B-TEK WorldWEIGH Portion WD Series Washdown Scale Instruction Manual

June 11, 2024
B-TEK

WorldWEIGH logo Instruction Manual

B-TEK WorldWEIGH Portion WD Series Washdown Scale

World WEIGH
Portion Washdown Scales
V1.06-1.10

PRECAUTIONS

CAUTION

  • Permit only qualified persons to service the instrument
  • Before connecting or disconnecting any components, unplug the power.
  • Failure to observe these precautions bodily harm or damage to or destruction of the equipment.
  • Avoid leaving the scale in direct sunlight, which may cause discoloration.
  • Avoid overloading, this could cause damage to the scale.
  • If the scale is not used for a long period of time, remove all batteries from the battery compartment to avoid leakage.
  • Avoid stacking materials on the scale when not in use.
  • Avoid unsuitable tables. The tables and floor must be rigid and isolated from vibration. Do not place near vibrating machinery.
  • Avoid unstable power sources. Do not use near high voltage machines such as welding equipment or large motors.
  • Do not mix battery brands. Replace all the batteries at the same time (Dry Cell).
  • Only use original World Weigh WD adaptor, others could cause damage to the scale.
  • When the scale is used with an adaptor it is not in conformance with IP-65 protection.

B-TEK WorldWEIGH Portion WD Series Washdown Scale -
fig

INTRODUCTION

  • The World Weigh WD series weighing scales are fully waterproof scales.
  • It is suitable for sanitary applications and general weighing.
  • IP65 waterproof technology
  • Stainless steel housing.
  • Super low power consumption.
  • Built in rechargeable battery.
  • Large 25mm (0.98inch) digits LCD with white LED back light display.
  • Optional 20mm (0.78inch) digits LCD rear display

SPECIFICATIONS

MODEL S29-6 S29-12 S29-30 S29-60
Capacity 6Ib / 3kg / 96oz 12Ib / 6kg / 192oz 30Ib / 12kg /480oz 60Ib /

25kg / 960oz
Readability| 0.0011b/0.005kg/ 0.02oz| 0.0021b/0.001 kg/0.05oz| 0.0051b/0.002kg / 0.1oz| 0.011b / 0.005kg / 0.2oz
Max. Divisions| 6000e
Weighing Units| kg/g/lb/oz/lb. Oz
Display| 0.98inch /25mm digits LCD Display with white LED back Light
Platter size| 9 x 7.5inch / 230 x 190mm
Housing| Stainless Steel
Operation Temperature| 14°F – 104°F / -10°C – + 40°C
Power| AC Adaptor 12V/500mA , Rechargeable Battery 6V/3.2Ah
Battery life| Approx.70 Hours LCD (no backlight)
Keypad| 3 mechanical keys
Dimensions
(inch/mm)| 9.6 (W) x 11.8 (D) x 5.0 (H) / 242.93 (W) x 299.7 (D) x 126.7 (H)
Gross weight| 9.31b (4.2kg)

DIMENSION(mm)

B-TEK WorldWEIGH Portion WD Series Washdown Scale - fig
2

INSTALLATION

Unpacking
Carefully take the balance out of its package, make it sure it’s not damaged, and all accessories are included.

  • Remove the Indicator from the carton.
  • Remove the protective covering. Store the packaging for use if you need to transport the scale later.
  • Inspect the scale for any damage.
  • Make sure all components are included.

Accessories,

  1. Balance
  2. Adaptor
  3. Pan
  4. Product manual

Level Adjusting
Place the scale on a table.

Check the water mark. If the bubble is not centered, adjust the leveling feet until reach center. Always check the level when you change the scales location.

Charging Battery

  • To charge the battery, insert the adaptor pin into the jack located under the scale. The adaptor simply plugs into the receptacle. The scale does not need to be turned on  to charge.
  • The battery should be charged for 12 hours to fully charge.
  • There is an LED on the left side of the display that shows the status of the battery charging. When the scale is plugged in, the battery will charge. If the LED is green,  the battery has a full charge. If it LED is red, the battery is nearly discharged and if yellow, the battery is being charged.
  • Do not use any power adaptor other than the one supplied with the scale.
  • Verify that the AC power socket outlet is properly protected.

Note: Please charge the battery before using the scale for the first time
CAUTION
Below the scale there is a breathable knob. Its default setting is for weighing. If you want to wash the scale tighten the knob, after washing release the knob for weighing.

|
---|---
When weighing, release screw for normal use.| When washing is needed, tighten the screw to seal the unit.

Installation

  • Place the scale on the table.

  • Connect the adaptor pin into the indicator adaptor jack.
    Adaptor jack is located on the underside of the scale.

  • Plug the adaptor into the receptacle. Equipment must be installed near an easily accessible outlet with a protective ground/ earth circuit.

  • Press the On/Off key. If you want to turn off, press the key again.

  • Display will show the version number and will start a self-check test.

  • After the self-check, the display will go to normal weighing mode.

  • A warm-up time of 15 minutes stabilizes the measured values.

  • Recommend using certified weights for calibration see details in parameter.
    The scale is now ready for use.

