eurolite LED STP-15 QCL Bar User Manual

June 10, 2024
eurolite

eurolite LOGO LED STP-15 QCL Bar
User Manualeurolite LED STP 15 QCL Bar

LED STP-15 QCL Bar

This user manual is valid for the article number: 42103494
You can find the latest update of this user manual in the Internet under: www.eurolite.de

DANGER! Electric shock caused by short-circuit
Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires. Never open the housing. Keep the device away from rain and moisture.
Please read these instructions carefully before using the product. They contain important information for the correct use of the product.
Every person involved with the installation, operation and maintenance of this device has to

  • be qualified
  • follow the instructions of this manual
  • consider this manual to be part of the total product
  • keep this manual for the entire service life of the product
  • pass this manual on to every further owner or user of the product
  • download the latest version of the user manual from the Internet

INTRODUCTION

Thank you for having chosen one of our products. If you follow the instructions given in this manual, we are sure that you will enjoy this device for a long period of time. Product features
3in1 LED bar with RGBW beam effects, color animations and stroboscope

  • Stepless color blend, running light, preset colors, dimmer and strobe effect
  • Background color macros distributed in segments can be set via DMX
  • Electronic dimmer
  • Mains input and output for power linking up to 8 units
  • 14 powerful LEDs 5 W high-power 4in1 QCL RGBW (homogenous color mix)
  • 120 powerful LEDs SMD 5050 3in1 TCL RGB (homogenous color mix)
  • 180 powerful LEDs SMD 5730 cold white (CW)
  • 7 integrated show programs
  • Direct color selection for 42 or 38 preset colors
  • Can be operated in 9; 11; 17; 19 CH mode
  • The device is cooled by passive convection cooling
  • Controlling by stand-alone; Sound to light via Microphone; Master/slave function; DMX
  • Flicker-free
  • With a beam angle of 10° (5 W QCL LEDs)
  • With a beam angle of 120° (SMD LEDs)
  • 2 x mounting bracket
  • 4 digit 7-segment LED display for easy controlling

SAFETY INSTRUCTIONS

WARNING!
Please read the safety warnings carefully and only use the product as describe in this manual to avoid accidental injury or damage.
Intended use

  • This device is an LED bar for creating decorative lighting effects. This device is designed for professional use in the field of event technology, e.g. on stage. It is not suitable for household lighting.
  • Only use the device according to the instructions given herein. Damages due to failure to follow these operating instructions will void the warranty! We do not assume any liability for any resulting damage.
  • We do not assume any liability for material and personal damage caused by improper use or noncompliance with the safety instructions. In such cases, the warranty/guarantee will be null and void.
  • Unauthorized rebuilds or modifications of the device are not permitted for reasons of safety and render the warranty invalid.

Danger due to electricity

  • The device is suitable for indoor use only. Do not use it outdoors. Never expose it to rain or moisture. Do not store it in rooms exposed to moisture.
  • To reduce the risk of electric shock, do not open any part of the device. There are no serviceable parts inside the device.
  • Only connect the device to a properly installed mains outlet. The outlet must be protected by residual current breaker (RCD). The voltage and frequency must exactly be the same as stated on the device. If the mains cable is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. Never defeat the protective ground of a mains cable. Failure to do so could result in damage to the device and possibly injure the user.
  • The mains outlet must be easily accessible so that you can unplug the device quickly if need be.
  • Never touch the mains plug with wet or damp hands. There is the risk of potentially fatal electric shock.
  • The mains cable must not be bent or squeezed. Keep it away from hot surfaces or sharp edges.
  • Never pull the mains cable to disconnect the mains plug from the mains outlet, always seize the plug.
  • Unplug the device during lightning storms, when unused for long periods of time or before cleaning.
  • Do not expose the device to any high temperatures, direct sunlight, dripping or splashing water, strong vibrations or heavy mechanical stress.
  • Do not place any objects filled with liquids on the device.
  • Do not place any open sources of fire, such as burning candles, on or directly next to the device.
  • Make sure that objects cannot fall into the device, in particular metal parts.
  • Only have repairs to the device or its mains cable carried out by qualified service personnel. Repairs are required when the device or the mains cable is visibly damaged, liquid has been spilled or objects have fallen into the device; when the device has been exposed to rain or moisture, has been dropped or malfunctions occur.
  • Cleaning of the device is limited to the surface. Make sure that moisture does not come into contact with any areas of the terminal connections or mains voltage control parts. Only wipe off the product with a soft lint-free and moistened cloth. Never use solvents or aggressive detergents.

