AcuityBrands EVO6PC GOTHAM Architectural Downlighting User Guide

June 10, 2024
AcuityBrands

AcuityBrands EVO6PC GOTHAM Architectural Downlighting User Guide

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

CAUTION RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

WARNING RISK OF BURN

  • Allow lamp/fixture to cool before handling.
    Do not touch enclosure or light source.

  • Do not exceed maximum wattage marked on luminaire label.

  • Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

CAUTION RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.

  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.

  • Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched circuit.

  • Unless individual product specifications deem otherwise:
    Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.

  • Unless individual product specifications deem otherwise:
    Do not exceed fixtures maximum ambient temperature.

  • Only use fixture in its intended location.

  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.

  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.

  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.

  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.

  • Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.

  • Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.

  • Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.

Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired operation

This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands| Indoor/Outdoor| Indoor Lighting| Outdoor Lighting| Controls| Daylighting
---|---|---|---|---|---
Lithonia Lighting| Aculux| American Electric Lighting| DARK TO LIGHT| SunOptics
Carandini| Gotham| Antique Street Lamps| LC&D
Holophane| Indy| Hydrel| ROAM
RELOCLight Concepts| Juno| Tersen| Sensor SwitchSynergy
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

These installation instructions are used for installing the following luminaires and kits.

Luminaire Variants Mounting Type Mounting Type Description
EVO4PC (4” Pendant Stem) ICO4PC (4” Pendant Stem) EVO6PC (6” Pendant Stem)
SGB Surface gear box, Recessed or surface J-box
SGBCC Surface gear box, Surface J-box with Conduit Covers

Identification of Pendant Mount Luminaires

Identification of Pendant Mount Luminaires

Identification of Parts

Stem Cylinder Assembly
Identification of Parts

Stem Hardware
a) Swivel ball
b) Screw (2)

  • 8-32 x 3/8” Lg. Pan Head

Canopy Assembly
a) SGB Canopy
b) SGBCC Canopy
Identification of Parts

Conduit Keys (SGBCC Only)
a) Blank Conduit Key (4) with 5/64” Allen wrench
b) Conduit Key (4) with 5/64” Allen wrench
Identification of Parts

Stem

Identification of Parts

a) External and internal threaded ends

  1. ICO4PC external threads: 1/4-18 NPSM
  2. EVO4PC external threads: 1/4-18 NPSM
  3. EVO6PC external threads: 3/8-18 NPSM

b) Internal threaded ends

  1. ICO4PC internal threads: 1/8-27 NPSM
  2. EVO4PC internal threads: 1/8-27 NPSM
  3. EVO6PC internal threads: 1/4-18 NPSM

c) Threaded nipple

Stem Length Calculation

  1. Calculate the necessary stem length per the equations below.
    ICO4/EVO4
    Stem Length = B – A – 13”
    EVO6
    Stem Length = B – A – 15”
    Stem Length Calculation

  2. If there are multiple sections of stem, assemble them together using the threaded nipples provided.
    Stem Length Calculation

  3. Cut the assembled stem to the calculated length per Step 1.
    Stem Length Calculation

Stem End Hole Drilling for Swivel Ball

  1. Locate the swivel ball and stem that has already been assembled and cut to length.
    End Hole Drilling for Swivel Ball

  2. Place swivel ball on the stem end opposite of the external threads.

  3. Make sure ball is seated on the top of the stem.
    Thread screws into eachside of the swivel ball to secure it in place before drilling.

  4. Using the guide holes in the ball and a drill with a 3/16” drill bit, drill through both sides of the stem.
    End Hole Drilling for Swivel Ball

  5. Loosen screws and remove swivel ball from stem for later assembly steps.
    Note: Swivel ball will be secured to the stem in a later step by tightening screws and engaging them into the holes that were drilled in the end of the stem.

Stem Cylinder Assembly

  1. Unscrew cap from cylinder. Align stem with the cylinder so the external threads of the stem are closest to the top of the cylinder. Pull the wires through the stem, then thread it into the cylinder. Leave at least 6” of wires coming out of the end of the stem.
    Note: Set screw may need to be loosened to allow threading in the stem.
    Cylinder Assembly

  2. Once the stem has been threaded in fully, tighten the set screw to lock the stem in the cylinder. Then screw on and hand tighten the cap.

Fixture Install

NOTE:

  • SGB mounting type fixtures require a 1.5” minimum depth, 4” octagonal junction box.
  • SGBCC mounting type fixtures require a 1.5” depth, 4” octagonal junction box.
  • Recessed junction boxes cannot be more than 1/8” proud of the ceiling surface.
  • WARNING: All pendant fixtures exposed to wind require tethering – consult factory
  1. Pull the canopy cover off the bottom of the assembly

  2. Unscrew the two screws and remove canopy from driver assembly. If SGB fixture, skip to Step 5.
    Fixture Install

  3. Select the appropriate keys and insert them into the correct canopy slots for each specific J-box configuration. Adjust set screws in the keys to allow the keys to slide in completely.
    Note: Keys accept ½” and ¾” EMT conduit ONLY. Conduit fittings may vary by manufacturer. If using ¾” set screw type fittings, the fitting may need to be rotated so that the set screw is off vertical for proper clearance with canopies
    Fixture Install

  4. Tighten set screws in key tabs to secure them in the canopy. 5/64” Allen wrench is provided.
    IMPORTANT: SCREWS MUST BE TIGHTENED TO MAINTAIN GROUND CONTINUITY.
    Fixture Install

  5. Loosen two screws and rotate swivel plate to remove from driver assembly.

  6. Bring driver assembly up to J-box and bring supply wires through bracket cutouts. Align J-box screws with center marks in keyhole slots and tighten. Adjust screws in the slots as necessary to align fixture.
    Fixture Install

  7. Slide Canopy Cover (1), Canopy (2), Swivel Plate (3), and Swivel Ball (4) onto pipe in below order.
    Note: Rest parts on top of cylinder during ceiling install. Minimum stem length is 1ft.

  8. Thread screws into swivel ball and align with drilled holes in stem. Tighten screws so they are engaged through the holes in the stem.
    Fixture Install

  9. Align swivel ball groove with swivel plate tab as it is brought up to be secured to the driver assembly.
    Fixture Install

  10. Bring fixture up to the driver assembly and secure screws in the key holes. Make all connections per the following wiring diagrams.
    Fixture Install
    EVO4PC 250-5000 LUMENS
    EVO6PC 250-5000 LUMENS: (5000 LUMENS excludes EDXB and ECOD drivers)
    Wiring Diagram
    EVO6PC 5000 LUMENS: (Includes ONLY EDXB and ECOD drivers)
    EVO6PC 6000-8000 LUMENS
    Wiring Diagram
    nTUNE (TUWH DALI, WDIM 0-10V, WDIM DALI, WDIM NLT)
    EVO4PC 750-3000 LUMENS
    EVO6PC 750-5000 LUMENS
    Wiring Diagram
    nTUNE (TUWH 0-10V)
    EVO4PC 750-3000 LUMENS
    EVO6PC 750-5000 LUMENS
    Wiring Diagram
    PLEASE SEE 912-00164-001 RGH Instruction.pdf WHEN USING RECESSED GEAR HOUSING(RGH) FIXTURES.

  11. Slide canopy over driver assembly and secure it using the two #8-32 x 3/8” Lg. pan head screws.
    Fixture Install

  12. Bring canopy cover up and snap into the bottom of canopy.
    Fixture Install

GOTHAM ARCHITECTURAL DOWNLIGHTING
P: 1-800-705-SERV (7378)
www.gothamlighting.com

CJ53532 Rev. D
© Acuity Brands Lighting, Inc. 2019
All Rights Reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AcuityBrands User Manuals

Related Manuals