- Determine the exact vertical location for proper alignment with the door latch bolt.
- Disassemble the bracket and align the L-shaped bracket with the edge of the door jamb.
- Attach the bracket using the provided screws for horizontal adjustment.
- Thread the strike wiring through the bracket wiring hole and mount the strike using the included bolts and washers.
- Test and adjust the bracket position for proper door operation.
- Drill a wiring outlet hole and connect the wiring as per the strike’s manual.
- Fix the strike in place with self-tapping screws after testing positioning.
- Reinstall the rim strike cover and attach end plates.
- Test the door and strike for proper operation.
FAQ
- Q: What is the purpose of the horizontal adjustment holes in the bracket?
- A: The horizontal adjustment holes allow for fine adjustments to ensure proper alignment and operation of the rim strike with the door latch bolt.
- Q: Do I need any additional tools for installation?
- A: The product comes with all the necessary tools and hardware required for installation, including a hex wrench for assembly.
- Q: Is it necessary to follow the specified dimensions during installation?
- A: Yes, following the specified dimensions is crucial to ensure proper fit and functionality of the surface-mount bracket with SECO-LARM rim strikes.
Specifications
- Material: Aluminum
- Dimensions: 111/16″x9x17/8″ (42.2×228.5×48.2 mm)
- Weight: 11.3-oz (320g)
Parts List
- 1x Surface-mount bracket
- 2x Strike mounting screws
- 2x End cap screws
- 1x Hex wrench
- 8x Bracket mounting wood screws
- 2x Strike mounting bolts
- 2x Split washers
- 1x Manual
Overview
Installation
- Determine the exact vertical location so that the rim strike will properly align with the door latch bolt.
- Disassemble the bracket and align the L-shaped bracket with the edge of the door jamb (or other mounting location). Use the 2 bracket mounting screws to attach it through the oblong holes on each end (Fig. 1). The holes are designed to allow the bracket up to 5/16″ (8mm) of horizontal adjustment (Fig. 2).
- Remove the rim strike cover. Thread the strike wiring through the bracket wiring hole and mount to the bracket using the included mounting bolts and washers through the oblong holes at each end of the strike (Fig. 3). These holes allow the strike up to 1/8″ (3.5mm) horizontal adjustment (Fig. 4).
- Test and confirm that the bracket position allows for proper door closing and locking/unlocking and adjust as needed. When correct, fix the location with the remaining 6 bracket mounting screws (Fig. 5).
- Drill a 1/4″ (6mm) wiring outlet hole (Fig. 6). Connect the wiring as described in the strike’s manual.
- Test and confirm the strike’s positioning and fix it in place with the 2 provided self-tapping strike mounting screws (Fig. 7). You may need to first drill a pilot hole.
- Reinstall the rim strike cover (Fig. 8).
- Attach the brackets cover and 2 end plates with their attachment screws (Fig. 9).
- Test the door and strike for proper operation.
California Proposition 65 Warning
- These products may contain chemicals that are known to the State of California to cause cancer and birth defects or other reproductive harm.
- For more information, go to www.P65Warnings.ca.gov.
WARRANTY
- This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer.
- SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
- This Warranty is void if the damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason, SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
- The sole obligation of SECO-LARM and the purchaser’s exclusive remedy shall be limited to the replacement or repair only, at SECO-LARM’s option.
- In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and
improvement. For that reason, SECO-LARM reserves the right to change
specifications without notice.
SECO-LARM is also not responsible for misprints. All trademarks are the
property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright ©
2024 SECO-LARM U.S.A., Inc. All rights reserved.
CONTACT
SECO-LARM ® U.S.A., Inc.
- 16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
- Phone: 949-261-2999 | 800-662-0800 Email: sales@seco-larm.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>