FEATURES
- CASAMBI LED DIMMER
- Power Supply: 12-24-48 Vdc
- Voltage output for LED strip and LED module
- Control of the White and Monochromatic Light
- Command: APP CASAMBI
- Local Command: n°1 Normal Open Push Button
- Control voltage outputs for R
- Adjusting the brightness up to completed off (Dim to Dark)
- Minimum Brightness level: down to 0,1%
- PWM Modulation
- Adjusting PWM frequency: 600 / 4000 Hz
- Adjusting output curve: Linear / Logarithmic
- Soft start and soft stop
- Soft Dimming regulation
- Extended temperature range
- 100% Functional test
PRODUCT DESCRIPTION
MINI-1CV-CASAMBI is a single channel LED dimmer, controllable via Bluetooth
using the Casambi APP or locally with a normally open push button.
The LED dimmer is suitable for driving Strip LED and LED modules, White and
monochromatic constant voltage loads. It is possible connect a power supply at
12-24-48 Vdc.
The maximum total output current is 12A. The LED dimmer has over voltage
protection, under voltage protection, reverse polarity protection and input
fuse protection.
By means of the CASAMBI APP, the MINI-1CV-CASAMBI allows you to make a variety
of effects: from simple brightness adjustments to more complex lighting
control system, thanks to the creation of multiple scenarios, animations,
timers, daylight control etc
CASAMBI APP can be downloaded for free on Apple App Store and Google Play
Store.
⇢ For the up-to-date manual, please visit our website:
www.dalcnet.com or scan the QR Code located on the
productlabel.
⇢ For the correct functioning of the CASAMBI APP, please visit the forum on
the Casambi website:
https://support.casambi.com/support/home
https://qr.dalcnet.com/q/MINI-1CV-CASAMBI
PRODUCT CODE
CODE | POWER SUPPLY | OUTPUT LED | N° OF CHANNEL | TYPE OF COMMAND |
---|---|---|---|---|
MINI-1CV-CASAMBI | 12-24-48 VDC | 1 x 12A | 1 | APP CASAMBI N°1 N.O. PUSH BUTTON |
PROTECTIONS
OVP| Over voltage protection|
---|---|---
UVP| Under voltage protection| ✔
RVP| Reverse polarity protection| ✔
IFP| Input fuse protection| ✔
TYPE OF PROFILE
NAME OF PROFILE | # PROFILE | DESCRIPTION |
---|---|---|
MINI 4kHz (Lin) | 9531 | One channel PWM dimmer |
Output PWM Frequency = 4000Hz
Linear dimming curve
PWM resolution 1000step
MINI 4kHz (Log)| 23372| One channel PWM dimmer
Output PWM Frequency = 4000Hz
Logarithmic dimming curve
PWM resolution 1000step
MINI 600Hz (Lin)| 24661| One channel PWM dimmer
Output PWM Frequency = 600Hz
Linear dimming curve
PWM resolution 1666step
MINI 600Hz (Log)| 22989| One channel PWM dimmer
Output PWM Frequency = 600Hz
Logarithmic dimming curve
PWM resolution 1666step
- The maximum output current depends on the operating conditions and the ambient temperature of the installation. For the correct configuration, check the maximum deliverable power in the “Technical Specifications” section and the “Operating Window”
- The protections refer to the logical control circuit.
REFERENCE STANDARDS
EN 55015| Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
---|---
EN 61547| Equipment for general lighting purposes – EMC immunity requirement
EN 61347-1| Lamp Controlgear – Part 1: General and safety requirement
EN 61347-2-13| Lamp Controlgear – Part 2-13: Particular requirement for d.c.
or a.c. supplied electronic Controlgear for LED modules
TECHNICAL SPECIFICATION
MINI 1 CV CASAMBI
Supply voltage| Min: 10,8Vdc – Max: 52,8Vdc
Output voltage| =Vin
Input current| Max 12A
Output current 3| max 12A @40°C – max 10A @60°C
**Nominal Power| 12 Vdc| 144W @12A – 120W @10A
24 Vdc| 288W @12A – 240W @10A
48 Vdc| 576W @12A – 480W @10A
Power loss in standby mode| < 0,5W
Type of load 4| R
Dimming curve| Logarithmic or Linear
Dimming range 5| 0,1 – 100%
Minimum dimming level| 0,1% (Logarithmic curve 600Hz)60,4% (Linear curve
600Hz)| 0,5% (Logarithmic curve 4kHz)0,5% (Linear curve 4kHz)
Dimming method| Pulse Width Modulation “PWM”
PWM frequency 5| 600 – 4000 Hz
PWM resolution 5| 1666 Step (600Hz)| 1000 Step (4kHz)