PARTS DESCRIPTION

B-TEK WorldWEIGH Portion WD Series Washdown Scale - fig
7

Key Board

B-TEK WorldWEIGH Portion WD Series Washdown Scale - Key
Board

Weight Display

Zero Zeroing Display
Stable Stable Display
Net Net Weight Display
Low Battery
kg/g/lb/oz/lb.oz Current Weighing Mode

Keys

| Turns the scale power On / Off
---|---
| Subtracts weight of container
| Sets display to Zero

OPERATION

Initial Start-up
Warm-up time of 15 minutes stabilizes the measured values after switching on.

  1. Power ON/OFF
    Switch on the scale by pressing . The display is switched on and the self test is started.
    If you want to switch off press the key again.

  2. Zero
    Pressing the key will ensure that the weighing starts at zero.

  3. Tare
    The weight of any container can be removed by pressing the button.
    • Load weight on the pan.
    • Press key. Zero is displayed, and tare is subtracted.
    • Remove the container from the platform and the tare weight is displayed. It will show a minus value.
    • Press key again and zero is displayed, tare weight is cleared.

  4. Back light
    Press the key for three seconds, the display will show “BK-AU”, Press the to select back light AU/OF/ON, then press the key to confirm.

Display Description
Bk AU Backlight will be turned on, when weight is applied or when display is

not at zero.
Bk oF| Backlight function will be turned off.
Bk on| Backlight will be always turned on.
5. Weighing Units
Press the and keys together to change the weighing mode. The weighing units can be changed to kg/g/lb/oz/lb. Oz

  1. Auto power off setting
    To change the auto power off setting to turn the scale off when not in use, scale will turn off after the setting time. Enter the setup menu by powering up and holding the  tare button then press tare until F5 off is displayed. Press zero to enter then.. press key to select the option, press key to confirm

PARAMETERS

Enter the Menu

  • Turn on the scale. Press during that start up until display will be shown
    Enter the Selected Menu

  • Press to confirm what is shown on the display.
    Select the Menu

  • Press to scroll through the menu block and zero to enter.

Note: If you want to access parameters F1 CAL ;F2 RES; F3 CAP;F6 GRA; , press the CAL switch in the battery compartment. Remove the battery housing and battery to locate the CAL switch.

B-TEK WorldWEIGH Portion WD Series Washdown Scale - Select the
Menu

Menu Description
F1 cal kg
lb Calibration in lb mode
F2 res 3000
--- ---

6000
dual
F3 cap| 3kg (6lb)| Set Scale Capacity
6kg (12lb)
12kg (30lb)
25kg (60lb)
F4 inp| Internal Counts
F5 0ff| Set scale for auto turn off.
3 min| Auto off after three minutes.
5 min| Auto off after five minutes.
15 min| Auto off after 15 minutes.
off| Auto off function disable
F6 grad| x.xx.xx| Set local gravity
F7 spd| 7 . 5| Set AD speed
15
3 0
6 0
Back| Back to weighing mode

CALIBRATION

  1. Turn on the scale. Press and hold key during start up until display shows. F1 Cal Then press the calibration switch located below the battery

  2. Press to confirm, the display will show kg
    a. If calibrating in kg, continue step 3
    b. If calibrating in lb, press the  key and lb will be shown on the display
    Ensure that the platter is empty.
    Note: Press the key to choose either “kg” or “lb”.

  3. Press the to confirm and the display will show unload

  4. Press the display will show the current calibration weight value. 2 lb

  5. If needed press to select the weight value.

  6. Apply the weight to the platform. Wait for the indictor to stabilize then press the  key to confirm. The display will show PASS.

  7. The scale will restart.
    If the display shows an error message or incorrect measurement, repeat the calibration again.

ERROR CODES

Error Message Description Solution
Err 4 Zero setting error Zero setting range exceeded due to switching

on.(4%max)
Make sure platform is empty.
Err 5| Key board error| Check the keys and connecter.
Err 6| A/D value out of range| Make sure platform is empty and insure that the pan is installed proper. Check the load cell connectors.
Err 9| Unstable Reading| Check for any air variation, vibration, RF noise or if the scale is touching anything.
Check the load cell and connecters.
Err 17| Tare out of range| Remove the load and restart scale again.
–owl–| Over range| Remove the load. Re calibrate
Fail / fail| Calibration Error| Re calibrate
Ba lo / lobe| Battery low| Re charge battery, check the voltages.

DRAWINGS

B-TEK WorldWEIGH Portion WD Series Washdown Scale -
DRAWINGS

REPLACEMENT PART NUMBERS

Parts List

No B-TEK Part # Parts Name
1 899-300139 SS TOP PAN Part number 1
3 899-300140 Rubber1
4 899-300141 Rubber2
5 899-300142 Pan Support
14 899-300143 Front Display PCB
16 899-300170 WD-6lb     Load Cell
16 899-300171 WD-12lb   Load Cell
16 899-300172 WD-30lb   Load Cell
22 899-300176 Battery
23 899-300145 Battery Box Cover
32 899-300173 WD-6LB OVERLAY
32 899-300174 WD-12LB OVERLAY
32 899-300175 WD-30LB OVERLAY
33 899-300147 Front Display Protection
43 899-300148 Seal Rubber 2
46 899-300149 Foot Fixer
47 899-300150 Foot

B-TEK Scales, LLC
1510 Metric Ave. S.W.
Canton, OH 44706
Tel: 330.471.8900
Fax: 330.471.8909
www.B-TEK.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals