Lafayette Instrument ACU100 Range of Motion Inclinometer Instruction Manual

June 9, 2024
Lafayette Instrument

Lafayette Instrument logo ACU100 Range of Motion Inclinometer
Instruction ManualLafayette Instrument ACU100 Range of Motion
Inclinometer

Model ACU100

Features

  • Designed for high inter and intra instrument reproducibility
  • Range of motion in three axis: left to right (L/R), front to back (F/B), and rotation (ROT)
  • Data storage for up to 250 tests in on-board memory
  • Storage of data on button press
  • Measurement range 0-360 degrees
  • Tone to indicate start and stop
  • Microprocessor controlled
  • Built-in stored data browsing capability
  • Easy to read graphical LCD display
  • Automatic shut off after 5 minutes of inactivity
  • Battery indicator on LCD display
  • Interactive menus allowing users to select device options
  • Battery powered: (1) rechargeable lithium-ion battery

Specifications

  • Size: 4.61” x 3.27” x 0.97” (11.7cm x 8.3cm x 2.46cm)
  • Weight: 121.4 g
  • Range: 0-360 degrees
  • Accuracy: ± 1 % over full range in vertical axis, ± 2 % over full range in horizontal axis
  • Resolution: 0.1 degrees
  • Battery Life: 10 hrs powered on, 30 minutes after low battery condition
  • Battery Capacity: 900 – 1200 mAh Lithium Ion Rechargeable Battery
  • Charge Time: 80% charge => 1 hour / Full charge => 3 hours
  • Data Storage Capacity: 250 tests
  • 50 ms sample rate

Precautions

  • Upon initial receipt of ROMI, charge device for a minimum of 2 hours.
  • When performing repeated tests, inconsistent placement of the ROMI will adversely affect scores.
  • Extreme temperature, especially heat, may affect the values obtained.
  • Large magnetic fields could affect the calibration or readings
  • Care should be taken not to drop the ROMI.
  • The plane of motion should be consistent and relative to the device
  • This device uses a Lithium-Ion battery as a power source. It is recommended that the battery be charged at least once every six months. Failure to periodically charge the  battery may result in battery damage or device malfunction.

Charging

The low battery indicator screen is shown when the battery needs to be charged. The screen will be displayed and then the system will power off. This screen will be displayed when the power button is pressed until the unit is recharged via the USB-C connector. The device should take about one (1) hour to charge 80% of the capacity, or  about three (3) hours for a full charge.

Function Buttons

The ROMI has five function buttons that control the menus and allow the selection of options and settings.

  1. POWER/MENU/SELECT Button: The Round MENU/SELECT button is located on the bottom middle of the ROMI. This is the button used to power on the  device. Holding the MENU/SELECT button for 5 seconds will power off the unit. It is placed for easy access regardless of right or left hand operation. The  MENU/SELECT allows you to enter into the Menu screen and select various options within it.

2, 3. NAVIGATION Buttons: : While on the Test screen the NAVIGATION buttons are used to undo a trial or delete a test. While in the Menu screen, the  NAVIGATION buttons are used to navigate the various menu screens.
4, 5. BASE buttons: On the Test screen the BASE buttons are used to START/STOP tests and SAVE results when applicable. On the menu screen these buttons are used  to return back one screen, BACK, or return to the Test screen, TEST. These buttons can be flipped for a specific dexterity by changing the button orientation in the OPTIONS menu.

Screens Test Screen

The Main Measurement Screen shows all measurement information that is being captured. This screen is shown whenever a measurement is in progress.

  1. Battery Indicator: Indicates the remaining capacity in the charge of the battery.

  2. Angle Display: Displays the current angle read during a test or the last trial while not testing.

  3. Wireless Communication Indicator: This character indicates when the wireless is enabled.

  4. Time Display: This time is displayed and can be set manually or synced with a PC in the Options Menu.

  5. Sound Indicator: Indicates whether beeper is on or off for the current test.

  6. Test Number: Displays the test number while a test is being displayed.

  7. Axis of Rotation: Displays the axis of the current test relative to the device.
    • ROT: Rotation around the device
    • F/B: Front to back orientation
    • L/R: Left to right orientation

  8. *SAVE: In this example, represents the label for the right BASE button. Save will save the current test.

  9. *DELETE: In this example, represents the label for the UP arrow button. Delete will remove all current trials without saving.

  10. *UNDO: In this example, represents the label for the DOWN arrow button. Undo will remove the last trial without saving.

  11. *START/STOP: In this example, represents the label for the left BASE button. Start will start a new trial. Stop will stop the current trial and add it to the trial list.

  12. Trial List: This window displays the trial number and the angle the trial was ended on.

Lafayette Instrument ACU100 Range of Motion Inclinometer - BASE
buttons1

  • Indicates button mapping for option will change depending on chosen button orientation – set in OPTIONS menu

Dual Setup Menu Screen
The Dual Setup menu allows users to connect two (2) devices together for dual inclinometer. Once selected from the main menu, the device will scan for other devices  nearby. This could take 20-30 seconds. Once the scan is finished, all found devices are displayed on the screen. Use the navigation buttons to select the device to connect.

Once the main device connects to the companion unit, the screen on the companion will display “Connected To Peer Device”.
Once connected, navigate back the test menu on the main device and run normal tests now using both the main and companion units. The main device dictates the  orientation of the trial. When beginning a test, the main device and companion unit should start in the same orientation and plane. The main device will automatically  calculate the combined angle and display it on the screenLafayette Instrument ACU100 Range of Motion Inclinometer - Dual
Setup1

To disconnect the devices, select the Dual Setup icon in the main menu. Once the devices are disconnected from each other, they can be used individually for single inclinometer.

Saved Data Menu Screen
The Saved Data menu allows users to manage tests that have been saved in the internal memory.Lafayette Instrument ACU100 Range of Motion Inclinometer -
Menu Screen

Options Menu Screen
The Options menu allows user to customize the setup of their unit.

  • WIRELESS: Toggles on/off the module for wireless connection.
  • BACKLIGHT: Toggles unit’s backlight on/off.
  • SOUND: Toggles unit’s sound on/off.
  • BUTTON ORIENTATION: Switches the functionality of the base buttons, allowing for use in either hand.
  • LOCK ANGLE: Changes the angle that locks the device in its axis.
  • DATE: Updates the ROMI system date.
  • TIME: Updates the ROMI system time.

Information Menu Screen
The Information menu provides a contact email and various information about the ROMI.
Sensor Calibration
The sensor performs self-calibration, but the device also monitors the current calibration status both when the test window opens and at the beginning  of a trial. The calibration window is displayed when the calibration status shows it is not fully calibrated. The window displays three letters for each sensor followed by the number  representing the calibration status (0-3) as shown here:

Accelerometer (A)
If this sensor needs calibration, place the device in 6 different stable positions for a period of few seconds to allow the accelerometer to calibrate. Make sure that there is slow  movement between 2 stable positions. The 6 stable positions could be in any direction, but make sure that the device is lying at least once perpendicular to the x, y, and z axis.
Gyroscope (G)
If this sensor needs calibration, place the device in a single stable position for a period of few seconds to allow the gyroscope to calibrate.
Magnetometer (M)
If this sensor needs calibration, make random movements (for example: writing the number ‘8’ in air) until sensor is fully calibrated.

Calibration Values
0: Sensor is not calibrated
1: Sensor is partially calibrated
2: Sensor is partially calibrated
3: Sensor is fully calibrated

Sample Exercises

Sample: Storing Multiple Data Readings

  1. Hold inclinometer in natural, neutral position
  2. Flex your hand. When maximum flex has been reach press the left base button.
  3. Repeat steps 1-2 to store up to six measurement readings.
  4. The Saved Data can be viewed by pressing the POWER/MENU/SELECT button

Sample: Cervical Lateral Bending – Single Inclinometer
Prepare Inclinometer

  1. Power on device by pressing the POWER/MENU/SELECT button.
  2. Position individual’s head in a neutral position.
  3. Place device over calvarium.

Take Measurements

  1.  Press the left base button* to begin the test.
  2. Ask individual to bend their head to the left.
  3.  When individual reaches maximum range of motion, press the left base button* to store the maximum left cervical later bending angle.
  4.  Ask individual to return to neutral position.
  5. Repeat measurement steps 2-4 three to six times to achieve validity criteria of +/- 5 degrees or 10%.
  6. Follow steps 1-4 to measure right cervical lateral bending.

Sample: View Data

  1. To recall stored data, press the POWER/MENU/SELECT button to display the Settings menu.
  2. Press the UP arrow button to highlight the Saved Data icon and press the POWER/MENU/SELECT button again to display the stored data options, then press  POWER/MENU/SELECT to choose OPEN SAVED TESTS.
  3. Saved Data can be navigated using the UP and DOWN arrow buttons. Pressing POWER/MENU/SELECT will display the highlighted Saved Data.
  • Indicates button mapping for action will change depending on chosen button orientation – set in OPTIONS menu

Resets
To restore to factory defaults, press MENU/SELECT and navigate to the Information screen. Press and hold MENU/SELECT then press the left base button consecutively  until screen reads “Factory reset will delete all tests and all settings”. Follow the prompts on screen until the screen reads “Factory reset complete!”.
Hard Reset: If the inclinometer freezes press down arrow and the up arrow until the unit powers off and back on.

Firmware Updates

Lafayette Instrument periodically updates the firmware for select products. Visit our website to download our Firmware Updater software. The ROMI can be updated by  plugging in the USB charger into your computer and downloading the current version of the firmware via the Firmware Updater.

Inclinometer Cleaning

Hard surfaces can be cleaned with a bleach-free sanitizing wipe. Alcohol wipes may also be used.
Cloth or foam surfaces can be cleaned with anti-bacterial soap and water and allowed to air dry. Care must be taken to not allow water to penetrate the enclosure as damage to the circuit may occur.
Disclaimer: These cleaning instructions for Lafayette Instrument products are a recommendation of compatible cleaning materials only. Product end users are responsible  for instituting an appropriate cleaning regimen utilizing best practices and techniques. Lafayette Instrument assumes no responsibility for the cleanliness or sanitation of the products after initial use nor makes any claim that the use of the recommended cleaning materials mitigates all risk of potential cross infection.

FCC Compliance Statement

Contains FCC ID: A8TBM78ABCDEFGH
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including  interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and  used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a  particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The FCC ID for the ROMI is available via the device menu by selecting MENU > INFORMATION.

Symbol Glossary

The following glossary describes the symbols included on the device label. Some symbols may not apply to this device.

| Manufacturer
Indicates the medical device manufacturer
ISO 15223-1:2016 Ref. 5.1.1| | Authorized Representative
Indicates authorized representative in the EU
ISO 15223-1:2016 Ref. 5.1.2
---|---|---|---
| Date of Manufacture
Indicates date when device was manufactured
ISO 15223-1:2016 Ref. 5.1.3| | Use by Date
Indicates date after which the device is not to be used
ISO 15223-1:2016 Ref. 5.1.4
| Batch Code
Identifies the manufacturer’s lot or batch code
ISO 15223-1:2016 Ref. 5.1.5| | Catalog Number
Indicates the manufacturer’s part number
ISO 15223-1:2016 Ref. 5.1.6
| Serial Number
Identifies the manufacturer’s serial number
ISO 15223-1:2016 Ref. 5.1.7| | Serial Number
Identifies the manufacturer’s serial number
ISO 15223-1:2016 Ref. 5.1.7
| Do not use if package is damaged
Indicates device should not be used if opened
ISO 15223-1:2016 Ref. 5.2.8| | Do not use if package is damaged
Indicates device should not be used if opened
ISO 15223-1:2016 Ref. 5.2.8
| Fragile, handle with care
Indicates device that needs careful handling
ISO 15223-1:2016 Ref. 5.3.1| | Keep away from sunlight
Indicates a device needs protection from sunlight
ISO 15223-1:2016 Ref. 5.3.2
| Temperature limit
Indicates upper and lower temperature limits
ISO 15223-1:2016 Ref. 5.3.7| | Keep dry
Indicates device should be protected from moisture
ISO 15223-1:2016 Ref. 5.3.4
| Do not reuse
Indicates a single use device
ISO 15223-1:2016 Ref. 5.4.2| | Consult Instructions for use
Prompts the user to consult the user manual
ISO 15223-1:2016 Ref. 5.4.3
| Contains latex
Indicates the presence of natural rubber latex
ISO 15223-1:2016 Ref. 5.4.5| | Caution
Indicates the need to review cautionary information
ISO 15223-1:2016 Ref. 5.4.4
| Humidity Limitation
Indicates the upper and lower limits of humidity
ISO 15223-1:2016 Ref. 5.3.8| | CE Mark
Product is certified for sale in the EU
Regulation (EC) No. 765/2008 Annex II
| Humidity Limitation
Indicates the upper and lower limits of humidity
ISO 15223-1:2016 Ref. 5.3.8| | Medical Device
Enclosed equipment is classified as a medical device
No Standard Applicable

Terms and Conditions

LIC Worldwide Headquarters
Toll-Free: 800-428-7545 (USA only)
Phone: 765-423-1505
Fax: 765-423-4111
Email: sales@lafayetteinstrument.com
export@lafayetteinstrument.com (Outside the USA)
Mailing Address:
Lafayette Instrument Company
PO Box 5729
Lafayette, IN 47903, USA
Lafayette Instrument Europe:
Phone: +44 1509 817700
Fax: +44 1509 817701
Email: eusales@lafayetteinstrument.com

Phone, Fax, Email or Mail-in Orders
All orders need to be accompanied by a hard copy of your purchase order.
All orders must include the following information:

  • Quantity
  • Part Number
  • Description
  • Your purchase order number or method of pre-payment
  • Your tax status (include tax-exempt numbers)
  • Shipping address for this order
  • Billing address for the invoice we’ll mail when this order is shipped
  • Signature and typed name of person authorized to order these products
  • Your telephone number
  • Your email address
  • Your FAX number

Domestic Terms
There is a $50 minimum order. Open accounts can be extended to most recognized businesses. Net amount due 30 days from the date of shipment unless otherwise specified  by us. Enclose payment with the order; charge with VISA, MasterCard, American Express, or pay COD. We must have a hard copy of your purchase order by mail,  E-mail or fax. Students, individuals and private companies may call for a credit application.
International Payment Information
There is a $50 minimum order. Payment must be made in advance by: draft drawn on a major US bank; wire transfers to our account; charge with VISA, MasterCard,  American Express, or confirmed irrevocable letter of credit. Proforma invoices will be provided upon request.
Exports
If ordering instrumentation for use outside the USA, please specify the country of ultimate destination, as well as the power requirements (110V/60Hz or 220V/50Hz). Some model numbers for 220V/50Hz will have a “*C” suffix.
Quotations
Quotations are supplied upon request. Written quotations will include the price of goods, cost of shipping and handling, if requested, and estimated delivery time frame.  Quotations are good for 30 days, unless otherwise noted. Following that time, prices are subject to change and will be requoted at your request.
Cancellations
Orders for custom products, custom assemblies or instruments built to customer specifications will be subject to a cancellation penalty of 100%. Payment for up to 100% of  the invoice value of custom products may be required in advance. Cancellation for a standard Lafayette Instrument manufactured product once the product has been shipped  will normally be assessed a charge of 25% of the invoice value, plus shipping charges. Resell items, like custom products, will be subject to a cancellation penalty of 100%.
Exchanges and Refunds
Please see the cancellation penalty as described above. No item may be returned without prior authorization of Lafayette Instrument Company and a completed Return Form.  A copy of the Return Form or your assigned Return # (you will receive this via email after submitting the form) must be included with the returned goods. The  merchandise should be packed well and fully insured. Unopened merchandise may be returned prepaid within thirty (30) days after receipt of the item and in the original  shipping carton. Collect shipments will not be accepted. Returned products must be in saleable condition, and credit is subject to inspection of the merchandise.
Repairs
Instrumentation may not be returned without prior authorization by Lafayette Instrument Company and a completed Return Form. When you complete the Form, or call  Lafayette Instrument, you will receive a Return #. Your Return # number will be good for 30 days. Address the shipment to: info@lafayetteinstrument.com
Lafayette Instrument Company
3700 Sagamore Parkway North
Lafayette, IN 47904, USA.
Shipments cannot be received at the LIC PO Box. Items should be packed well, insured for full value, and returned along with a copy of the Return Form or the Return #.  An estimate of repair will be given prior to completion ONLY if requested in an enclosed cover letter. We must have a completed purchase order by mail or fax, or repair  work cannot commence for non warranty repairs.

Damaged Goods
Damaged instrumentation should not be returned to Lafayette Instrument prior to a thorough inspection. If a shipment arrives damaged, note damage on delivery bill and  have the driver sign it to acknowledge the damage. Contact the delivery service, and they will file an insurance claim. If damage is not detected at the time of delivery, contact  the carrier/shipper and request an inspection within 10 days of the original delivery. Please call the Lafayette Instrument Customer Service Department for repair or  replacement of the damaged merchandise.
Limited Warranty
Lafayette Instrument Company warrants equipment manufactured by the company to be free of defects in material and workmanship for a period of one year from the date  of shipment, except as provided hereinafter. The original manufacturer’s warranty will be honored by Lafayette Instrument   for items not manufactured by Lafayette Instrument Company, i.e. resell items. This assumes normal usage under commonly accepted operating parameters and excludes consumable products.
Warranty period for repairs or used instrumentation purchased from Lafayette Instrument is 90 days. Lafayette Instrument Company agrees either to repair or replace, at its sole option and free of part charges to the customer, instrumentation which, under proper and normal conditions of use, proves to be defective within the warranty period. Warranty for any parts of such repaired or replaced instrumentation shall be covered under the same limited warranty and shall have a warranty period of 90 days from the date of shipment or the remainder of the original warranty period whichever is greater. This warranty and remedy are given expressly and in lieu of all other warranties, expressed or implied, of merchantability or fitness for a particular purpose and constitutes the only warranty made by Lafayette Instrument Company.
Lafayette Instrument Company neither assumes nor authorizes any person to assume for it any other liability in connection with the sale, installation, service or use of its  instrumentation. Lafayette Instrument Company shall have no liability whatsoever for special, consequential, or punitive damages of any kind from any cause arising out of  the sale, installation, service or use of its instrumentation.
All products manufactured by Lafayette Instrument Company are tested and inspected prior to shipment. Upon prompt notification by the Customer, Lafayette Instrument Company will correct any defect in warranted equipment of its manufacture either, at its option, by return of the item to the factory, or shipment of a repaired or replacement part. Lafayette Instrument Company will not be obliged, however, to replace or repair any piece of equipment, which has been abused, improperly installed, altered, damaged, or repaired by others. Defects in equipment do not include decomposition, wear, or damage by chemical action or corrosion, or damage incurred during shipment.

Limited Obligations Covered by this Warranty

  1. In the case of instruments not of Lafayette Instrument Company manufacture, the original manufacturer’s warranty applies.

  2. Shipping charges under warranty are covered only in one direction.
    The customer is responsible for shipping charges to the factory if return of the part is required.

  3. This warranty does not cover damage to components due to improper installation by the customer.

  4. Consumable and or expendable items, including but not limited to electrodes, lights, batteries, fuses, O-rings, gaskets, and tubing, are excluded from warranty.

  5. Failure by the customer to perform normal and reasonable maintenance on instruments will void warranty claims.

  6. If the original invoice for the instrument is issued to a company that is not the company of the end user, and not an authorized Lafayette Instrument Company  distributor, then all requests for warranty must be processed through the company that sold the product to the end user, and not directly to Lafayette Instrument Company.

Export License
The U.S. Department of Commerce requires an export license for any polygraph system shipment with an ULTIMATE destination other than: Australia, Japan, New Zealand  or any NATO Member Countries. It is against U.S. law to ship a Polygraph system to any other country without an export license. If the ultimate destination is not  one of the above listed countries, contact us for the required license application forms.

Lafayette Instrument logo3700 Sagamore Pkwy N
Lafayette, IN 47904 USA
Tel: 765-423-1505
info@lafayetteinstrument.com
www.lafayetteinstrument.com
© 2023 by Lafayette Instrument Company, Inc.
All Rights Reserved- Rel. 3.21.23