CONDTROL Fliesen 4D Laser Level User Manual

June 9, 2024
CONDTROL

condtrol-logo

Fliesen 4D Laser Level

CONDTROL-Fliesen-4D-Laser-level-product-image

Product Information: Fliesen 4D Laser Level

The Fliesen 4D Laser Level is a high-quality laser level that is designed to provide accurate and reliable measurements for a range of applications. The laser level is designed with safety in mind and includes a range of features to help ensure safe and effective use.

The laser level is suitable for use in a range of applications, including tiling, carpentry, and other construction projects. It is designed to provide accurate measurements and can be used to create precise lines and angles for a range of tasks.

The Fliesen 4D Laser Level is easy to use and comes with a comprehensive user manual that provides detailed instructions on how to use the device effectively. The user manual should be read carefully before using the device for the first time to ensure safe and effective use.

Safety Regulations

It is important to follow the safety regulations outlined in the user manual when using the Fliesen 4D Laser Level. Failure to do so could result in serious injury or harm. Some of the key safety regulations include:

  • Read the user manual carefully before using the device for the first time.
  • Do not misuse the device.
  • Do not remove warning signs and protect them from abrasion.
  • Do not stare into the beam of the laser.

Product Usage Instructions

To use the Fliesen 4D Laser Level, follow these simple steps:

  1. Read the user manual carefully before using the device for the first time.
  2. Ensure that the device is fully charged or has fresh batteries installed.
  3. Select the appropriate mode for your application.
  4. Position the device on a stable surface or mount it securely to a tripod.
  5. Turn on the device and adjust the laser to the desired position.
  6. Use the laser to create precise lines and angles for your application.
  7. When you are finished, turn off the device and store it in a safe place.

By following these simple steps, you can use the Fliesen 4D Laser Level to achieve accurate and reliable measurements for a range of applications.

PRODUCT SAFETY REGULATIONS

The user manual should be read carefully before you use the device for the first time. Unintended use of the device can be dangerous for human’s health and cause serious injury. Keep this user manual. If the device is given to somebody for temporary use, be sure to enclose user manual to it.

  • Do not misuse the device.
  • Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the device.

Laser radiation!
Do not stare into beam Class 2 laser
<1 mW 515 nm
IEC 60825-1: 2007-03

  • Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
  • To protect your eyes close them or look aside.
  • Always install the product in such a way, so that the laser line is below or above the eye level.
  • Do not let unauthorized people enter the zone of product operation.
  • Store the product beyond reach of children and unauthorized  people.
  • It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
  • Do not use the product in explosive environment, close to flammable materials.
  • Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult healthcare practitioner.

PRODUCT DESCRIPTION
Laser level Fliesen 4D CONDTROL is designed for projecting and controlling of vertical and horizontal planes and lines. The laser level has 2 operating modes:

  • automatic leveling, which allows to automatically compensate irregularities within self-leveling range up to 3°.
  • locked compensator, to project inclined planes and lines; Pulse mode allows to increase working range of the laser level by using the laser receiver or to work when laser is hard to define in bright lighting conditions.
    The laser level is suitable for use at both indoor and outdoor building areas.
  1. Laser beam exit windows
  2. Control panel
  3. Switch bar
  4. Battery
  5. Battery release button
  6. Battery charge indicators
  7.  Type-C charging port
  8. Tripod thread 1/4’’
  9. Tripod thread 5/8’’

CONDTROL-Fliesen-4D-Laser-level-01

Control panel CONDTROL-Fliesen-4D-Laser-level-02

  1. Switch on/off the laser lines
  2. Switch on/off the pulse mode

TECHNICAL SPECIFICATIONS

Working range / with receiver* 30/60 m
Accuracy ±0.3 mm/m
Self-leveling range ± 3°
Distance between horizontal laser line and floor 18 mm

Continuous working time

  • with one laser emitter switched  on
  • with all laser emitters switched  on

| 20 hours

5 hours

Operating temperature| -10°C … +40°C
Storage temperature| -15°C … +50°C
Relative humidity| 90%
Dust and water protection rate| IP54
Tripod thread| 1/4’’ and 5/8’’
Laser| Class II 515 nm

< 1 mW

Battery| 3.7V 4000 mAh

Li-Ion rechargeable

Dimensions| 147х91х147 mm
Weight| 878 g

  • The working range may differ from the declared depending on the lighting conditions.

DELIVERY PACKAGE

  • Laser level – 1 pc.
  • Battery (3.7V 4000 mAh Li-Ion) – 2 pcs.
  • Wall mount – 1 pc.
  • Clamp – 1 pc.
  • Lifting platform – 1 pc.
  • Magnetic target – 1 pc.
  • Charger – 1 pc.
  • User manual – 1 pc.
  • Plastic case – 1 pc.

BEFORE START OPERATION

Power supply
The laser level is powered by 3.7V 4000 mAh Li-Ion rechargeable battery included in the delivery package.

Install/charge the Li-ion battery
Install the battery in the battery compartment.
Use only the battery included in the delivery package.
If a power indicator on the left is flashing blue, charge the battery.

The battery should be charged in the following way:

  1. Remove the battery from the device.
  2. Use charger, included in the delivery package, to connect the battery to external power source. The power indicators on the battery will be flashing blue while charging.
  3. The battery charging time is about 3 hours.
  4. As soon as the charging time runs out, the power indicators will stop flashing. Disconnect the charger and put the battery in the battery compartment.
    It is allowed to charge the battery installed in the battery compartment.

OPERATION
Install the device on a firm and stable surface, lifting platform or tripod. Move the switch bar to select the required operation mode.

  1. Automatic leveling
    Move the switch bar to position ON.
    The laser level will switch on.
    Lower H-line is on.
    Short press to switch on the required laser lines.
    Short press to switch on/off the pulse mode.
    Move the switch bar to position OFF to switch off the laser level.

  2. Projection of inclined planes
    Move the switch bar to position OFF.
    Press and hold during 3 seconds. Lower H-line is on.
    Laser line is flashing every 5 seconds.
    Short press to switch on the required laser lines.

  3. After all combinations of lines are switched on, the next short press will switch off the laser level.
    Press to switch on/off the pulse mode.

Note: To increase the operating time and avoid the risk of unintentional blinding switch on the laser only before start operation.
If operated near objects or airflows different from the environment temperature the laser line may tremble due to heterogeneity of the atmosphere. The longer the distance, the more trembling can be observed.
The width of the laser line increases with the increasing of the operating distance. The marking should be made along the axis of the laser line. For maximum accuracy, use the middle portion of the laser line.
It should be noted that the shape of the laser line on the object’s surface (e.g. walls, ceilings) depends on the curvature and slope of the surface relative to the laser plane.

ACCURACY CHECK
Horizontal line
Accuracy check of horizontal line is carried out by 2 walls located opposite each other at a 5m distance.

  1. Put the laser level to one of the walls as close as possible (Figure A). Move the switch bar to position ON and switch on both vertical and horizontal planes. Rotate the laser level so that laser emitters are located opposite to the near wall and laser lines cross each other. Mark location of laser lines crossing as А1. Mark location of laser lines crossing on another wall as B1.CONDTROL-Fliesen-4D-Laser-level-05
  2. Rotate the laser level by 90°, measure deviation of a laser line from point В1 (Figure B). If deviation exceeds 1.5 mm – please contact the service center. CONDTROL-Fliesen-4D-Laser-level-06
  3. Repeat actions described in point 2 twice, rotating the laser level in one direction.
  4. Install the laser level closer to the opposite wall. Mark location of laser lines crossing as В2 (points В1, В2 must be located at the same vertical) (Figure C). CONDTROL-Fliesen-4D-Laser-level-07
  5. Rotate the laser level by 180°and mark location of laser lines crossing on the opposite wall as A2 (points A1, A2 must be located at the same vertical) (Figure D).
  6. Measure distances dA, dB between points А1, А2 and В1, В2 accordingly (Figure D). If difference between values dA, dB exceeds 3 mm – please contact the service center.

CONDTROL-Fliesen-4D-Laser-level-08Attention: please do accuracy check for each horizontal plane separately.

Vertical line
Use a plumb bob as a reference of a vertical line. Put the laser level at 1.5m distance from the plumb bob. (Fig. E).

  1. Move the switch bar on position ON, and align vertical laser line with the low point of plumb bob.
  2. If deviation between the laser line and the plumb line exceeds 0.3 mm per 1m of plumb bob length (for a 2.5m plumb bob deviation shouldn’t exceed 0.7 mm) – please contact the service center. CONDTROL-Fliesen-4D-Laser-level-09

CARE AND MAINTENANCE

Attention! This laser level is a precise optic-mechanical device and requires careful handling. Before starting work, as well as after mechanical influences (falling, bumps), check the accuracy of the device.

Observation of the following recommendations will extend the life of the device:

  • Store the device, spare parts and accessories away from children and unauthorized people.

  • Transport the device with locked compensator only.

  • Protect the device from bumps, falls, and excessive vibration; do not let moisture, construction dust and foreign objects get inside the device.

  • In case moisture gets inside the device, first of all, remove the batteries and then contact the service center.

  • Do not store or use the device for a long time in high humidity conditions.

  • Check the accuracy of the device occasionally (check the paragraph «Accuracy check»).

  • Clean the device with a soft wet cloth. Do not use harsh chemicals, cleaning solvents or cleaning agents.

  • Wipe the laser aperture with a soft lint-free cloth and isopropyl alcohol.

  • Remove the Li-ion battery or alkaline batteries from the device before connecting the charger, otherwise the device may fail.
    Failure to observe the following rules may lead to electrolyte leakage from the batteries and failure of the device:

  • Remove the battery from the device, if it’s not used for a long time.

  • Do not leave discharged battery in the device.

  • Avoid heating the battery to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult the doctor.

UTILIZATION
Expired tools, accessories and package should be passed for waste recycle. Please send the product to the following address for proper recycle:

CONDTROL GmbH
Im Wiegenfeld 4 85570 Markt Schwaben Germany

Do not throw the product in municipal waste!
According to European directive 2002/96/ЕC expired measuring tools and their components must be collected separately and submitted to environmentally friendly recycle of wastes.

WARRANTY

All CONDTROL GmbH products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation do not expire.

  1. CONDTROL GmbH agrees to eliminate all defects in the product, discovered while warranty period, that represent the defect in material or workmanship in full volume and at its own expense.
  2. The warranty period is 24 months and starts from the date  of purchase by end consumer (see the original supporting document).
  3. The Warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, the use of non-original accessories and spare parts. Modifications in design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal operation of the product.
  4. CONDTROL GmbH reserves the right to decide on replacement or repair of the device.
  5. Other claims not mentioned above, are not covered by the warranty.
  6. After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
  7. CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, rental cost of alternative equipment for the period of repair.
    This warranty applies to German law except provision of the United Nations Convention on contracts for the international sale of goods (CISG).