Dalcnet LINE-5CV-CASAMBI LED dimmer Plus Casambi Driver Owner’s Manual
- June 12, 2024
- DALCNET
Table of Contents
- Dalcnet LINE-5CV-CASAMBI LED dimmer Plus Casambi Driver
- **Features
- Product Description
- PRODUCT CODE
- Protections
- Type of Profiles
- Reference Standards
- Technical Specifications
- Product Usage Instructions
- WIRING DIAGRAM
- LOCAL COMMANDS FUNCTIONALITY
- UNPAIR DEVICE FROM THE CASAMBI NETWORK
- OPERATING WINDOW
- FLICKER PERFORMANCE
- DIMMING CURVE
- MECHANICAL DIMENSIONS
- TECHNICAL NOTE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Dalcnet LINE-5CV-CASAMBI LED dimmer Plus Casambi Driver
**Features
**
The LINE-5CV-CASAMBI enables you to make not only simple brightness adjustments but also more intricate lighting control systems. This is made possible through the creation of multiple scenarios, animations, timers, daylight controls, and more.
- DIMMER LED CASAMBI
- Power Supply: 12-24-48 Vdc
- Voltage Output for strip LED and LED module
- WHITE, MONOCOLOR, DYNAMIC WHITE, RGB, RGB+W, RGB+WW and RGB+TW Light Control
- Command: CASAMBI APP
- Local Command: N°2 Button Normally Open
- Control voltage output R
- Minimum brightness level: down to 0.8%
- PWM Modulation
- Frequency PWM 4000Hz
- Linear curve
- Soft start and soft stop
- Soft dimming of brightness
- Extended temperature range
- 100% Functional Test
Product Description
The LINE-5CV-CASAMBI is a lighting control device that allows for simple brightness adjustments as well as more complex lighting control systems. It supports the creation of multiple scenarios, animations, timers, daylight controls, and more.
- Product Code CODE LINE-5CV-CASAMBI
- Supply Voltage 12-24-48 VDC
- LED Output 5 x 5A (max 12A)
For the always updated manual, consult our website: www.dalcnet.com or QR Code
For the correct functioning of the CASAMBI APP, consult the forum on the
Casambi website: https://support.casambi.com/support/home
PRODUCT CODE
CODE| SUPPLY VOLTAGE| LED OUTPUT| N° OF CHANNELS| TYPE OF
COMMAND
---|---|---|---|---
LINE-5CV-CASAMBI| 12-24-48 VDC| 5 x 5A (max 12A)1| 5| APP CASAMBI
N°2 Button N.O.
Protections
- OVP Over voltage protection
- UVP Under voltage protection
- RVP Reverse polarity protection
- IFP Input fuse protection
Type of Profiles
- LINE 5xDIM (Lin)
- LINE TWxTW (Lin)
- LINE RGB (Lin)
- LINE RGB+W (Lin)
- LINE RGB+W+W (Lin)
- LINE RGB+TW (Lin)
The maximum output current depends on the operating conditions and the ambient
temperature of the installation. For the correct configuration, check the
maximum deliverable power in the “Technical Specifications” section and the
“Operating Window”.
Protections refer to the control logic of the board.
Reference Standards
- EN 55015
- EN 61547
- EN 61347-1
- EN 61347-2-13
Technical Specifications
- Supply voltage: 12 Vdc, 24 Vdc, 48 Vdc
- Output voltage: =Vin
- Input current: Max 12A
- Output current: 5x max 5A, 1x max 12A
- Nominal power: 60W, 144W, 120W, 288W, 240W, 579W
- Power loss in standby mode: < 0.5W
- Type of load: Resistive and DC/DC Converter
- Dimming curves: Linear
- Dimming range: 0.8% (Linear curve 4kHz)
- Minimum dimming level: Pulse Width Modulation (PWM)
- PWM Frequency: 4000 Hz
- PWM Resolution: 1000 Step
- Operating Frequencies: 7dBm
- Type of connector: Push-In terminals
- Wiring section: 186 x 29 x 21 mm
- Wire strip length: 197 x 34 x 29 mm
- IP protection grade: 71g
For the full range check the “Operating Window” of product.
Type of load: Resistive and DC/DC Converter.
The parameters are derived from the configuration of the Casambi module.
Product Usage Instructions
- 1. Download the CASAMBI APP for free from the Apple App Store or the Google Play Store.
- For the always updated manual, consult our website: www.dalcnet.com
- For the correct functioning of the CASAMBI APP, consult the forum on the Casambi website: https://support.casambi.com/support/home
- Follow the wiring diagram provided in the user manual for product installation.
- Make sure not to connect live parts to INPUT terminals.
- Connect the DC IN terminal block with the + and – symbols, ensuring the correct polarity of the cables.
- Avoid placing the product inside a metal case or near large metal structures as it may obstruct the radio signal necessary for proper functioning of the device.
WIRING DIAGRAM
Follow the steps below for product installation as shown in the connection diagram:
- Connect the positive of the LED load to the “L” terminal with the “+” symbol, instead the negatives of the LED load to the terminals “L1”, “L2”, “L3”, “L4” and “L5” with the “-” symbol.
- Connect the N.O. push button to the “INPUT 1” and “INPUT 2” terminals with the ” symbol. ” Be sure not to connect live parts to “INPUT” terminals.
- Connect a 12-24-48 Vdc constant voltage SELV power supply (depending on the technical characteristics of LED load) to the DC IN terminal block with the “+” and “-” symbols.
Be sure not to use constant current LED Driver and check that the polarity of the cables is correct.
Like any other product with Bluetooth control, be sure not to place the product inside a metal case or placed near large metal structures. The metal will significantly obstruct the radio signal, which is crucial for the proper functioning of the device.
LOCAL COMMANDS FUNCTIONALITY
N.O. PUSH BUTTON6
N° Button| Function| |
---|---|---|---
1-2
| Controls a luminaire| Click
Long pressure (>1s)
| Tap to turn a luminaire on or off – hold to adjust
luminaire brightness
Controls an element| Click
Long pressure (>1s)
| Tap to turn a device element on or off – hold to
adjust the element value
Control a group| Click
Long pressure (>1s)
| Tap to turn a group on or off – hold to adjust
brightness
Control scene| Click
Long pressure (>1s)
| Tap to turn a scene on or off – hold to adjust scene
brightness
Control all luminaires| Click
Long pressure (>1s)
| Tap to turn all luminaires on or off – hold to adjust
brightness
Cycles scenes| Click
Long pressure (>1s)
| Tap to cycle through the list of scenes – hold to
adjust current scene brightness
Active/Standby| Click
Long pressure (>1s)
| Tap to switch between two scenes – hold to adjust
current scene brightness
For all other functions consult the documentation of the CASAMBI APP at:
https://support.casambi.com/support/home
UNPAIR DEVICE FROM THE CASAMBI NETWORK
If the device is already connected to a network for which you don’t have the
credentials and you wish to associate it with a new network, please follow the
instructions provided in the Casambi APP’s “Nearby Devices” section.
Once you have selected the unpair function and started the procedure, turn off
the main power of the power supply connected to the LINE-5CV-CASAMBI and turn
it on again after 1 – 2 seconds.
If the main power supply is switched off and on again quickly, unpair may not
be done properly. Repeat the unpair sequence by allowing 1 or 2 more seconds
to elapse between the moment you turn off and re-turn on the main power of the
power 7.
A second method to unpair the product is to connect an N.O. push button to an
“INPUT” terminal of the LINE-5CV-CASAMBI and during the decoupling procedure
press the button.
OPERATING WINDOW
Ambient temperature [Ta]:
– provides a current up to 12A, with a working temperature range of -10°C ÷
+60°C.
These maximum current values can be applied only under proper ventilation
conditions.
FLICKER PERFORMANCE
Thanks to its 4kHz dimming frequency, the LINE-5CV-CASAMBI effectively reduces
the occurrence of the Flicker phenomenon. Depending on an individual’s
sensitivity and the nature of their activities, flickering can impact one’s
well-being, even if the changes in luminance are beyond the threshold
detectable by the human eye.
