BITMAIN Antminer K7 CKB COIN MINER Installation Guide
- June 9, 2024
- BITMAIN
Table of Contents
BITMAIN Antminer K7 CKB COIN MINER
INTRODUCTION
Document Version 2.0
Feb. 2023
BITMAIN warrants the performance of its products to the specifications applicable at the time of sale in accordance with BITMAIN’s standard warranty. Testing and other quality control techniques are used to the extent BITMAIN deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
BITMAIN assumes no liability for third-party application assistance. Customers are responsible for their products and applications using BITMAIN components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.
Resale of BITMAIN products or services with statements different from or beyond the parameters stated by BITMAIN for that product or service voids all express and any implied warranties for the associated BITMAIN product or service and is an unfair and deceptive business practice. BITMAIN is not responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered trademarks of their respective holders.
K7 Server Installation Guide
Overview
The K7 server is BITMAIN’s newest version in this series. Power supply
APW12 is part of K7 server. All K7 servers are tested and configured prior to
shipping to ensure easy set up.
K7 Server Components
The main components and controller front panel of K7 servers are shown in
the following figure:
Specifications
Model| Crypto Algorithm/Coins| Hashrate, TH/s| Power on wall@25, Watt| Power
supply AC input voltage, Volt (1-1)| Power supply AC Input Frequency Range,
Hz| Power supply AC Input current, Amp(1-2)| Network connection mode| Server
Size (LengthWidthHeight, w/o package), mm(2-1)| Server Size
(LengthWidthHeight, with package), mm| Net weight, kg (2-2)| Gross weight,
kg
---|---|---|---|---|---|---|---|---|---|---|---
K7-63.5T| | 63.5| | 200~240| 47~63| 20(1-3)| RJ45 Ethernet 10/100M|
430195.5290| 570316430| 16.1| 17.7
K7-58T| | 58| | | | | | | | |
Product Usage Instructions
To use the K7 server, follow these steps:
- Ensure that you have received all the components of the K7 server as shown in the figure in section 1.1.
- Refer to the specifications in section 1.2 to ensure that the power supply and other requirements are met.
- Connect the K7 server to a power source using the APW12 power supply and two additional power cords.
- Connect the K7 server to a network using an RJ45 Ethernet cable.
- Turn on the K7 server and wait for it to initialize.
- You can now use the K7 server for your desired applications.
Overview
The K7 server is BITMAIN’s newest version in this series. Power supply APW12 is part of K7 server. All K7 servers are tested and configured prior to shipping to ensure easy set up.
Caution:
- Please refer to the layout above to place your goods in usage in case of any damage.
- The equipment must be connected to an earthed mains socket outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
- The equipment has two power inputs. Only by connecting those two power supply sockets simultaneously can the equipment run normally. When the equipment is powered off, be sure to power off all power inputs.
- DO NOT remove any screws and cables tied on the product.
- DO NOT PRESS the metal button on the cover.
- Please note that the actual server shall prevail.
K7 Server Components
The main components and controller front panel of K7 servers are shown in the
following figure:
APW12 Power Supply:
Note:
- Power supply APW12 is part of K7 server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed.
Product Specifications
Model: K7-63.5T
Hashrate: 63.5 TH/s
Product Glance | Value |
---|---|
Version | 240-K |
Model | K7-63.5T |
Crypto Algorithm/Coins | Eaglesong |
Hashrate, TH/s | 63.5 ±3% |
power on wall@25℃, Watt | 3080 ±10% |
power efficiency on wall @ 25°C , J/TH | 48.5 ±10% |
Detailed Characteristics | Value |
Power Supply
Power supply AC input voltage, Volt (1-1)| 200~240
Power supply AC Input Frequency Range, Hz| 47~63
Power supply AC Input current, Amp (1-2)| 20 (1-3)
Hardware Configuration
Network connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2-1)|
430195.5290
Server Size (LengthWidthHeight, with package), mm
| ****
570316430
Net weight, kg (2-2)| 16.1
Gross weight, kg| 17.7
Environment Requirements
Operation temperature, °C| 0~40
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%
Operation altitude, m (3-1)| ≤ 2000
Model: K7-58T
Hashrate: 58 TH/s
Product Glance | Value |
---|---|
Version | 240-K |
Model | K7-58T |
Crypto Algorithm/Coins | Eaglesong |
Hashrate, TH/s | 58 ±3% |
power on wall@25℃, Watt | 2813 ±10% |
power efficiency on wall @ 25°C , J/TH | 48.5 ±10% |
Detailed Characteristics | Value |
Power Supply
Power supply AC input voltage, Volt (1-1)| 200~240
Power supply AC Input Frequency Range, Hz| 47~63
Power supply AC Input current, Amp (1-2)| 20 (1-3)
Hardware Configuration
Network connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2-1)|
430195.5290
Server Size (LengthWidthHeight, with the package), mm
| ****
570316430
Net weight, kg (2-2)| 16.1
Gross weight, kg| 17.7
Environment Requirements
Operation temperature, °C| 0~40
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%
Operation altitude, m (3-1)| ≤ 2000
Notes:
- Caution: Wrong input voltage may probably cause Server damaged
- Max condition: temperature 40°C, altitude 0m
- Two AC input wires, 10A per wire
- Including PSU size
- Including PSU weight
- When the Server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m
Setting up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only
- Go to the following site:https://service.bitmain.com/support
- Download the following file: IPReporter.zip.
- Extract the file. The default DHCP network protocol distributes IP addresses automatically.
- Right-click IPReporter.exe and run it as Administrator.
- Select one of the following options:
- Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
- Default – suitable for home servers.
- Click Start.
- On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds). The IP address will be displayed in a window on your computer screen.
- In your web browser, enter the IP address provided.
- Proceed to log in using root for both the username and password.
- In the Protocol section, you can assign a Static IP address (optional).
- Enter the IP address, Subnet mask, gateway and DNS Server.
- Click “Save”.
- Click https://support.BITMAIN.com/hc/en-us/articles/360018950053 to learn more about gateway and DNS Server
Setting up the Server
Configuring the Server
Setting up the Pool To configure the server:
- Click Settings marked below. Note:
- Fan speed percentage can be adjusted, but we recommend to keep the default setting. The server will adjust the fan speed automatically if the fan speed percentage has yet been selected.
- There are two working modes of K7 server: Normal mode and Sleep mode. The server enters the sleep mode under the condition that the control board is powered while hashboards are not powered.
- Set the options according to the following table:
Option| Description
---|---
Mining address| Enter the address of your desired pool.
The K7 servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher-priority pools are offline.
Name| Your worker ID on the selected pool.
Password (optional)| The password for your selected worker.
3. Click Save after the configuration.
Monitoring Your Server
To check the operating status of your server:
- Click the dashboard marked below to check the server status (taking K7-63.5T as an example).
- Monitor your server according to the descriptions in the following table:
Note: The K7-63.5T server is with a fixed frequency of 665 MHz. Firmware will stop running when the Temp (Outlet) reaches to 95℃,there will be an error message “high temp exceed limit (Overtemperature duration/s), max_chip_temp = (chip-real-temperature), max_pcb_temp = (board-real-temperature)!” shown on the bottom of kernel log page. Meanwhile, the server temperature on the dashboard interface turns abnormal and shows “Temp is too high”.
Option | Description |
---|---|
Number of chips | The number of chips detected in the chain. |
Frequency | ASIC frequency setting. |
Real Hashrate | Real-time Hashrate of each hash board (GH/s). |
Inlet Temp | The temperature of the inlet (°C). |
Outlet Temp | The temperature of the outlet (°C). |
Chip state | One of the following statuses will appear: |
● The Green Icon – indicates normal
● The Red Icon – indicates abnormal
Administering Your Server
Checking Your Firmware Version To check your firmware version:
- Enter the backstage of your server, find the firmware version on the bottom.
- Firmware Version displays the date of the firmware your server uses. In the examples below, the server is using firmware version 20230111.
Upgrading Your System
Make sure that the K7 server remains powered during the upgrade process. If
power fails before the upgrade is completed, you will need to return it to
BITMAIN for repair.
To upgrade the server’s firmware:
- In System, click Firmware Upgrade
- For Keep Settings:
- Select “keep settings” to keep your current settings (default).
- Unselect “keep settings” to reset the server to default settings.
- Click the button and navigate to the upgrade file. Select the upgrade file, then click Update.
- When the upgrade is completed, restart the server and it will turn to the setting page.
Modifying Your Password
To change your login password:
- In the System, click the Password tab.
- Set your new password, then click Save.
Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Environmental Requirements
Please run your server in accordance with the following requirements
-
Basic Environmental Requirements:
-
Climatic Conditions:
Description| Requirement
---|---
Operating Temperature| 0-40℃
Operating Humidity| 10-90%RH (non-condensing)
Storage Temperature| -20-70℃
Storage Humidity| 5-95%RH(non-condensing)
Altitude| <2000m -
Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources:
For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km. For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km. For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km. If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source. Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, and equipped with air conditioning for cooling. -
Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables, transmission lines, and high-current equipment, for example, there should be no high-power AC transformers (>10KA) within 20 meters, and no high-voltage power lines within 50 meters. Please keep your site away from high-power radio transmitters, for example, there should be no high-power radio transmitters (>1500W) within 100 meters.
-
-
Other Environmental Requirements:
The server running room shall be free of explosive, conductive, magnetically conductive, and corrosive dust. The requirements of mechanical active substances are shown below:- Requirements of Mechanical Active Substances
Mechanical Active Substance| Requirement
---|---
Sand| <= 30mg/m3
Dust (suspended)| <= 0.2mg/m3
Dust (deposited)| <=1.5mg/m2h - Requirements of Corrosive Gas
Corrosive Gas| Unit| Concentration
---|---|---
H2S| ppb| < 3
SO2| ppb| < 10
Cl2| ppb| < 1
NO2| ppb| < 50
HF| ppb| < 1
NH3| ppb| < 500
O3| ppb| < 2
Note: ppb (part per billion) refers to the unit of concentration 1ppb stands for the volume ratio of part per billion.
- Requirements of Mechanical Active Substances
Regulations:
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference
- this device must accept any interference received, including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Households in
the European Union
This symbol on the product or on its packaging indicates that this product
must not be disposed of with your other household waste. Instead, it is your
responsibility to dispose of your waste equipment by handing it over to a
designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your waste
equipment for recycling, please contact your local city office, your household
waste disposal service or the shop where you purchased the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>