Product Specifications
Product | IFGS-1022TF |
---|
Hardware Specifications
Fast Ethernet Copper Ports| 8 x 10/100BASE-TX RJ45 auto-MDI/MDI-X ports
Gigabit Ethernet Copper Ports| 2 x 10/100/1000BASE-T RJ45 auto-MDI/ MDI-X
ports (shared with Port-9 and Port-10)
SFP Ports| 2 x 1000BASE-SX/LX/BX SFP interfaces (shared with Port-9 and
Port-10)
Enclosure| IP30 metal case
Installation| DIN-rail kit and wall-mount kit
Connector| Removable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
Alarm| One relay output for power failure. Alarm relay current carry ability:
1A @ 24V DC
Dimensions (W x D x H)| 50 x 87.8 x 135 mm
Weight| 536g
Power Requirements| Dual 9~48V DC, 24V AC
Power Consumption| Max. 7.2 watts/24.6BTU
ESD Protection| 6KV DC
Switching Specifications
Switch Architecture| Store-and-Forward
Switch Fabric| 5.6Gbps (non-blocking)
Throughput (packet per second)| 4.16Mpps@ 64 bytes
Address Table| 16K entries, automatic source address learning and aging
Shared Data Buffer| 4Mbits
Jumbo Frame| 10K bytes
Flow Control| IEEE 802.3x pause frame for full-duplex Back pressure for half-
duplex
Standards Conformance
Regulatory Compliance| FCC Part 15 Class A, CE
Stability Testing| IEC60068-2-32 (free fall)
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
Standards Compliance| IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000T
IEEE 802.3z Gigabit SX/LX
IEEE 802.3x flow control and back pressure
IEEE 802.1p Class of Service
IEEE 802.3az Energy Efficient Ethernet (EEE)
Environment
Operating Temperature| -40 ~ 75 degrees C
Storage Temperature| -40 ~ 85 degrees C
Humidity| 5 ~ 95% (non-condensing)
Hardware Introduction
3.1 Switch Front Panel
The front panel of the Industrial Ethernet Switch consists of Ethernet
interfaces and LED indicators.
▶ Front View
Figure 1: IFGS-1022TF Front View
3.2 LED Definition:
▶ System
LED | Color | Function |
---|---|---|
P1 | Green | Lights to indicate power input 1 has power. |
P2 | Green | Lights to indicate power input 2 has power. |
Alarm | Red | Lights: indicates either power 1 or power 2 has no power. |
▶ Per 10/100BASE-TX Port
LED | Color | Function |
---|---|---|
LNK/ACT | Green | Lights to indicate that the port is operating at 10/100Mbps. |
Blinking to indicate that the switch is actively sending or receiving data
over that port.
Off to indicate that the port is linked down.
▶ Per Gigabit RJ45 Combo Interface (Port-9~Port-10)
LED | Color | Function |
---|---|---|
LNK/ACT | Green | Lights to indicate the link through that port is successfully |
established.
Blinking to indicate that the switch is actively sending or receiving data
over that port.
Off to indicate that the port is linked down.
1000 Speed| Amber| Lights to indicate that the port is operating at 1000Mbps.
Off to indicate that the port is operating at 10/100Mbps.
▶ Per SFP Combo Interface (Port-9~Port-10)
LED | Color | Function |
---|---|---|
1000 LNK/ACT | Green | Lights to indicate that the port is operating at |
1000Mbps.
Blinking to indicate that the switch is actively sending or receiving data
over that port.
3.3 Switch Upper Panel
The upper panel of the Industrial Ethernet Switch consists of one terminal
block connector within two power input and one relay output.
Figure 2: IFGS-1022TF Top View
3.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial Ethernet
Switch is used for two redundant power inputs. Please follow the steps below
to insert the power wire.
When performing any of the procedures like inserting the wires or tightening
the wire-clamp screws, make sure the power is OFF to prevent from getting an
electric shock.
- Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or contacts 5 and 6 for POWER 2.
- Tighten the wire-clamp screws for preventing the wires from loosening.
Note
- The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
- The power input range is 9V ~ 48V DC and supports 24V AC
3.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as
the picture shows below. Inserting the wires, the Industrial Ethernet Switch
will detect the fault status of the power failure and then forms an open
circuit. The following illustration shows an application example for wiring
the fault alarm contacts.
Insert the wires into the fault alarm contacts
Note
- The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
- Alarm relay circuit accepts up to 24V DC, 1A.
Installation
This section describes the functionalities of the Industrial Ethernet Switch’s components and guides you to installing it on the DIN rail and wall. Please read this chapter completely before continuing.
Note
This following pictures show how to install the device.
However, the device in the picture is not IFGS-1022TF.
4.1 DIN-rail Mounting Installation
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting
4.4 Grounding the Device
User MUST complete grounding wired with the device; otherwise, a sudden
lightning could cause fatal damage to the device. EMD (Lightning) DAMAGE IS
NOT CONVERED UNDER WARRANTY.
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ
resource on PLANET web site first to check if it could solve your issue. If
you need more support information, please contact PLANET switch support team.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq
Switch support team mal address:
support@planet.com.tw
FCC Warning
This equipment has been tested and found to comply with the regulations for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with this user’s guide, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required
to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
WEEE Warning
**** To avoid the potential effects on the environment and human health as a
result of the presence of hazardous substances in electrical and electronic
equipment, end users of electrical and electronic equipment should understand
the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as
unsorted municipal waste and have to collect such WEEE separately.
Copyright © PLANET Technology Corp. 2021.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
PLANET Technology Corp.
10F., No. 96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Warning: This equipment is compliant with Class A of CISPR 32.
In a residential environment this equipment may cause radio interference.
2350-AH7070-000 www.PLANET.com.tw
Documents / Resources
|
PLANET IFGS-1022TF Industrial Ethernet
Switch
[pdf] User Manual
IFGS-1822TF, IFGS-1022TF, IFGS-1022TF Industrial Ethernet Switch, Industrial
Ethernet Switch, Switch, Ethernet Switch
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>