E-XTEQ E-VLT Leak Detector User Guide

June 10, 2024
1-800-Innovations

E-XTEQ E-VLT Leak Detector

E-VLT Quick Start Guide

Safety Advisory / Warranty
Before using the E-VLT, please read and understand the safety advisory and warranty information provided in the user manual.

Good Practices and Safety Instructions
Please follow the good practices and safety instructions provided in the user manual to ensure safe and proper usage of the E-VLT.

Preamble
The E-VLT is a device designed for testing battery groups. It is important to perform a leak test before using the device.

Principle of Cycle
The E-VLT operates by cycling the battery group through a sequence of charge, discharge, and rest phases. This allows for accurate testing of the battery’s capacity and performance.

Your E-VLT
The E-VLT comes with a user interface that includes cycle keys for controlling the testing process. The main menu screen provides options for preparing a program, selecting a battery to test, and starting and stopping a cycle.

User Interface

Overview
The user interface provides access to various features and functions of the E-VLT. The main menu screen displays options for preparing a program, selecting a battery to test, and starting and stopping a cycle.

Keys
The cycle keys are used to control the testing process. The power key is used to turn the device on and off. Other keys are used for selecting options and adjusting settings.

Main Menu Screen
The main menu screen provides options for preparing a program, selecting a battery to test, and starting and stopping a cycle.

Preparing a Program
To prepare a program, navigate to the main menu screen and select the “Preparing a Program” option. Follow the prompts to set the desired program parameters.

Preparing Battery Groups Programs
To prepare battery groups programs, navigate to the main menu screen and select the “Preparing Battery Groups Programs” option. Follow the prompts to set the desired battery group parameters.

Selecting a Battery to Test
To select a battery to test, navigate to the main menu screen and select the “Selecting a Battery to Test” option. Follow the prompts to select the desired battery.

Starting and Stopping Cycle
To start a cycle, navigate to the main menu screen and select the “Starting and Stopping Cycle” option. Follow the prompts to begin the testing process. To stop a cycle, press the stop key.

User Adjustments

The E-VLT allows for user adjustments to program and battery parameters. Navigate to the configuration menu or results menu to make these adjustments.

ATEQ Manufacturer Plants – Measurement Solution, Global Leader.

| |
---|---|---
E-XTEQ 30, rue des Dames, Z.I. 78340 LES CLAYES-SOUS-BOIS FRANCE| e-xteq.com| Tél. : +33 1 30 07 1330

We continuously work on improving our products. This is why information contained in this man-ual, the device and the technical specifications may be modified without prior notification.
Pictures and figures in this manual are non-contractual.

Safety advisory / Warranty

GOOD PRACTICES AND SAFETY INSTRUCTIONS
Safety recommendations
The device is supplied with 100 / 240 V AC, it is mandatory to connect it to the ground with a good link to the ground, to protect against electric hazard or electrocution.

Recommendations for the test environment
Keep the test area as clean as possible.

Recommendations for operators
E-XTEQ recommends that the operators who use the devices have training and a level of qualification that correspond to the job to perform.
General recommendations

  • Read the user manual before using the device.
  • All electrical connections to the device must be equipped with safety systems (fuses, circuit breakers, etc.) adapted to the needs and in accordance with the applicable standards and rules.
  • To avoid electromagnetic interference, electrical connections to the device must be shorter than 2 meters.
  • Power supply plug must be grounded.
  • Disconnect the device from the mains before performing any maintenance work.
  • Shut off the compressed air supply when working on the pneumatic assembly.
  • Do not open a connected device.
  • Avoid splashing water on the device.

E-XTEQ is at your disposal for any information concerning the use of the device under maxi-mum safety conditions.
We draw your attention to the fact that E-XTEQ cannot be held responsible for any accident related to a misuse of the measuring instrument, the workstation or non-compliance of the in-stallation with safety rules.
In addition, E-XTEQ declines any responsibility for the calibration or the fitting of their instru-ments that is not done by E-XTEQ.
E-XTEQ also declines any responsibility for any modification (program, mechanical or electri-cal) of the device done without their written consent.

Preamble

E-VLT
E-VLT is a leak detector able to test large volume like EV battery housing and cooling.

3E-XTEQ-E-VLT-Leak-Detector-3

E-VLT can memorise 128 different test programs and 32 batteries sets of programs.

