LIGHTOLIER IS-4 N LyteProfile 4-Inch Round LED Adaptable Lighting Instruction Manual

June 4, 2024
LIGHTOLIER

LIGHTOLIER IS-4 N LyteProfile 4-Inch Round LED Adaptable Lighting Instruction Manual
LIGHTOLIER IS-4 N LyteProfile 4-Inch Round LED Adaptable
Lighting

This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation.
To prevent electrical shock, turn off electricity at fuse box before proceeding. Allow fixture to cool before handling

Retain these instructions for maintenance reference

Installation

Installation for Rough-in section for non-IC new construction:

  • 3RN
  • 7RN
  • 3SN
  • 4RN
  • 4SN
  • 6RN
  • 6SN

Caution (RISK OF FIRE)

This is a non-IC rated frame-in kit. Do not install insulation above or within 3 inches (76mm) of any part of luminaire. Use only with LED light modules and reflector trims provided by Signify. Use of other manufacturers trims may void the Underwriters Laboratories listing and could constitute a fire hazard.

May require minimum center-to-center spacing installation. Must reference light module instruction sheet IS-MS_IC.

Instructions for grid ceiling applications

Step 1
Preparation: Cut appropriately sized hole in ceiling tile (by others) at the position desired and place ceiling tile in grid (by others) (Fig.A). Loosen wing nuts on mounting bar clamps enough to allow free movement of mounting bars (Fig.B).

Round
Specifications

Square

Fig. A
Instructions for grid
Fig. B
Instructions for grid

Step 2
Position Frame: Place frame on top of ceiling tile and center the frame aperture on the ceiling tile hole cut in step 1. Orient the frame to align with the grid. Grasp the T-bar clips on each end, one in each hand, lift the clips to the top of the adjustment slots in the end bracket, extend the end brackets to contact the ceiling grid, and drop each T-bar clip over the grid (Fig.C).
Fig. C
Instructions for grid

Step 3
Clamp to Grid and Lock Frame:
Making certain that the frame is still centered on the ceiling tile, tighten the T-bar clip wing nuts to attach the frame to the ceiling grid. Re-tighten the mounting bar clamps after the frame is positioned satisfactorily and is locked to the ceiling grid.

Instructions for wood frame ceiling applications

Step 1
Preparation: Remove wing nuts on T-bar clips and remove clips from frame. Discard both the clips and wing nuts (Fig.D). Loosen wing nuts on frame clamps enough to allow free movement of mounting bars (Fig.B).
Fig. D
Instructions for wood frame

Step 2
Position and install frame: Position frame between joists with the end bracket at one end placed against, and flush to, the bottom of the joist. When positioned, fasten end bracket with nail or screw through any of the provided holes in the bracket (Fig.E). Extend the end bracket at the opposite end of the frame until it contact the opposite joist. Align and attach.
Slide the frame along the mounting bars until the aperture is in the desired position and lock the frame in place by tightening the wing nuts on the mounting bar clamps.
Fig. E
Instructions for wood frame

Note: The mounting bars may be readily adjusted to fit openings between 13″ (330mm) minimum and 24″ (610mm) maximum.

Instructions for metal furring / hat channel applications (1/2, 7/8, &

1-1/2)

Step 1
Preparation: Loosen wing nuts on mounting bar clamps enough to allow free movement of mounting bars (Fig. F).
Fig. F

Step 2
Position and install frame: Each of the three size channels utilize one of the three positioning slots located on each end of the mounting bar system (Fig.F) and on the T-bar clips (Fig.G). Bend the slotted tabs on end of one of the mounting bar system to approximately 45°from original position.
Place this prepared bar end onto one of the channels, then extend the other bar end to the opposite channel, ensuring the slot chosen positions the frame flush with the bottom of the channel. Bend the remaining two slotted tabs into position it to align with the other channel. Drop both T-bar clips over the edge of channel and tighten wing nut to secure.
Slide the frame along the mounting bars until the aperture is in the desired position and lock the frame in place by tightening the wing nuts on the mounting bar clamps.
Fig. G

Mounting system is designed to install into channel with a height dimension of 1/2″, 7/8″ or 1-1/2″.

Instructions for all applications

Wire in: Wire to supply leads. Wire neutral lead supply lead to white wire, hot supply lead to black wire, and bare copper and/or green wire must be connected to supply ground. Use wire nuts (local hardware item). Place all electrical connections in the j-box and close j-box door.

For luminaires with 0-10V dimming, or digital dimming: wire purple & gray leads to appropriate control wires. Additional orange wire is for future expansion and should remain capped off when not in use.

For square frames: adjustment of the position can be accomplished by loosening the wing nut clamp and rotating the inner square of the frame. Re- tighten the wing nut clamps when appropriately positioned.

For Color Kinetics iHue driver applications: wire the data conductor from the Color Kinetics Data Enabler to the purple conductor.
The data conductor from the Color Kinetics Data Enabler provides a proprietary control signal, that is required to operate the luminaire.
CAUTION – The data conductor is NOT isolated.

Data Enabler Pro
https://www.colorkinetics.com/global/products/pds/dataenablerpro

© 2019 Signify Holding. All rights reserved. This document may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. All trademarks are owned by Signify Holding or their respective owners.

Signify Canada Ltd.
281 Hillmount Road.
Markham, ON. Canada L6C 2S3
Telephone 800-668-9008

Signify North America Corporation
200 Franklin Square Drive.
Somerset. NJ 08873
Telephone 855-486-2216

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals