B-TEK HRB High Resolution Base Setup Instruction Manual

June 12, 2024
B-TEK

B-TEK HRB High Resolution Base Setup

B-TEK HRB High Resolution Base Setup

CONFIGURATION

Under System Configuration: Change active scales to 2.
Configuration

Under Scale Configuration: Ensure mode is HRB and the #2 scale settings are correct.
Configuration

Serial Port Configuration: Should show serial port 1 is disabled for the HRB base as shown in the image below.
Configuration

Wiring the HRB scale base.

Wiring

WARNING: The scale connection is an RS232 port only, Do not plug the base into an Ethernet port as this may damage file Ethernet hub.

Note: The scale base is powered by the indicator RS232 port.

The HRB scale base must be linked to a T405 or T419 indicator only. It utilizes one of the indicators dedicated RS-232 ports to correctly communicate with the base. If multiple HRB scale bases are implemented, each must use its own RS-232 port.

(B-TEK Part# 825-300032) RS232 Base to indicator cable (keyed RJ45 to pig tailed end) 10ft.

(B-TEK Part# 825-300033) RS232 Base to indicator cable (keyed RJ45 to pig tailed end) 25ft.

(B-TEK Part# 825-300034) RS232 Base to indicator cable (keyed RJ45 to pig tailed end) 50ft.

These cables have the correct keyed RJ45 connector. Pictured below are the cable ends for the connection to the HRB and T series indicator.
Wiring

The table indicates connections to TB3 for Serial Port 1. If using Serial Port 2, then use pin TB3-3 for RX_Base and pin TB3-5 for TX_BASE.
Wiring

RJ45 Connector Color Termination function
Pin 1 WHITE/ORANGE TB3-1 GROUND
Pin 8 BROWN TB3-1 GROUND
Pin 6 GREEN TB3-2 RX – BASE
Pin 3 WHITE/GREEN TB3-4 TX- BASE
Pin 7 WHITE/BROWN TB3-6 +-5V
Pin 5 WHITE/BLUE TB3-6 +-5V