Danger to children and people with restricted abilities

  • This product is not a toy. Keep it out of the reach of children and pets. Do not leave packaging material lying around carelessly. Never leave this device running unattended.
  • This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.

Warning – risk of burns and fire

  • The admissible ambient temperature range (Ta) is -5 to +45°C. Do not operate the device outside of this temperature range.
  • The housing temperature (Tc) can be up to 55°C during use. Avoid contact by persons and materials.
  • Do not illuminate surfaces within 10 cm of the device. This value is indicated on the device by the symbol.
  • Do not use the device near highly flammable materials. Always place the device at a location where sufficient air circulation is ensured. Leave 50 cm of free space around the device. Never cover the air vents of the housing.

Warning – risk of injuries

  • Do not look directly at the light source. Persons with light-sensitive epilepsy may suffer from epileptic seizures or fall unconscious.

  • Make sure that the product is set up or installed safely and expertly and prevented from falling down.
    Comply with the standards and rules that apply in your country, in particular EN 60598-2-17.

  • If you lack the qualification, do not attempt the installation yourself, but instead use a professional installer.
    Improper installation can result in bodily injury and or damage to property.

  • The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety precautions.

  • For overhead use, always secure the device with a secondary safety attachment such as a safety bond or safety net.

  • Make sure that the area below the installation place is blocked when rigging, derigging or servicing the device.

  • For commercial use the country-specific accident prevention regulations of the government safety organization for electrical facilities must be complied with at all times.

Caution – material damage

  • This device must not be connected to the mains voltage by means of a dimmer.
  • Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.
  • Never switch the device on and off in short intervals. This will considerably reduce the service life of the device.
  • If the device has been exposed to drastic temperature fluctuation, do not switch it on immediately. The resulting condensation may destroy the device. Allow the device to reach room temperature before connecting it. Wait until the condensation has evaporated.
  • Please use the original packaging to protect the device against vibration, dust and moisture during transportation or storage.
  • If a serial number label is affixed to the device, do not remove the label as this would make the guarantee void.

DESCRIPTION OF THE DEVICE

eurolite LED STP 15 QCL Bar - DESCRIPTIONeurolite
LED STP 15 QCL Bar - DESCRIPTION 2

  1. 4in1 RGBW LEDs for beam effects
  2. RGB LEDs for color animations
  3. Cold white LEDs for strobe effects
  4. Safety eyelet
  5. DMX input
  6. Power input
  7. Display with operating buttons
  8. DMX output
  9. Power output
  10. Fixation screw
  11. Mounting bracket

INSTALLATION

WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing down. Make sure that the device is installed securely and cannot fall down. The installation must be carried out by a specialist who is familiar with the hazards and the relevant regulations.
The device may be fastened to a truss or similar rigging structure. The device must never be fixed swinging freely in the room.

  1. The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
  2. Block access below the work area and work from a stable platform when installing the device.
  3. Use rigging hardware that is compatible with the structure and capable of bearing the weight of the device. Please refer to the “Accessories” section for a list of suitable rigging hardware.
  4. Secure the device with a safety bond or other secondary attachment. This secondary safety attachment must be sufficiently dimensioned in accordance with the latest industrial safety regulations and constructed in a way that no part of the installation can fall down if the main attachment fails. Appropriate eyelets are mounted on the device for fixation of the safety bond. Fasten the safety bond in such a way that, in the event of a fall, the maximum drop distance of the device will not exceed 20 cm.
  5. To align the device, release the fixation screws at the two mounting brackets, adjust the desired inclination angle and retighten the fixation screws.
  6. After installation, the device requires inspections periodically to prevent the possibility of rot, deformation and looseness.

Attachment
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
The device must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum load and the building material.
Procedure:

Step 1: The holes for the installation are on the mounting brackets.
Step 2: Hold the mounting brackets onto the location where the device is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes.
Step 5: Hold the mounting brackets in the desired position and tighten it.

To align the device, release the fixation screws at the two mounting brackets, adjust the desired inclination angle and retighten the fixation screws

CONNECTIONS

DMX512 control
A DMX512 data link is required in order to control the device via DMX. The device provides 3-pin XLR connectors for DMX connection.

