BenQ AR19_D WiT MindDuo e-Reading Lamp User Guide

June 10, 2024
BenQ

WiT MindDuo (AR19 _D)
e-Reading Lamp
User Guide

Package Contents

Check the packaging for the following items. If any is missing or damaged, please contact the place of purchase immediately.

  • WiT MindDuo lamp x 1
  • Pedestal base (or desk clamp) x 1
  • Power adapter x 1
  • Power cord x 1
  • The illustrations in this guide are for your reference only and may look different from the appearance of the actual product.
  • Actual accessories (e.g., pedestal base or desk clamp) included in the package will depend on the model you purchase. The desk clamp is also provided as separate purchase. Please contact your dealer for availability.

For Your Safety

  • Use only the supplied power adapter and connect only to suitable outlet power (100-240V AC, 50-60 Hz). Otherwise the lamp will fail to work normally or result in a fire hazard.
  • In order to prevent any damages to the lamp, do not hang or place any objects on the lamp.
  • Route the power cord so as to avoid it from being walked on or pinched by items placed upon or against it.
  • Place the lamp only on a solid, flat and stable surface. Otherwise the lamp may topple over and result in damages.
  • If the lamp will not be used for a long period of time, unplug it from the power outlet.
  • The light source contained in this luminaire can’t be replaced.

CAUTION

  • In case of the following situations, unplug the lamp from the power outlet immediately and contact the authorized service center or a qualified service person for inspection or repair:
    – When the outer casing of the lamp is broken
    – When there are strange odors coming from the lamp
    – When the LED light source flickers
    – When the insulation of the lamp’s wiring is damaged or frayed, and the metal strings inside can be seen

  • Do not use the lamp in a humid environment (like in a bathroom or outdoors).
    Otherwise the components inside may short-circuit and result in accidents.

  • This lamp is designed for indoor use only. Do not use it outdoors.

  • Never disassemble the lamp or remove any components from it, as doing so may result in accidents and will void the product warranty.

Installation

Pedestal Base

  1. Place the pedestal base on a solid, flat and stable surface.

  2. Insert the shaft on the pedestal base into the hole on the end of the lamp arm [Figure A 1 ] and then secure it by tightening the screw [Figure A 2 ].
    • Be sure to tighten the screw to secure the pedestal base to the lamp arm. Otherwise the pedestal base will detach from the lamp arm and result in damages or personal injuries if the lamp is unwittingly moved by grasping the lamp arm.
    • Use only the pedestal base supplied in the packaging to ensure that the lamp can stand firmly.

  3. Connect the power cord to the power input socket and power adapter [Figure A 3 ] and plug it into a power outlet [Figure A 4 ]. When the power is plugged, the lamp will automatically turn ON.

 Upon receiving power from the power outlet, the lamp’s built-in presence sensor will start to calibrate automatically, and the process will take approximately 1 minute. Please DO NOT turn off the lamp during the calibration process. You can start using the lamp when the calibration is complete.

BenQ AR19 D WiT MindDuo e Reading Lamp - Pedestal Base

Desk Clamp

  1. Place the desk clamp onto the edge of the desk surface [ Figure B 1 ] and then secure the desk clamp by tightening the clamp screw [ Figure B 2 ]. The maximum clampable thickness of the desk clamp is 6 cm.

  2. Insert the shaft on the desk clamp into the hole on the end of the lamp arm [ Figure B 3 ], and then secure it by tightening the screw [ Figure B 4 ].
    Be sure to tighten the screw to secure the desk clamp to the lamp arm.

  3. Connect the power cord to the power input socket and power adapter [ Figure B 5 ] and plug it into a power outlet [ Figure B 6 ]. When the power is plugged, the lamp will automatically turn ON.

Upon receiving power from the power outlet, the lamp’s built-in presence sensor will start to calibrate automatically, and the process will take approximately 1 minute.
Please DO NOT turn off the lamp during the calibration process. You can start using the lamp when the calibration is complete.

BenQ AR19 D WiT MindDuo e Reading Lamp - Desk Clamp

Using the Lamp

Turning On/Off the Lamp
To turn on or off the lamp, place your hand at least 2 cm under the on/off sensor [Figure C1, C2]. If the presence detection function is turned on, the lamp will turn on automatically when you enter the detection area. To turn off the lamp, place your hand at least 2 cm under the on/off sensor.

BenQ AR19 D WiT MindDuo e Reading Lamp - Lamp

Turning On/Off the Presence Detection Function
The presence detection function allows for the lamp to turn on automatically when you enter the detection area [ Figure D ].
To turn on the presence detection function, move the presence detection switch located on the lamp body to the ON position [ Figure E ]. To turn the function off, move the switch to the OFF position.