Operating frequencies 5| 2402 – 2480 MHz
Maximum output power 5| 7dBm
Storage temperature| Min: -40°C – Max: 60°C
Ambient temperature, Ta range 3| Min: -10°C – Max: 60°C
Connector type| Screw terminals
Wiring| Solid Size| 0,05 ÷ 2,5 mm2 / 30 ÷ 12 AWG
Stranded size
Wire strip length| 6,5 mm
IP protection grade| IP20
Casing material| Plastic
Packaging unit (pieces/unit)| 1pcs
Mechanical dimension| 44 x 57 x 25 mm
Packaging dimension| 56 x 68 x 35 mm
Weight**| 44g
3 For the complete range, see the Operating Window of the product.
4 Type of load: Resistive and DC/DC Converter.
5 The parameters are derived from the configuration of the Casaba module.
6 Dim to Dark Dimming.
WIRING DIAGRAM
As show in the wiring diagram carry out the following steps for the installation of the product.
- Connect the positive of the LED load to the “LED” terminals with the “+” symbol, and the negative of the LED load to the “LED” terminals with the “ “ symbol.
- Connect the N.O. push button to the “INPUT” terminals with the “ ” symbol. Be sure not to connect live parts to the “INPUT” terminals.
- Connect a 12-24-48 Vdc constant voltage SELV power supply (depending on the technical characteristics of LED load) to the “DC IN” terminal with the “+” and “-” symbols.
Be sure not to use constant current LED Driver and check that the polarity of the cables is correct.
Like any other product with Bluetooth control, be sure not to place the
product inside a metal case or next to large metal structures. The metal will
greatly block the radio signal, important for the correct operation of the
device.
LOCAL COMMANDS FUNCTIONALITY
N° Push Button| Functions| |
---|---|---|---
1| Controls a luminaire| Click Long press (>1s)| Tap to turn a luminaire
on or off – hold to adjust luminaire brightness
Controls an element| Click Long press (>1s)| Tap to turn a device element on
or off – hold eto adjust the element value
Control a group| Click Long press (>1s)| Tap to turn a group on or off – hold
to adjust brightness
Control scene| Click Long press (>1s)| Tap to turn a scene on or off – hold to
adjust scene brightness
Control all luminaires| Click Long press (>1s)| Tap to turn all luminaires on
or off – hold to adjust brightness
Cycles scenes| Click Long press (>1s)| Tap to cycle through the list of scenes
–hold to adjust current scene brightness
Active/Standby| Click Long press (>1s)| Tap to switch between two scenes –
hold to adjust current scene brightness
For all other functions, please refer to the CASAMBI APP document at:
https://support.casambi.com/support/home
UNPAIR DEVICE FROM THE CASAMBI NETWORK
If the device is associated with a network to which you do not have the
credentials and you want to associate it with a new one, follow the settings
specified in the Casambi APP in the “Nearby Devices” section. Once you have
selected the unpair function and started the procedure, turn off the main
power of the power supply connected to the MINI-1CV-CASAMBI and turn it on
again after 1 – 2 seconds.
If the main power supply is switched off and on again quickly, unpair may not
be done properly. Repeat the unpair sequence by allowing 1 or 2 more seconds
to elapse between the moment you turn off and re-turn on the main power of the
power supply8 .
A second method to unpair the product is to connect an N.O. push button to an
“INPUT” terminal of the MINI-1CV-CASAMBI and during the decoupling procedure
press the button.
7 By default, the N.O. Push button is set as “Control a luminaire” and
controls the output of the MINI-1CV-CASAMBI.
8 The discharge time of the power supply secondary depends on the construction
characteristics of the power supply used.
OPERATING WINDOW
Ambient temperature [Ta]:
– provides a current up to 12A, with a working temperature range of -10°C ÷
+40°C.
– provides a current up to 10A, with a working temperature range of +40°C ÷
+60°C.
These maximum current values can be applied only under proper ventilation
conditions.
FLICKER PERFORMANCE
Thanks to the 4khz dimming frequency the MINI-1CVCASAMBI allows to reduce the
Flicker phenomenon. Depending on the sensitivity of a person and the type of
activity, flickering can affect a person’s well-being even if the luminance
fluctuations are above the threshold that can be perceived by the human eye.