  1. Connect the output of your DMX controller to the DMX input DMX IN of the device with a DMX cable.
  2. Connect the DMX output DMX OUT of the device to the DMX input of the next unit in the chain. Always connect one output to the input of the next unit until all units are connected.
  3. At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between Signal (–) and Signal (+) in the DMX output of the last unit.
  4. If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended to insert a DMX level amplifier to ensure proper data transmission.

XLR connection:

eurolite LED STP 15 QCL Bar - XLR connection

Connection to the mains
The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.

  1. The device is equipped with a lockable power input connector. Fix the mains cable and turn it to the right until it locks. Connect the device via the mains cable to a grounded mains socket. Thus the unit is switched on.
  2. To switch off the unit, disconnect the power plug.
  3. Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains outlet which is switchable.

Power supply of further devices
The jack POWER OUT allows for power supply of further devices. To interconnect several devices, connect the jack POWER OUT to the input POWER IN of the next unit until all units are connected. Matching power cables with P-Con plugs are available as accessories. In this manner, up to 8 devices can be linked at 230/240 input voltage and up to 4 devices at 110/115 input voltage.

OPERATION

After connecting the device to the mains it is ready for operation. The display indicates the last operating mode. The operating modes can be selected by means of the display and the control buttons. All settings remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone mode via the control board or in DMX-controlled mode via any commercial DMX controller.
Menu structure
Press the MENU button so many times until the desired function is indicated on the display. Use the ENTER button to select the function. With the buttons UP and DOWN you can select the mode. Confirm with ENTER.

Mode Display Function
Automatic mode Auto Sp 1-10

Program running speed 1-10 slow > fast
St 0-9| Strobe effect 0-9 slow > fast
DMX mode| Addr| 19H| d001- 494| 19-channel mode and starting address
17CH| d001- 496| 17-channel mode and starting address
11CH| d001- 502| 11-channel mode and starting address
9CH| d001- 504| 9-channel mode and starting address
Show program mode| Shou| Sh 1-7| Show program 1-7
Sp 1-10| Program running speed 1-10 slow > fast
St 0-9| Strobe effect 0-9 slow > fast
Sound control| Soud| Sou 1-2| Show program 1-2
Sen 1-9| Microphone sensitivity low > high
Slave mode| SLAV| Slave| Slave mode
Individual color mix| Colo| r000-255| Red Intensity 0 – 100%
g000-255| Green Intensity 0 – 100%
b000-255| Blue Intensity 0 – 100%
U000-255| White Intensity 0 – 100%
St 0-9| Strobe effect 0-9 slow > fast
Preset colors| StAt| CL01-CL42 / RGBW-LEDs| Constant lighting in one of 42 colors
CC01-CC38 / RGB-LEDs| Constant lighting in one of 38 colors
St 0-9| Strobe effect 0-9 slow > fast
Product Set (System settings)| Set| dis| 10S| Display deactivation
Off after XX seconds
20S
30S
60S
on
temp| 50°~65°C| Setting the maximum inner temperature
When the inner temperature reaches the set value, the device gradually reduces the power
dir| | Direction of internal programs “Shou“ and “Soud“ from left to right
| Direction of internal programs ”Shou“ and “Soud“ from right to left
Send| Yes| The selected/desired DMX channel mode is transmitted to further devices in the chain
Send
Information| Info| Ver| xxxx| Software version
---|---|---|---|---
temp| xxC| Current inner temperature (°C)

Stand-alone mode
Automatic mode
In Automatic mode, the internal programs run randomly at an adjustable speed.

  1. Press the MENU button so many times until Auto is indicated in the display. Confirm with the ENTER button.
  2. Use the buttons UP and DOWN to adjust the desired running speed of the program from SP 1 (slow) to SP 10 (fast). Confirm with the ENTER button.
  3. The setting of the strobe effect is the final menu item. Use the buttons UP and DOWN to select the desired flash frequency from St 1 (slow) to St 9 (fast). When set to St 0, the strobe effect is disabled.
    Confirm with the ENTER button.

Showprogram mode
In Showprogram mode, 7 show programs are available that run at an adjustable speed.

  1. Press the MENU button so many times until Shou is indicated in the display. Confirm with the ENTER button. Use the buttons UP and DOWN to select the desired show program Sh 1-7. Confirm with the ENTER button.
  2. Use the buttons UP and DOWN to adjust the running speed of the program from SP 1 (slow) to SP 9 (fast). Confirm with the ENTER button.
  3. The setting of the strobe effect is the final menu item. Use the buttons UP and DOWN to select the desired flash frequency from St 1 (slow) to St 9 (fast). When set to St 0, the strobe effect is disabled.
    Confirm with the ENTER button.

Sound control
Via the integrated microphone the unit can perfectly reproduce the show programs to the rhythm of the music (sufficient bass provided).

  1. Press the MENU button so many times until Soud is indicated in the display. Confirm with the ENTER button. Use the buttons UP and DOWN to select the desired show program Sou 1 or Sou 2. Confirm with the ENTER button.
  2. Use the buttons UP and DOWN to adjust the microphone sensitivity to the volume of the music (Sen 1 = low, Sen 9 = high). Confirm with the ENTER button.

Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled with the master unit without the need for a DMX controller. The devices must be set to the corresponding operating modes.

  1. Configure all slave units before connecting the master unit: Press the MENU button so many times until SLAV is indicated in the display. Confirm with the ENTER button.
  2. Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller to the DMX input of the master unit.
  3. Set the master unit to the desired operating mode. The interconnected devices will now operate synchronously.

Individual color mix
In the mode Colo each LED color can be individually adjusted for intensity. The device will constantly emit the adjusted color.

  1. Press the MENU so many times until Colo is indicated in the display. Confirm with the ENTER button.
  2. Now the display indicates the letter r for the color red and the corresponding intensity value. Use the buttons UP and DOWN to adjust the desired intensity. Confirm with the ENTER button. Now the color green can be adjusted; then blue and white.
  3. The setting of the strobe effect for the white LEDs is the final menu item. Use the buttons UP and DOWN to select the desired flash frequency from St 1 (slow) to St 9 (fast). When set to St 0, the strobe effect is disabled. Confirm with the ENTER button.

Preset colors
In the StAt mode, the device will constantly emit one of the individually preset colors.

  1. Press the MENU button so many times until StAt is indicated in the display. Confirm with the ENTER button.
  2. Use the buttons UP and DOWN to adjust the desired color of the RGBW LEDs CL 01-41. When CL 42 is selected, the LEDs are switched off. Confirm with the ENTER button.
  3. Then use the buttons UP and DOWN to adjust the desired color of the RGB LEDs CC 01-38. When CC 38 is selected, the LEDs are switched off. Confirm with the ENTER button.
  4. The setting of the strobe effect is the final menu item. Use the buttons UP and DOWN to select the desired flash frequency from St 1 (slow) to St 9 (fast). When set to St 0, the strobe effect is disabled.
    Confirm with the ENTER button.

Product Set (System settings)
The menu point Product Set allows the possibility to adjust further settings.

  1. Call up the point Set in the menu.
  2. Navigate to the desired setting.
  3. Under dis, you can set the desired display activation time. In the temp menu you can set the desired maximum inner temperature setting. In dir mode you can set the running direction for the internal programs “Shou“ and ”Soud“. Under Send, you can transmit the desired DMX channel mode to all connected devices in the chain. Always confirm with the ENTER button.

Information
The display can indicate the software version as well as the current operating temperature of the device.

  1. Press the MENU button so many times until Info is indicated in the display. Confirm with the ENTER button. The display indicates Ver.
  2. Confirm again with the ENTER button. Now the display shows the current software version.
  3. Under temp the display shows, after confirming with ENTER, the current inner temperature in degrees Celsius of the device.

DMX operation
Setting the number of DMX channels and the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped with 19 control channels. However, it can also be switched to a mode with 9, 11 or 17 channels if different functions are required. To be able to operate the device with a DMX controller, the DMX starting address must be set. The starting address depends upon which DMX controller is being used. Please refer to the controller’s documentation.

  1. Press the MENU button so many times until Addr is indicated in the display. Confirm with the ENTER button.

  2. The display indicates 9 CH (9 DMX channels), 11 CH (11 DMX channels), 17 CH (17 DMX channels) or 19 CH (19 DMX channels). Use the buttons UP and DOWN to select the desired DMX channel mode.
    Confirm with the ENTER button.

  3. Now the display indicates the menu item for the DMX start address A***. Use the buttons UP and DOWN to set the address. Confirm with the ENTER button.