BenQ AR19 D WiT MindDuo e Reading Lamp - Presence Detection
Function

  • Do not block the presence sensor on the lamp. Otherwise the presence detection function will not work properly.
  • When the presence detection function is on, the lamp will turn off automatically to save power if you leave the detection area for 30 minutes.
  • With the presence detection function turned on, the lamp will automatically calibrate the Presence sensor when power is connected to the lamp or when the lamp is turned off. The calibration process takes approximately 40 seconds. During calibration, the Lighting mode indicator will light up green and orange alternately, and the presence detection function will be disabled temporarily.
  • To ensure normal operation of the presence detection function, please keep the lamp away from strong electromagnetic sources (like a Wi-Fi router).

Toggling Preset/Manual Lighting Modes
The lamp provides two preset lighting modes and one manual lighting mode that allows you to adjust the brightness and color temperature manually.

Lighting mode Setting Lighting mode indicator color
Color temperature Brightness level
Book reading 5700K Automatically optimized according to ambient lighting
condition Orange
Digital reading 4000K Green
Manual Adjustable Adjustable

BenQ AR19 D WiT MindDuo e Reading Lamp - Lighting
Modes

To toggle among lighting modes, press and hold the rotary knob on the lamp body for 2 seconds. The Lighting mode indicator lights up in the Book reading mode (orange) and Digital reading mode (green), and becomes off in the Manual mode.
In the Manual mode, you can manually adjust color temperature and brightness level using the rotary knob on the lamp body.

  1. Press the rotary knob to select the setting: the inner white circle on the rotary knob represents brightness level setting, and the outer color circle represents color temperature setting.
    When pressing the knob, be careful not to block the on/off sensor.BenQ AR19
D WiT MindDuo e Reading Lamp - knob

  2. Rotate the rotary knob to adjust the setting.
    BenQ AR19 D WiT MindDuo e Reading Lamp - Lighting Modes
2• Rotate the rotary knob clockwise to increase brightness level, or counter-clockwise to decrease it.
    • Rotate the rotary knob clockwise to increase color temperature (the light becomes whitish), or counter-clockwise to decrease it (the light becomes yellowish).

In the Manual mode, the lamp’s sensor detects the illuminance of the desktop and the Illuminance indicator on the rotary knob indicates the illuminance condition in three different colors:

  • Red: The illuminance condition is too dark. Please increase the lamp’s brightness level.
  • Green: The illuminance condition is good.
  • Blue: The illuminance condition is too bright. Please decrease the lamp’s brightness level.
  • When the lamp is turned off, the illuminance indicator will still light up in red, green or blue to indicate the illuminance condition of the desktop.
  • If the lamp is left on for 30 minutes, the Illuminance indicator will flash (in red, green or blue) to remind you that your eyes need a rest after a 30-minute reading.

USB Charging
The USB Type A port on the lamp arm provides 5V/0.5A (500mA) power supply to charge compatible mobile devices. Connect the device’s USB charging connector to the USB port to charge the device [ Figure F ].
The USB charging port is designed for charging compatible mobile devices only. Do NOT connect any external power supply to this port.

BenQ AR19 D WiT MindDuo e Reading Lamp - USB Charging

Adjusting Angle
You can adjust the angle of the lamp arm according to your desktop space to obtain a suitable lighting effect.

  • The lamp arm pivot is spring-loaded. Tighten the lamp arm pivot by turning the pivot knob clockwise [ Figure G ].
  • Refer to [ Figure H ] for the safe angle range of lamp arm adjustment.

BenQ AR19 D WiT MindDuo e Reading Lamp - USB Charging
2

Maintenance and Troubleshooting

  • Turn off the lamp first, and unplug the lamp from the power outlet. Wipe any smears or dusts off the lamp’s outer casing using a soft, lint-free cloth lightly moistened with a mild detergent solvent. Do not use alcohol or any other chemical solvents like kerosene, naphtha and so on, as the lamp’s casing may become damaged.
  • Do not rinse the lamp or any of its components directly with water.
  • If the lamp does not turn on, check to make sure that there are no loose connections between the power cord, power adapter, and the power outlet.
  • If the problem persists, please contact the original place of purchase for help.

Specifications

Model AR19 _D
DC power input 12V, 1.5A
USB DC output 5V, 0.5A
Max. power consumption 18W
Dimensions [ Figure I ] 345 x 395 x 480 mm (Width x Depth x Height)

BenQ AR19 D WiT MindDuo e Reading Lamp -
Specifications

**CE DOC

**

DECLARATION OF CONFORMITY
The device complies with the requirements set out in the Council Directives on the Approximation of the Laws of the Member States relating Electromagnetic Compatibility (2004/108/EC) and Low Voltage Directive (2006/95/EC) and Radio and Telecommunications Terminal Equipment Directive (1999/5/EC), the Restriction of The Use of Certain Hazardous Substances in Electrical And Electronic Equipment Directive (2011/65/EU), Turkish EEE Directive; Turkish ErP (Decision 2010/643);the Commission Regulation (EC) No 1275/2008 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to eco-design requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment, and the Commission Regulation (EC) No 1194/2012 implementing Directive 2009/125/EC of the European parliament and of the council establishing a framework for the setting of eco-design requirements for energy-related products.

FCC statement

Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

© 2020 BenQ Corporation.
All rights reserved.
Rights of modification reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BenQ User Manuals

Related Manuals