The graph shows the phenomenon of Flickering in function at the frequency,
measured throughout the dimming range.
The results show the low-risk zone (yellow) and the no-effect zone (green).
Defined by IEEE 1789-20158
DIMMING CURVE
MECHANICAL DIMENSIONS
TECHNICAL NOTE
INSTALLATION
-
CAUTION: The product may only be connected and installed by a qualified electrician. All applicable regulations, legislation, and building codes must be observed. Incorrect installation of the product can cause irreparable damage to the product and the connected LEDs.
-
Maintenance must be performed only by a qualified electrician in compliance with current regulations.
Pay attention when connecting the LEDs: polarity reversal results in no light output and often damages the LEDs. -
The product is designed and intended to operate LED loads only. Powering non-LED loads may push the product outside its specified design limits and is, therefore, not covered by any warranty.
Operating conditions of the product may never exceed the specifications as per the product datasheet. -
The product must be installed inside a switchgear/controlgear cabinet and/or junction box protection against overvoltage.
-
The product must be installed in a vertical or horizontal position with the label/top cover facing upwards or vertically. Other positions are not permitted. The bottom position is not permitted (label/top cover facing down).
-
Keep separated 230Vac (LV) circuits and not SELV circuit from safety extra low voltage (SELV) circuit and from any connection with this product. It is absolutely forbitten to connect, for any reason whatsoever, directly or indirectly, the 230Vac mains voltage to the product (terminal block of BUS included).
-
The product must be dissipated correctly.
-
The use of the product in harsh environments could limit the output power.
-
For built-in components inside luminaires, the ta ambient temperature range is a guideline given for the optimum operating environment. However, integrator must always ensure proper thermal management (i.e. correct mounting of the device, air flow etc.) so that the tc point temperature does not exceed the tc maximum limit in any circumstance. Reliable operation and lifetime is only guaranteed if the maximum tc point temperature is not exceeded under the conditions of use.
POWER SUPPLY
-
Only use SELV power supplies with limited current for device power supply, short circuit protection and the power must be dimensioned correctly.
In the case of power supplies equipped with ground terminals, it is mandatory to connect ALL protective ground points (PE= Protection Earth) to a properly and certified protection earth. -
The connection cables between the very low voltage power source and the product must be properly dimensioned and must be insulated from any wiring or part at non-SELV voltage. Use double insulated cables.
-
Dimension the power of the power supply in relation to the load connected to the device. In case the power supply is oversized compared to the maximum absorbed current, insert a protection against over-current between the power supply and the device.
COMMAND
- The length of the cables connecting between the local commands (N.O. Push button or other) and the product must be less than 10m. The cables must be properly dimensioned and must be insulated from any non-SELV wiring or voltage. It is recommended to use double insulated cables, if deemed appropriate also shielded.
ALL device and control signal connected to the local command “N.O. Push button” with symbol, they must not supply any type of voltage.
OUTPUTS
- It is recommended a length of the connecting cables between the product and the LED module less than 10m. The cables must be properly dimensioned and must be insulated from any wiring or circuits at voltage not SELV. It is recommended to use double-insulated cables. In case you want to use connecting cables between the product and the LED module greater than 10m, the installer must guarantee the correct operation of the system. In any case, the connection between the product and the LED module must not exceed 30m.
- ONLY CASAMBI/BLUETOOTH PRODUCT
- WARNING: For optimal functionality of the Casambi signal, do not put the device into metal or aluminum boxes and do not shield the device. As any other Casambi product, should not be placed in a metal enclosure or next to large metal structures. Metal will effectively block all radio signals which are crucial to the operation of the product.
WARNINGS
- To guarantee the best performances and the full use of functions, make sure to download on your device the last release of CASAMBI APP.
- Whenever CASAMBI APP requires an upgrade of the profile installed in the LED Dimmers, follow the instruction to do it. This allows you to stay always up to date and benefit of new functions released.
- Functionality test are done on all dimmers to ensure the right working. In case the device is still paired to “Dalcnet network”, you are asked to unpair it by following the instructions on CASAMBI APP and in paragraph “UNPAIR DEVICE FROM THE CASAMBI NETWORK”.