DALCNET AIR-BRIDGE-DMX Lumenradio Wireless DMX Transmitter and Receiver User Manual
- June 29, 2024
- DALCNET
Table of Contents
DALCNET AIR-BRIDGE-DMX Lumenradio Wireless DMX Transmitter and Receiver
FEATURES
- LumenRadio wireless DMX transmitter and receiver
- Input voltage: typical 230 Vac @50Hz, range (85 ÷ 305) Vac
- Transmit a full-DMX universe with RDM capabilities
- External linking button
- Concurrent Bluetooth Low Energy features
- Over-the-air software upgrades
- Insulated DMX512 Input/Output
- Device configuration by LumenRadio CRMX Toolbox© mobile application
- Modes of Operation: Receiver (RX), Trasmitter (TX)
- IP67 enclosure with IP67 external SMA antenna
- Dimensions: 90x90x65mm (antenna excluded)
- 100% Functional Test
PRODUCT DESCRIPTION
AIR-BRIDGE-DMX is a Wireless transmitter and receiver powered by LumenRadio module with concurrent Bluetooth that convert DMX protocol to a wireless signal. Concurrent Bluetooth enables easy setup, configuration and lighting control using portable devices through LumenRadio CRMX Toolbox© mobile application.
AIR-BRIDGE-DMX uses wireless signals to rapidly transmit data packets from a transmitter to a receiver (usually near lighting fixtures). Instead of relying on traditional DMX cables, AIR-BRIDGE-DMX streamlines communication wirelessly, reducing setup time and costs for live productions. It’s like turning regular, wired DMX into a wireless signal, like how digital wireless microphones work. The data from the controller goes into a DMX connector on the wireless transmitter, and the data moves wirelessly through the air. AIR- BRIDGE-DMX transmitter can be easily paired with other receivers by means of external pushbutton that enable the linking connection between Master transmitter (TX) and Slaves Receivers (RX). Through the LumenRadio CRMX Toolbox© mobile application it is possible to setup and configure multiple parameters of the AIR-BRIDGE-DMX, such as modes of operation Transmitter (TX) or Receiver (RX). LumenRadio CRMX Toolbox© can be downloaded free of charge from the Apple App Store and Google Play Store. ⇢ For the most up-to-date manual, please visit our website: www.dalcnet.com or the QR Code directly on your device.
PRODUCT CODE
| | |
---|---|---|---
CODE| POWER SUPPLY| REMOTE CONTROL (BUS)| APP CONFIG
AIR-BRIDGE- DMX| 85 ÷ 305 Vac @50Hz| LumenRadio wireless DMX512-RDM|
LumenRadio CRMX Toolbox©
REFERENCE STANDARDS
AIR-BRIDGE-DMX is compliant to the standards shown in the following table.
STANDARD | TITLE |
---|
EN IEC 62368-
1:2020+A11:2020
| Audio/Video, information and communication technology equipment – Part 1:
Safety requirements
ANSI E1.11| Entertainment Technology – USITT DMX512-A – Asynchronous
Serial Digital Data Transmission
Standard for Controlling Lighting Equipment and Accessories
ANSI E1.20| Entertainment Technology-RDM-Remote Device Management over USITT DMX512 Networks
TECHNICAL SPECIFICATIONS
PARAMETERS | VALUES | |
---|---|---|
INPUT | Supply Voltage Nominal (Vin) | 230 Vac |
Power Supply Range (Vmin ÷ Vmax) | (85 ÷ 305) Vac | |
Mains Frequency | 50 Hz | |
Efficiency at full load | > 95% | |
Power consumption awaiting command (standby) | < 0,5 W | |
ENVITONMENTAL | Storage Temperature (Tstock_min ÷ Tstock_max) | (-40 ÷ |
+60) °C
Working ambient temperature (Tamb_min ÷ Tamb_max)1| (-20 ÷ +60) °C
Connector Type
| PWR and DMX (Internal)| Screw terminals
Cable Gland| IP67 cable glands
Antenna| IP67 Coaxial SMA
Wiring Section| Solid size| 0,2 ÷ 1,5 mm2
Stranded size| 24 ÷ 16 AWG
Stripping| 9 ÷ 10 mm
Protection class| IP67
Casing Material| Plastic
Packaging units (piece/units)| 2pz
Mechanical Dimensions (antenna excluded)| 90 x 90 x 65 mm
Package Dimensions| 262 x 177 x 81 mm
INSTALLATION
WARNING! Installation and maintenance must always be carried out in the absence of voltage. Before proceeding with the connection of the device to the power supply, make sure that the voltage of the power source is disconnected from the system. The device should only be connected and installed by qualified personnel. All applicable regulations, legislation, standards, and building codes must be adhered to. Incorrect installation of the device may cause irreparable damage to the device and connected loads. The following paragraphs show the diagrams of the dimmer’s connection to the remote control, the load and the supply voltage.
It is recommended to follow these steps to install the product safely:
- Connecting the Remote Control: Connect the DMX data bus signals “D+”, “D-“ and “COM” to the internal “DMX” terminal.
- Power connection: Connect a 230 Vac mains voltage to the “N” and “L” terminal of the internal AC IN connector.