  4. DMX is indicated when the last segment in the display blinks.

Note: Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX chain. If several devices are addressed to the same address, they will work synchronously.
The LEDs of the device are divided into 5 segments, which as background color macros can be set in the 19 channel mode with the following DMX protocol.

eurolite LED STP 15 QCL Bar - DMX protocol

Functions in DMX mode
9-channel mode

Channel Value Function
1 000 – 255 Red 0 – 100%
2 000 – 255 Green 0 – 100%
3 000 – 255 Blue 0 – 100%
4 000 – 255 White 0 – 100%
5 000 – 255 Red 0 – 100%
6 000 – 255 Green 0 – 100%
7 000 – 255 Blue 0 – 100%
8 000 – 255 White SMD 0 – 100%
9 000 – 009 No function
010 – 255 Strobe effect (White SMD) with increasing speed

11-channel mode

Channel Value Function
1 000 – 255 Red 0 – 100%
2 000 – 255 Green 0 – 100%
3 000 – 255 Blue 0 – 100%
4 000 – 255 White 0 – 100%
5 000 – 009 No function
010 – 255 Strobe effect ( RGBW LED ) with increasing speed
6 000 – 255 Red 0 – 100%
7 000 – 255 Green 0 – 100%
8 000 – 255 Blue 0 – 100%
9 000 – 009 No function
010 – 255 Strobe effect ( RGB LED ) with increasing speed
10 000 – 255 White SMD 0 – 100%
11 000 – 009 No function
010 – 255 Strobe effect ( White SMD ) with increasing speed

17-channel mode

Channel Value Function
1 000 – 255 Red 0 – 100%
2 000 – 255 Green 0 – 100%
3 000 – 255 Blue 0 – 100%
4 000 – 255 White 0 – 100%
5 000 – 009 No function
010 – 255 Strobe effect ( RGBW LED ) with increasing speed
6 000 – 004 No function
005 – 009 Program 1 **Color choice via CH 1 ~ 4

or
Internal program, if CH 1 ~ 4 all on “000”
010 – 014| Program 2
015 – 019| Program 3
020 – 024| Program 4
025 – 029| Program 5
| 030 – 034| Program 6|
---|---|---|---
035 – 039| Program 7
040 – 044| Program 8
045 – 049| Program 9
050 – 054| Program 10
055 – 059| Program 11
060 – 064| Program 12
065 – 069| Program 13
070 – 074| Program 14
075 – 079| Program 15
080 – 084| Program 16
085 – 089| Program 17
090 – 094| Program 18
095 – 099| Program 19
100 – 104| Program 20
105 – 109| Program 21
110 – 114| Program 22
115 – 119| Program 23
120 – 124| Program 24
125 – 129| Program 25
130 – 134| Program 26
135 – 139| Program 27
140 – 144| Program 28
145 – 149| Program 29
150 – 154| Program 30
155 – 159| Program 31
160 – 164| Program 32
165 – 169| Program 33
170 – 174| Program 34
175 – 179| Program 35
180 – 184| Program 36
185 – 189| Program 37
190 – 194| Program 38
195 – 199| Program 39
200 – 204| Program 40
205 – 209| Program 41
210 – 214| Program 42
215 – 219| Program 43
220 – 224| Program 44
225 – 229| Program 45
230 – 255| Programs 1 ~ 45 in continuous loop
7| 000 – 255| Speed ( RGBW LED programs ), increasing
8| 000 – 255| Red 0 – 100%| 3in1 RGB LEDs
9| 000 – 255| Green 0 – 100%
10| 000 – 255| Blue 0 – 100%
11| 000 – 009| No function
010 – 255| Strobe effect (
RGB LED ) with increasing speed
12| 000 – 009| No function
010 – 019| Program 1|
Color choice via CH 8 ~ 10
| 020 – 029| Program 2| or
Internal program, if CH 8 ~ 10 all on “000”
---|---|---|---
030 – 039| Program 3
040 – 049| Program 4
050 – 059| Program 5
060 – 069| Program 6
070 – 079| Program 7
080 – 089| Program 8
090 – 099| Program 9
100 – 109| Program 10
110 – 119| Program 11
120 – 129| Program 12
130 – 139| Program 13
140 – 149| Program 14
150 – 159| Program 15
160 – 169| Program 16
170 – 179| Program 17
180 – 189| Program 18
190 – 199| Program 19
200 – 209| Program 20
210 – 219| Program 21
220 – 229| Program 22
230 – 239| Program 23
240 – 249| Program 24
250 – 255| Programs 1 ~ 24 in continuous loop
13| 000 – 255| Speed ( RGB LED programs ), increasing
14| 000 – 255| White SMD 0 – 100%
15| 000 – 009| No function
010 – 255| Strobe effect (
White SMD ) with increasing speed
16| 000 – 013| No function
014 – 027| Program 1
028 – 041| Program 2
042 – 055| Program 3
056 – 069| Program 4
070 – 083| Program 5
084 – 097| Program 6
098 – 111| Program 7
112 – 125| Program 8
126 – 139| Program 9
140 – 153| Program 10
154 – 167| Program 11
168 – 181| Program 12
182 – 195| Program 13
196 – 209| Program 14
210 – 223| Program 15
224 – 237| Program 16
238 – 251| Program 17
252 – 255| Programs 1 ~ 17 in continuous loop
17| 000 – 255| Speed ( White SMD programs** ), increasing

19-channel mode

Channel Value Function
1 000 – 255 Red 0 – 100%
2 000 – 255 Green 0 – 100%
3 000 – 255 Blue 0 – 100%
4 000 – 255 White 0 – 100%
5 000 – 009 No function
010 – 255 Strobe effect ( RGBW LED ) with increasing speed
6 000 – 004 No function
005 – 009 Program 1 **Color choice via CH 1 ~ 4

or
Internal program, if CH 1 ~ 4 all on “000”
010 – 014| Program 2
015 – 019| Program 3
020 – 024| Program 4
025 – 029| Program 5
030 – 034| Program 6
035 – 039| Program 7
040 – 044| Program 8
045 – 049| Program 9
050 – 054| Program 10
055 – 059| Program 11
060 – 064| Program 12
065 – 069| Program 13
070 – 074| Program 14
075 – 079| Program 15
080 – 084| Program 16
085 – 089| Program 17
090 – 094| Program 18
095 – 099| Program 19
100 – 104| Program 20
105 – 109| Program 21
110 – 114| Program 22
115 – 119| Program 23
120 – 124| Program 24
125 – 129| Program 25
130 – 134| Program 26
135 – 139| Program 27
140 – 144| Program 28
145 – 149| Program 29
150 – 154| Program 30
155 – 159| Program 31
160 – 164| Program 32
165 – 169| Program 33
170 – 174| Program 34
175 – 179| Program 35
180 – 184| Program 36
185 – 189| Program 37
190 – 194| Program 38
195 – 199| Program 39
200 – 204| Program 40
| 205 – 209| Program 41
---|---|---
210 – 214| Program 42
215 – 219| Program 43
220 – 224| Program 44
225 – 229| Program 45
230 – 255| Programs 1 ~ 45 in continuous loop
7| 000 – 255| Speed ( RGBW LED programs ), increasing
8| 000 – 255| Background color macros
Color choice via RGBW Static Color Table for programs 1 ~ 23
9| 000 – 255| Red 0 – 100%| 3in1 RGB LEDs
10| 000 – 255| Green 0 – 100%
11| 000 – 255| Blue 0 – 100%
12| 000 – 009| No function
010 – 255| Strobe effect (
RGB LED ) with increasing speed
13| 000 – 009| No function
010 – 019| Program 1|
Color choice via CH 9 ~ 11
or
Internal program, if CH 9 ~ 11 all on “000”
020 – 029| Program 2
030 – 039| Program 3
040 – 049| Program 4
050 – 059| Program 5
060 – 069| Program 6
070 – 079| Program 7
080 – 089| Program 8
090 – 099| Program 9
100 – 109| Program 10
110 – 119| Program 11
120 – 129| Program 12
130 – 139| Program 13
140 – 149| Program 14
150 – 159| Program 15
160 – 169| Program 16
170 – 179| Program 17
180 – 189| Program 18
190 – 199| Program 19
200 – 209| Program 20
210 – 219| Program 21
220 – 229| Program 22
230 – 239| Program 23
240 – 249| Program 24
250 – 255| Programs 1 ~ 24 in continuous loop
14| 000 – 255| Speed ( RGB LED programs ), increasing
15| 000 – 255| Background color macros
Color choice via RGB Static Color Table for programs 1 ~ 11
16| 000 – 255| White SMD 0 – 100%
17| 000 – 009| No function
010 – 255| Strobe effect (
White SMD ) with increasing speed
18| 000 – 013| No function
014 – 027| Program 1
028 – 041| Program 2
| 042 – 055| Program 3
---|---|---
056 – 069| Program 4
070 – 083| Program 5
084 – 097| Program 6
098 – 111| Program 7
112 – 125| Program 8
126 – 139| Program 9
140 – 153| Program 10
154 – 167| Program 11
168 – 181| Program 12
182 – 195| Program 13
196 – 209| Program 14
210 – 223| Program 15
224 – 237| Program 16
238 – 251| Program 17
252 – 255| Programs 1 ~ 17 in continuous loop
19| 000 – 255| Speed ( White SMD programs** ), increasing