The graph shows the phenomenon of Flickering in function at the frequency,
measured throughout the dimming range. The results show the low-risk zone
(yellow) and the coeffect zone (green). Defined by IEEE 1789-2015 9
9 Institute of Electrical and Electronics Engineers (IEEE). IEEE std 1789:
Recommended Practices for Modulating Current in High- Brightness LEDs for
Mitigating Health Risks to Viewers.
DIMMING CURVE
MECHANICAL DIMENSION
TECHNICAL NOTE
INSTALLATION
- CAUTION: The product may only be connected and installed by a qualified electrician. All applicable regulations, legislation, and building codes must be observed. Incorrect installation of the product can cause irreparable damage to the product and the connected LEDs.
- Maintenance must be performed only by a qualified electrician in compliance with current regulations. Pay attention when connecting the LEDs: polarity reversal results in no light output and often damages the LEDs.
- The product is designed and intended to operate LED loads only. Powering non-LED loads may push the product outside its specified design limits and is, therefore, not covered by any warranty. Operating conditions of the product may never exceed the specifications as per the product datasheet.
- The product must be installed inside a switchgear/control gear cabinet and/or junction box protection against overvoltage.
- The product must be installed in a vertical or horizontal position with the label/top cover facing upwards or vertically. Other positions are not permitted. The bottom position is not permitted (label/top cover facing down).
- Keep separated 230Vac (LV) circuits and not SELV circuit from safety extra low voltage (SELV) circuit and from any connection with this product. It is absolutely forbitten to connect, for any reason whatsoever, directly or indirectly, the 230Vac mains voltage to the product (terminal block of BUS included).
- The product must be dissipated correctly.
- The use of the product in harsh environments could limit the output power.
- For built-in components inside luminaires, the ta ambient temperature range is a guideline given for the optimum operating environment. However, integrator must always ensure proper thermal management (i.e. correct mounting of the device, air flow etc.) so that the tc point temperature does not exceed the tic maximum limit in any circumstance. Reliable operation and lifetime is only guaranteed if the maximum tic point temperature is not exceeded under the conditions of use.
POWER SUPPLY
-
Only use SELV power supplies with limited current for device power supply, short circuit protection and the power must be dimensioned correctly.
In the case of power supplies equipped with ground terminals, it is mandatory to connect ALL protective ground points (PE= Protection Earth) to a properly and certified protection earth. -
The connection cables between the very low voltage power source and the product must be properly dimensioned and must be insulated from any wiring or part at non-SELV voltage. Use double insulated cables.
-
Dimension the power of the power supply in relation to the load connected to the device. In case the power supply is oversized compared to the maximum absorbed current, insert a protection against over-current between the power supply and the device.
COMMAND
- The length of the cables connecting between the local commands (N.O. Push button or other) and the product must be less than 10m. The cables must be properly dimensioned and must be insulated from any non-SELV wiring or voltage. It is recommended to use double insulated cables, if deemed appropriate also shielded.
- ALL device and control signal connected to the local command “N.O. Push button” with symbol, they must not supply any type of voltage.
OUTPUTS
It is recommended a length of the connecting cables between the product and
the LED module less than 10m. The cables must be properly dimensioned and must
be insulated from any wiring or circuits at voltage not SELV. It is
recommended to use double insulated cables. In case you want to use connecting
cables between the product and the LED module greater than 10m, the installer
must guarantee the correct operation of the system. In any case, the
connection between the product and the LED module must not exceed 30m.
ONLY CASAMBI/BLUETTOTH PRODUCT
- WARNING: For optimal functionality of the Casaba signal, do not put the device into metal or aluminium boxes and do not shield the device. As any other Casambi product, should not be placed in a metal enclosure or next to large metal structures. Metal will effectively block all radio signals which are crucial to the operation of the product.
WARNINGS
- To guarantee the best performances and the full use of functions, make sure to download on your device the last release of CASAMBI APP.
- Whenever CASAMBI APP requires an upgrade of the profile installed in the LED Dimmers, follow the instruction to do it. This allows you to stay always up to date and benefit of new functions released.
- Functionality test are done on all dimmers to ensure the right working. In case the device is still paired to “Dulcet network”, you are asked to unpair it by following the instructions on CASAMBI APP and in paragraph “UNPAIR DEVICE FROM THE CASAMBI NETWORK”.
DALCNET S.r.l.
36077 Alta villa Vicentine (VI) – Italy
Via Lago di Garda, 22
Phone +39 0444 1836680
www.dalcnet.com
info@dalcnet.com
Rev. 15/12/2022 – Pag. 8/8
References
- Led dimmer and RGB controller for professional lighting systems
- Led dimmer and RGB controller for professional lighting systems
- Support : Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>