REMOTE CONTROL CONNECTION
AIR-BRIDGE-DMX can propagate the wired DMX digital bus (a shielded and twisted
two-wire cable) through the air by means of the provided antenna. Each AIR-
BRIDGE-DMX can be configured as transmitter (TX) or receiver (RX) manually via
the internal jumper selector or remotely via Bluetooth with LumenRadio CRMX
Toolbox© mobile application.
Note : to use the remote configuration via Bluetooth, remove the jumper
from selector.
To connect AIR-BRIDGE-DMX to the DMX network, simply connect the DMX data bus signals “D+”, “D-“ and “COM” to the internal “DMX” terminal (refer to Figure 1). To maintain proper IP (Ingress Protection) rating, ensure the following:
- Cable Section: use a cable with the correct cross-sectional area (gauge) suitable for the application.
- Proper Crimping: when connecting the cable to the provided cable gland, ensure it is crimped correctly. Proper crimping ensures a secure and reliable connection, preventing water or dust ingress. Remember that maintaining IP protection involves both the choice of materials (such as the cable) and the quality of installation. The most commonly used connectors are 3-pole and 5-pole XLR, where one pin is the cable shield (ground) and 2 pins are used for DMX signal transmission. In the case of 5-pole XLR, the other 2 pins are reserved for a secondary DMX balanced line2.
AIR-BRIDGE-DMX
Signal Description| Pin# (3-Pin XLR)| Pin# (5-Pin XLR)|
DMX512 Function
---|---|---|---
Common Reference| 1| 1| Data-Link Common
Primary Data-Link| 2| 2| Data 1-
3| 3| Data 1+
Secondary Data-Link2| –| 4| Data 2-
–| 5| Data 2+
LUMENRADIO WIRELESS DMX TOPOLOGY
Figure 3 shows the connection topology supported by AIR-BRIDGE-DMX through the
Wireless technology.
POWER SUPPLY CONNECTION
AIR-BRIDGE-DMX can be powered by Mains AC Voltage supply at 230 Vac @50Hz.
Once the remote control (DMX bus) is connected, connect the power supply to
the “N” and “L” terminals of the AC IN terminal (refer to Figure 1).
REMOTE CONTROL: LUMENRADIO WIRELESS DMX512+RDM
The DMX512 protocol (or DMX), is a digital communication standard used primarily for controlling stage lighting in the entertainment industry and allows numerous lights and effects to be controlled from a control room. Recently, it has also been introduced in architectural lighting. The DMX512 is based on the physical RS-485 protocol: an RS485 industrial line, i.e. a shielded bipolar cable with a nominal impedance of 110Ω, is therefore used to connect a DMX512 controller to compatible equipment. The Remote Device Management (RDM) extension offers a significant improvement by introducing two-way communication between controllers and connected compatible RDM devices. It allows devices to be controlled and communicated in both directions, making it easy to install and configure the devices and enabling intelligent management from the control console through the information sent by the RDM devices. Some of the benefits of RDM include:
- Remote access to driver address settings from the command console (or DMX controller)
- Automatic device search: The controller can search the DMX universe for all connected devices and route them automatically
- Status communication, faults, temperature, etc.: RDM devices can send information about their operating status and any faults to the console
LumenRadio wireless DMX is a technology that replaces traditional DMX cables in lighting systems. A wireless transmitter converts regular wired DMX data into a wireless signal. The wireless signal is received by a wireless receiver, which then converts it back into regular DMX data. The goal of LumenRadio wireless DMX is to eliminate the need for long, expensive DMX cable runs, saving time and cost for live productions. It ensures seamless transmission within a single event space, preventing signal breaks. AIR- BRIDGE-DMX natively supports the RDM functionality of the DMX protocol also with LumenRadio wireless DMX technology.
TRANSMITTER/RECEIVER SETTINGS
The AIR-BRIDGE-DMX can operate as a transmitter or a receiver. The operative
mode can be selected by means the TX/RX internal jumper selection.
WARNING! Maintenance must always be carried out in the absence of voltage. Before proceeding with the TX/RX jumper selection, make sure that the voltage of the power source is disconnected from the system.
The operative mode can be selected in the following two ways:
- Manually : selecting the Trasmitter (TX) or Receiver (RX) operating mode through the onboard TX/RX jumper selector.
- Remotely: removing the jumper from selector pins and using the LumenRadio CRMX Toolbox© mobile application available for Android and iOS.
LINKING PROCEDURE
To be able to transmit data through the system, receivers need to be linked to
the appropriate transmitter or repeater.
- Make sure the receivers are unlinked and that they are withing communication range.
- If receiver is already linked, follow the steps in the unlink section.
- Press the link switch momentarily on the transmitter.
- Wait for the linking process to finish. Every transmitter can be linked to multiple receivers.
UNLINKING PROCEDURE
Unlinking can be done directly from the transmitter, which will unlink all
currently powered receivers that are within range that is linked to this
transmitter. This is done by holding the link switch on the transmitter for >3
s. Unlinking can also be done on one specific receiver by holding pressed its
link switch for >3 s.
BLUETOOTH LOW ENERGY
Bluetooth Low Energy (or BLE) is enabled by default. It is recommended to
disable the BLE interface after installation has been completed, or to protect
the BLE interface by setting a PIN code. To enable or disable the BLE
interface, operate to the Link switch performing a double short press followed
by a single long press. During the Bluetooth connection to the AIR-BRIDGE-DMX,
the CRMX signal strength may be significantly reduced. Therefore is not
recommended to use the Bluetooth configuration app once the Wireless
connection has occurred, otherwise the TX/RX device can be disconnected from
the Wireless network.
TECHNICAL NOTES
INSTALLATION
WARNING! Installation and maintenance should always be carried out in the absence of AC voltage. Before proceeding with the installation, adjustment, and connection of the device to the power supply, make sure that the voltage is disconnected from the system. The device should only be connected and installed by qualified personnel. All applicable regulations, legislation, standards, and building codes in force in the respective countries must be adhered to. Incorrect installation of the device may cause irreparable damage to the device and connected loads. Maintenance must only be carried out by qualified personnel in compliance with current regulations. The product must be installed inside an electrical panel and/or junction box that is protected against overvoltage. The external power supply must be protected. The product must be protected by a properly sized circuit breaker with overcurrent protection.
Keep 230 Vac (LV) circuits and non-SELV circuits separate from SELV safety ultra-low voltage circuits and any product connections. It is strictly forbidden to connect, for any reason, directly or indirectly, the 230 Vac mains voltage to the control terminals (DMX bus) of the product. The product must be installed in a vertical or horizontal position, i.e. with the antenna facing upwards or laterally. No other positions are allowed. The bottom position, i.e. with the antenna facing downwards, is not allowed. During installation, it is recommended to reserve adequate space around the device to facilitate its accessibility in case of future maintenance or updates.
Use in thermally harsh environments may limit the output power of the product. For devices embedded within luminaires, the TA ambient temperature range is a guideline to be carefully observed for the optimal operating environment. However, the integration of the device within the luminaire must always ensure proper thermal management (e.g. correct mounting of the device, proper ventilation, etc.) so that the temperature at the TC point does not exceed its maximum limit under any circumstances. Proper operation and durability are only guaranteed if the maximum temperature of the TC point is not exceeded under the conditions of use.
POWER SUPPLY
The device must be powered only with Mains AC power source, short-circuit
protection and suitably sized power according to the specifications indicated
in the product data sheet. No other types of power supply are permitted.
Connecting to an unsuitable power supply may cause the device to operate
outside of the specified design limits, voiding its warranty. In the case of
power supplies equipped with earth terminals, it is mandatory to connect ALL
the protection earth points (PE= Protection Earth) to a state-of-the-art and
certified earthing system. The power cables of the device must be correctly
sized with reference to the connected load and must be isolated from any
wiring or equal to SELV voltage. Use double-insulated cables.
REMOTE CONTROL
The length and type of cables connecting to the buses must comply with the
specifications of the respective protocols and cur rent regulations. They must
be isolated from any non-SELV wiring or live parts. It is recommended to use
double-insulated cables.
WIRELESS WARNINGS
The Bluetooth Low Energy (BLE) connection is performed throught the provided
antenna, located on the top of the device. BLE technology works optimally
through non-metallic materials. Therefore, it is not recommended to place the
device inside metal boxes or reflective surfaces when using BLE. For reliable
communication, make sure that the antenna is not covered or that it is free of
metal objects, wiring, or other electronic devices. Any impediments could
affect the quality of communication. BLE technology works at a medium
distance, generally < 100m. Make sure that the product and your device are
close enough to allow communication.
During firmware update and configuration, you should maintain stable contact between your smartphone and the device for the entire duration of the process. This ensures that the update goes smoothly, and that the device is ready to use after the process is complete. Ensure that the device is positioned in an area with good signal coverage. Avoid obstacles like thick walls or metallic objects that could attenuate the signal. Avoid placing the device near other electronic equipment or sources of interference (such as microwave ovens or cordless phones). Interference can degrade signal quality. Periodically check if firmware or software updates are available for the device. Updates often improve stability and security.
LEGAL NOTES
TERMS OF USE
Dalcnet Srl (hereinafter referred to as “the Company”) reserves the right to
make changes to this device, in whole or in part, without prior notice to the
customer. Such changes may affect technical aspects, functionality, design, or
any other element of the device. The company is not required to notify you of
such changes and that your continued use of the device will constitute your
acceptance of the changes. The company is committed to ensuring that any
changes do not compromise the essential functionality of the device and that
they comply with applicable laws and regulations. In the event of substantial
changes, the company undertakes to provide clear and timely information on the
same. The customer is advised to periodically consult the
www.dalcnet.com website or other official
sources to check for any updates or changes to the device.
DALCNET S.r.l.
36077 Altavilla Vicentina (VI) – Italy
Via Lago di Garda, 22.
Tel. +39 0444 1836680
www.dalcnet.com
info@dalcnet.com
References
- Led dimmer and RGB controller for professional lighting systems
- Led dimmer and RGB controller for professional lighting systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>