RGBW Static Color Table

Value Color Setting
0-4 R:000 G:000 B:000 W:000
5-9 R:051 G:000 B:000 W:000
10-14 R:102 G:000 B:000 W:000
15-19 R:153 G:000 B:000 W:000
20-24 R:204 G:000 B:000 W:000
25-29 R:255 G:000 B:000 W:000
30-34 R:000 G:051 B:000 W:000
35-39 R:000 G:102 B:000 W:000
40-44 R:000 G:153 B:000 W:000
45-49 R:000 G:204 B:000 W:000
50-54 R:000 G:255 B:000 W:000
55-59 R:000 G:000 B:051 W:000
60-64 R:000 G:000 B:102 W:000
65-69 R:000 G:000 B:153 W:000
70-74 R:000 G:000 B:204 W:000
75-79 R:000 G:000 B:255 W:000
80-84 R:000 G:000 B:000 W:051
85-89 R:000 G:000 B:000 W:102
90-94 R:000 G:000 B:000 W:153
95-99 R:000 G:000 B:000 W:204
100-104 R:000 G:000 B:000 W:255
105-109 R:051 G:051 B:000 W:000
110-114 R:102 G:102 B:000 W:000
115-119 R:153 G:153 B:000 W:000
120-124 R:204 G:204 B:000 W:000
125-129 R:255 G:255 B:000 W:000
130-134 R:051 G:000 B:051 W:000
135-139 R:102 G:000 B:102 W:000
140-144 R:153 G:000 B:153 W:000
145-149 R:204 G:000 B:204 W:000
150-154 R:255 G:000 B:255 W:000
155-159 R:000 G:051 B:051 W:000
160-164 R:000 G:102 B:102 W:000
165-169 R:000 G:153 B:153 W:000
170-174 R:000 G:204 B:204 W:000
175-179 R:000 G:255 B:255 W:000
180-184 R:051 G:000 B:000 W:051
185-189 R:102 G:000 B:000 W:102
190-194 R:153 G:000 B:000 W:153
195-199 R:204 G:000 B:000 W:204
200-204 R:255 G:000 B:000 W:255
205-209 R:000 G:051 B:000 W:051
210-214 R:000 G:102 B:000 W:102
215-219 R:000 G:153 B:000 W:153
220-224 R:000 G:204 B:000 W:204
225-229 R:000 G:255 B:000 W:255
230-234 R:000 G:000 B:051 W:051
235-239 R:000 G:000 B:102 W:102
240-244 R:000 G:000 B:153 W:153
245-249 R:000 G:000 B:204 W:204
250-255 R:000 G:000 B:255 W:255

5050-LED-RGB Static Color Table

Value Color Setting
0-6 R:000 G:000 B:000
7-13 R:051 G:000 B:000
14-20 R:102 G:000 B:000
21-27 R:153 G:000 B:000
28-34 R:204 G:000 B:000
35-43 R:255 G:000 B:000
42-48 R:000 G:051 B:000
49-55 R:000 G:102 B:000
56-62 R:000 G:153 B:000
63-69 R:000 G:204 B:000
70-76 R:000 G:255 B:000
77-83 R:000 G:000 B:051
84-90 R:000 G:000 B:102
91-97 R:000 G:000 B:153
98-104 R:000 G:000 B:204
105-111 R:000 G:000 B:255
112-118 R:051 G:051 B:000
119-125 R:102 G:102 B:000
126-132 R:153 G:153 B:000
133-139 R:204 G:204 B:000
140-146 R:255 G:255 B:000
147-153 R:051 G:000 B:051
154-160 R:102 G:000 B:102
161-167 R:153 G:000 B:153
168-174 R:204 G:000 B:204
175-181 R255 G:000 B:255
182-188 R:000 G:051 B:051
189-195 R:000 G:102 B:102
196-202 R:000 G:153 B:153
203-209 R:000 G:204 B:204
210-216 R:000 G:255 B:255
217-223 R:051 G:051 B:051
224-230 R:102 G:102 B:102
231-237 R:153 G:153 B:153
238-244 R:204 G:204 B:204
245-255 R:255 G:255 B:255

CLEANING AND MAINTENANCE

The outside of the device should be cleaned periodically to remove contaminants such as dust etc. The lenses, in particular, should be clean to ensure that light will be emitted at maximum brightness.

  1. Disconnect the device from power and allow it to cool before cleaning.
  2. Clean the surface with a soft lint-free and moistened cloth. Never use alcohol or solvents as these may damage the surface. Make sure that no liquids can enter the device.
  3. The device must be dry before reapplying power.

There are no serviceable parts inside. Do not open the housing. Do not try to repair the device by yourself as this may result in damage. Maintenance and service operations are only to be carried out by authorized dealers. Should you need any spare parts, please use genuine parts. Should you have further questions, please contact your dealer.

PROTECTING THE ENVIRONMENT

Disposal of old equipment
**** When to be definitively put out of operation, take the product to a local recycling plant for a disposal which is not harmful to the environment. Devices marked with this symbol must not be disposed of as household waste. Contact your retailer or local authorities for more information. Remove any inserted batteries and dispose of them separately from the product.
You as the end user are required by law (Battery Ordinance) to return all used batteries/ rechargeable batteries. Disposing of them in the household waste is prohibited. You may return your used batteries free of charge to collection points in your municipality and anywhere where batteries/rechargeable batteries are sold. By disposing of used devices and batteries correctly, you contribute to the protection of the environment.

TECHNICAL SPECIFICATIONS

Power supply: 100-240 V AC, 50/60 Hz
Power consumption: 120 W
IP classification: IP20
Protection class: Class I
Power connection: Mains input via P-Con (blue), mounting version Power supply

cord with safety plug (provided)
Power output:| P-Con (gray), mounting version
Lamp type:| LED lamp
LED:| 14 x 5 W high-power 4in1 QCL RGBW (homogenous color mix)
120 x SMD 5050 3in1 TCL RGB (homogenous color mix)
180 x SMD 5730 cold white (CW)
Flash rate:| 0 – 20 Hz
DMX channels:| 9; 11; 17; 19
DMX input:| 3-pin XLR (M) mounting version
DMX output:| 3-pin XLR (F) mounting version
Cooling:| Passive convection cooling
Control:| Stand-alone; Sound to light via Microphone; Master/slave function; DMX
Beam angle (1/2 peak):| Beam 10°
Ambient light 120°
Housing color:| Black
Attachment system:| 2x mounting bracket
Display type:| 4 digit 7-segment LED display
Dimensions:| Length: 1 m
Depth: 6.7 cm
Height: 12.0 cm
Weight:| 3.55 kg

Accessories

EUROLITE TPC-10 Coupler, silver No. 59006856
EUROLITE Safety Bond UNV-5 3x600mm up to 5kg silver No. 58010372
EUROLITE DMX cable XLR 3pin 3m black No. 3022785H
PSSO DMX cable XLR 3pin 3m black Neutrik No. 30227810
PSSO PowerCon Connection Cable 3×1.5 3m No. 3023503R
PSSO PowerCon Power Cable 3×1.5 1.5m H07RN-F No. 30235030

All information is subject to change without prior notice. © 10.10.2022

eurolite LOGOEurolite is a brand of Steinigke Showtechnic GmbH
Andreas-Bauer-Str. 5 97297 Waldbüttelbrunn Germany
D00142420 Version 1.0 Publ. 10/10/2022eurolite LED STP 15 QCL Bar -
ICOn 1

Documents / Resources

| eurolite LED STP-15 QCL Bar [pdf] User Manual
LED STP-15 QCL Bar, LED STP-15 QCL Bar, STP-15 QCL Bar, QCL Bar
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals