Megger EVCC300 Electric Vehicle Charger Checker User Guide

June 9, 2024
Megger

EVCC300 Electric Vehicle Charger Checker
User GuideMegger EVCC300 Electric Vehicle Charger
Checker 5 Commonwealth Ave
Woburn, MA 01801
Phone 781-665-1400
Toll Free 1-800-517-8431

► Visit us at www.TestEquipmentDepot.com

EVCC300 Electric Vehicle Charger Checker

Register your Product
To get these benefits:
Megger EVCC300 Electric Vehicle Charger Checker - icon
1

Megger EVCC300 Electric Vehicle Charger Checker - fig
1

Safety warnings

These safety warnings must be read and understood during use. THE EQUIPMENT MUST BE USED ONLY B National Health and Safety Legislation requires users risk assessment of all work so as to identify potential before the instrument is used. They must be observed Y SUITABLY TRAINED AND COMPETENT PERSONS. of this equipment or their employer to carry out valid sources of danger and to mitigate risk.

  • If this equipment is modified or used in a manner other than specified by the manufacturer, the protection provided by the equipment may be impaired.
  • This equipment is not intrinsically safe and must not be used in hazardous atmospheres.
  • This equipment is for indoor and outdoor use up to 2,000m altitude. It must not be used in wet conditions or outside the specified temperature range.
  • Use only the adapters provided with the instrument.
  • If the equipment gets wet, turn off and disconnect, and wait for it to dry before turning back on. Clean equipment with a dry, clean cloth.
  • Inspect the equipment for damage before each use. The equipment must not be used if any part of it is damaged.
  • The touch-pad test must not be relied on to check protective earth integrity. It is an ‘open-circuit’ test and will not indicate a high impedance earth connection.
  • The live phase indicators are an additional safety feature which may fail. Use independent means to verify whether circuits are energised. Safe working practice must be observed.
  • The PE (protective earth) pre-test must be carried out before any other test.
  • If the PE pre-test fail, there may be high voltage present within the charging station and on the output terminals and a risk of electric shock. Other tests must not be started until the fault is investigated and rectified.
  • If no voltage is present between the L & N of the terminals or between the L & N of the test connector when the instrument is connected to the charging point in charging mode, this may be because the instrument’s internal fuse has blown.
  • Disconnect from all other equipment before opening the fuse or battery compartments.
  • Replacement fuses must be of the correct type and rating. Failure to fit the correctly rated fuse may result in a safety hazard and may cause damage to the instrument in the event of an overload.
  • Use only non-rechargeable cells as specified in the instructions.
  • Replacement cells must be of the type specified in the instructions. Observe the correct polarity
  • No user serviceable parts are inside the equipment. Refer repairs to Megger approved service centres.
  • At the end of the equipment’s life dispose of it according to local regulations for recycling. Do not dispose of this equipment to landfill, sewage systems or by fire.

Refer to user instructions

Test lead safety warnings: Test leads, including crocodile clips, must be in good condition, clean, dry and free of broken or cracked insulation. The lead set or its components must not be used if any part of it is damaged. Overload categories for mains connections are rated as follows:
CAT IV – Measurement category IV: Equipment connected between the origin of the low-voltage mains supply and the distribution panel.
CAT III – Measurement category III: Equipment connected between the distribution panel and the electrical outlets.
CAT II – Measurement category II: Equipment connected between the electrical outlets and the user’s equipment.
Measurement equipment may be safely connected only to circuits at the marked rating or lower.

Safety symbols marked on the instrument

| HIGH VOLTAGE. Risk of electric shock
---|---
| DOUBLE INSULATED. This instrument has double or reinforced insulation throughout.
Icon| Equipment complies with current EU directives
| Equipment complies with current UK legislation
| N13117 Equipment complies with current “C tick” requirements
****| Do not dispose of to landfill, sewage systems or by fire

Certificate of test
Product MNININIM Serial Number xxxxxxxxxx
This Certificate of Test shows that this instrument has been fully tested by the manufacture; it fully conformed to its published specifications.
The test equipment used for this purpose is regularly calibrated against company standards that are traceable to National or International Standards.
The Quality Systems of Megger Instruments Ltd have been assessed and registered by 1351 to BS EN ISO 9001 fENIS090011 under the Certificate of Registration number B51009250.
Registered to ISO 9001 Certificate No. 09250. Certificate No. EMS61597

Test Equipment Depot
– 800.517.8431
– 5 Commonwealth Ave, MA 01801
TestEquipmentDepot.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals