elk HOME 82192/3 Forma de Crystal 23 Inch Wide 3 Light Vanity Light Instruction Manual

June 10, 2024
elk HOME

elk HOME-logo

elk HOME 82192/3 Forma de Crystal 23 Inch Wide 3 Light Vanity Light

elk HOME-82192-3-Forma-de-Crystal-23-Inch-Wide-3-Light-Vanity-Light-
product

Product Information

The product is a light fixture that is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. The package includes a mounting bracket (A), wall screws (G), junction box screws (B), wire nut (C), wall anchor (F), and a ground screw. The product comes with a warning to disconnect power at the main fuse box before installation, and if the user is not familiar with code requirements, an installation by a certified electrician is recommended.

Product Usage Instructions

  1. Disconnect power at the main fuse box before installation.

  2. Remove all parts and part packages from the box. If anything is missing, contact the retailer from which the product was purchased.

  3. Position mounting bracket (A) so the head of ground screw is facing outward. The tabs on mounting bracket (A) should be at the top and bottom and facing outward.

  4. Temporarily place the mounting bracket (A) over the junction box. Align the holes in the center of mounting bracket (A) with holes in junction box. Mark on the wall the location of each hole in each corner of mounting bracket (A) (4 holes total). Place mounting bracket (A) aside.

  5. Using a drill bit the appropriate size of the wall anchor (F), drill a hole at each marked location in the wall. Carefully insert wall anchor (F) into each hole in the wall.

  6. Carefully pull house wires through the hole in the center of mounting bracket (A).

  7. Align holes in each corner of mounting bracket (A) with each wall anchor (F). Align holes in center of mounting bracket (A) with each hole in junction box. Mounting bracket (A) should be level.

  8. Thread each wall screw (G) into holes in corners of mounting bracket (A) and into wall anchors (F). DO NOT fully tighten wall screws (G) at this time.

  9. Thread each junction box screw (B) into holes in center of mounting bracket (A) and into holes in junction box. Tighten junction box screws (B) and wall screws (G) to secure mounting bracket (A) to junction box.
    CAUTION: Make sure house wires are pulled completely through the hole in mounting bracket. DO NOT pinch wires between mounting bracket and wall.

  10. Strip 3/4 of insulation from ends of fixture wires.

  11. Slightly loosen ground screw on mounting bracket (A). Do not completely remove ground screw. Wrap house ground wire (copper) around ground screw, leaving enough ground wire to attach to fixture ground wire. Twist end of fixture ground wire and end of house ground wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart below for correct wire connections. Connect Supply (House) Ground Copper Wire to: Bare Copper Wire or, Bare Silver Wire or, Green Insulated Wire.

  12. Twist end of house lead wire (black) and end of fixture lead wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C).

  13. Twist end of house neutral wire (white) and end of fixture neutral wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart to the right for correct wire connections.

INSTALLATION INSTRUCTION

WARNING: DISCONNECT POWER AT THE MAIN FUSE BOX BEFORE INSTALLATION.

  • This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.
  • Before assembly, remove all parts and part packages from box. If anything is missing, please contact the retailer from which the product was purchased.
  1. Position mounting bracket (A) so the head of ground screw is facing outward. The tabs on mounting bracket (A) should be at the top and bottom and facing outward.

  2. Temporarily place the mounting bracket (A) over the junction box. Align the holes in the center of mounting bracket (A) with holes in junction box. Mark on the wall the location of each hole in each corner of mounting bracket (A) (4 holes total). Place mounting bracket (A) aside.

  3. Using a drill bit the appropriate size of the wall anchor (F), drill a hole at each marked location in the wall. Carefully insert wall anchor (F) into each hole in wall.

  4. Position mounting bracket (A) so the head of ground screw is facing outward. The tabs on mounting bracket (A) should be at the top and bottom and facing outward.

  5. Carefully pull house wires through hole in center of mounting bracket (A).

  6. Align holes in each corner of mounting bracket
    (A) with each wall anchor (F). Align holes in center of mounting bracket (A) with each hole in junction box. Mounting bracket (A) should be level.

  7. Thread each wall screw (G) into holes in corners of mounting bracket (A) and into wall anchors (F). DO NOT fully tighten wall screws (G) at this time.

  8. Thread each junction box screw (B) into holes in center of mounting bracket (A) and into holes in junction box. Tighten junction box screws (B) and wall screws (G) to secure mounting bracket (A) to junction box.
    CAUTION: Make sure house wires are pulled completely through hole in mounting bracket. DO NOT pinch wires between the mounting bracket and wall.

  9. Strip 3/4” of insulation from ends of fixture wires.

  10. Slightly loosen ground screw on mounting bracket (A). Do not completely remove ground screw. Wrap house ground wire (copper) around ground screw, leaving enough ground wire to attach to fixture ground wire. Twist end of fixture ground wire and end of house ground wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart below for correct wire connections.

Connect Supply (House) Ground Copper Wire to:

Bare Copper Wire or,
Bare Silver Wire or,
Green Insulated Wire.

  1. Twist end of house lead wire (black) and end of fixture lead wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Twist end of house neutral wire (white) and end of fixture neutral wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart to the right for correct wire connections.
  2. Wrap electrical tape (not included) around wire nuts (C) and wires. Ensure wires are securely fastened into wire nuts.
  3. Carefully push all wires and wire nuts into junction box.

Connect Black Lead Supply (House) Wire to:| Connect White Neutral Supply (House) Wire to:
---|---
Black Wire or,| White Wire or,
Parallel Cord (Round and Smooth) or,| Parallel Cord (Square and Ridged) or,
No printed words on wire insulation or,| Printed words on wire insulation or,
Insulated Wire (other than green)

with Copper Conductor.

| Insulated Wire (other than green)

with Silver Conductor.

*When parallel wire (SPT 1 & SPT 2) is used: The lead wire is round in shape or smooth.

The neutral wire is square in shape or ridged.

  1. Place backplate (D) over mounting bracket (A). Align holes in top and bottom of backplate (D) with holes in each tab of mounting bracket (A).
  2. