. Connect the White (+) and Black (-) from the connector block to the ‘+’ & ‘-‘ of the 1-10V switch wire. Note all 1-10V connections should be in parallel.
  5. Replace the adjacent ceiling panel 6. Switch on the supply.

Environmental Protection

(W.E.E.E.) — Aurora’s WEEE Reg.No. WEE/BG0130YX(UK Only)

 Waste Electrical & Electronic Equipment Regulations (WEEE) requires that any of our products showing this marking (left) must not be disposed of with other household or commercial waste. Aurora does not levy any WEEE disposal charges to its customers for affected WEEE related products. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Centre or retailer for recycling advice. If, when you purchased any Aurora product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his takeback of the product for the correct disposal.

WARRANTY

See www.auroralighting.com for full details of warranties and Extended Warranty Terms and Conditions. The warranty is invalid in the case of improper use, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National Wiring Regulations. Should this product fail during the warranty period it will be replaced free of charge, this is subject to correct installation and return of the faulty product. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.

Support

Website: www.auroralighting.com
Document version — AU P100C_101C_103C_104C_105C_106C200C_201C_300C_301C_V1_21_ENG&FRE.doc

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Aurora User Manuals

Related Manuals