LEAK TEST
Leak test and Desenzitizes Mode

The test pressure is applied to the input of the test part 3.
The measurement is performed by the pressure sensor 2.

  1. Device
  2. Pressure sensor
  3. Part under test

Desensitized Mode: there is no leak fullscale. The limit is the test Pressure.

PRINCIPE OF CYCLE
The measurement cycle is made of 4 mains phases : fill, stabilization, test, dumping.

E-XTEQ-E-VLT-Leak-Detector-1

  • Waiting phase
  • Fill phase
  • Stabilization phase
  • Dumping

Your E-VLT

FRONT PANEL
The user interface is located on the front panel.

  1. Touchscreen Display
  2. USB Connectors

BACK PANEL

  1. Part number / Serial number
  2. Exhaust output
  3. Test part connector
  4. Calibration informations
  5. Connector for 100 / 240 V AC power supply

COUPLERS
Different couplers are mandatories to test Housing or cooling system. They must be connected on the test pipe fast connector..

POWER SUPPLY CONNECTORS
100 / 240 V AC connector (J7)
The device can be connected to a 100 / 240 V AC power supply (option).
This connector has a ON/OFF button.
It is mandatory to connect the device with a good link to the ground, to protect against electric hazard or electrocution.
Interruptor ON/OFF

DIGITAL LINKS
PC USB connectors (on front face)
USB connectors can be used for connecting miscellaneous compatible USB devices. The USB connectors are located under the rubber cover 1 (see figure).

  1. USB connector to PC
  2. USB connector to USB key or barcode reader
  3. Rubber cover

Do not use a cable longer than 2 m.
Push the rubber cover 3 slightly forward for an easy access to USB connectors 1 and 2.
Only use this connection for temporary communication.
Connection to a PC cannot be used permanently because the communication can be disconnected by the PC.

User interface

OVERVIEW

E-XTEQ-E-VLT-Leak-Detector-6

KEYS
Cycle keys
The cycle keys are used to start and to stop a measurement cycle.

Key Name Function
Start Starts a measurement cycle and opens the **Measuremen

cycle screen.
|
Reset**| Stops the measurement cycle in progress.

Keys
The navigation keys are used to select menus/options and change parameter values.

Key Name Function
OK Validation of actual screen.
Back Returns to previous screen.

POWER UP

  1. Make sure that all the necessary connections are in place.
  2. Power up your device

When Power up part under pressure must NOT be connected to the instrument. Then the instrument propose an autotest.

MAIN MENU screen
The MAIN MENU screen gives access to different sections for managing the device and the test parameters.

  1. Battery selection and test Menu
  2. Results Menu
  3. Instrument configuration

PREPARING A PROGRAM
Use this process to configure a new test program.
On the MAIN MENU screen :

  1. Select « Battery » Menu

  2. Select « Parameters » Menu (requires Expert Rights) The program list is displayed.

    • Home : returns to main menu
    • Group parameters (Batteries)
    • Programs parameters
    • Special cycles (Autozero, …)
    • Configuration
  3. Select the program number you want to edit.

  4. Modify parameters
    For more details refer to chapter :
    User Adjustment / Program parameters

  5. Press Home to come back to main menu

PREPARING A BATTERY GROUPS PROGRAMS

  1. Select « Battery » Menu

  2. Select the battery group you want to edit

  3. Modify parameters
    For more details refer to chapter :
    User Adjustment / Battery parameters

  4. Press HOME to come back to main menu

SELECTING A BATTERY TO TEST

  1. Select « Battery » Menu

  2. Select « Battery list » Menu

  3. Select the correct battery in the list

  4. Select TEST TYPE (Housing or Cooling) Prepare and connect the correct coupler

STARTING AND STOPPING CYCLE
When the expected program is selected.
Starting a measurement cycle

Press Start.
The cycle phases of program are successively displayed :
FILL
STABILISATION
TEST
DUMP
At the end of the test time, the result is display.

Measurement cycle screen
It displays the different values of the current test (or last one).

E-XTEQ-E-VLT-Leak-Detector-16

  1. Battery Name

  2. Step progress

  3. Battery type of test

  4. Cloud connection (Not available yet)

  5. User Right (Normal/Expert)

  6. Pressure or Leak measurement

  7. Cycle step (Fill, Stab, Test, Dump, Ready)

  8. Bargraph : Pressure according to target or leak according to reject level

  9. Result of the test (Pass, Fail, Alarm code)

  10. Countdown Bargraph

  11. Time remaining to finish test

  12. In the center :
    When ready ; Start key
    Duting cycle : Cycle step icon
    When cycle is finished : Result icon (PASS / FAIL / ALA)

  13. Quantity program executed / Total in « Auto chain » mode.

Stopping a cycle

  1. Press Stop to immediately stop the current measurement.

User adjustments

PROGRAM PARAMETERS
Use this menu to configure the measurement cycle associated to each test program.

Groups Parameters Descriptions
Name Text field to easily organise program (Ex: batteryName Hous- ing) Test

type: Leak per default
Timers| Waiting time| Time before starting the cycle
Fill Time| Necessary time to fill the battery at the pressure instruction As soon as the instruction is reached, the fill time is shortened
Stabilisation

time

| Necessary time to get a correct measurement during test time
Test time| Necesary time to get a representative measurement (20 Pa) of the part with a leak closed to reject level (ex. leak of 0.1 Pa/s, it is advised to have 180s test time)
Dump time| Time required to dump the part through the instrument, for housing (low pressure) couplers can be unplug to earn time
Pressure| Pressure unit| Select correct unit in the list
Set Fill| Pressure instruction (Target)
Min and Max pressure| At the end of filling time pressure needs to be between these 2 levels
Leak| Leak unit| Select correct unit in the list
Max reject| Level to declare part under test as FAIL
Std Patm and Temperature| Requested parameters when specific unit as sccm is used
Offset| Manual offset that can be subtracted to the leak measurement. It is a usefull parameter to shorten stabilisation time (Reserved to expert)
Volume| It’s a necessary coeficient to convert pressure decay (in Pa) to leak (in flow unit like ml/min)
Options| Filter time| Usefull function to limit external pertubation during test time with flow unit, this time max must be inferior to 0.5*Test time
Sign| Change the sign of the measurement, (vaccum test)
Leak search| If the part is declared as leaking, the instrument maintains the pressure at the end of the test to let the operator look for the leak.
The test must must be stopped manually

BATTERY PARAMETERS
Use this menu to name and affect Test Programs.

Parameters Descriptions
Name Displayed name in the battery list menu
Picture Displayed pictures in the battery list menu (Not available yet)
Test 1 Housing Program selected to make Housing TEST
Test 2 Cooling Program selected to make Cooling TEST

CONFIGURATION MENU
Use this menu to configure your E-VLT device.

Parameters Descriptions
Date Define correct Date and Time. it is important for results stored.
Job Mode Using this mode, the instrument requires to make housing and

cooling on a specific battery. At the end of the test a special file records the tests.
Autochain| This mode automatically makes the specified quantity of tests and gen- erates a dedicated result file.

RESULTS MENU
In this section you can observe the results of the last 50 cycles.

Connecte a USB memory stick and press the white key to transfer data from the instruments :

  • Key/SerialNumber/Campaign : all the measurement done with auto chaining mode
  • Key/SerialNumber/Results : all the measurement done
  • Key/SerialNumber/jobs/ : all the measurement done with Job mode

FCC Warning

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Specifications

CARACTERISTICS
Technical characteristics of the device.

Main characteristics :

Characteristics Values
Mass About 8,5 kg (18.7 lbs)
Electrical power supply 100 / 240 V AC  55 W – 50/60 Hz
Overvoltage category II
Air supply From -10 to 250 kPa
Pneumatic connections: Fast connector Staubi RBE 03
Operation temperature +5 °C to + 45 °C (+ 41 °F to 113 °F)
Storage temperature 0 °C to +60 °C (32 °F to 140 °F)
Operation altitude Up to 2000 m (6500 ft)
Relative humidity 80 % at 31 °C (87 °F) and 50 % at 40 °C (104 °F)

Dimensions (in millimeters) :

Documents / Resources

| E-XTEQ E-VLT Leak Detector [pdf] User Guide
2AK5Y-E-VLT, 2AK5YEVLT, CDF 7000, E-VLT Leak Detector, E-VLT, Leak Detector, Detector
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals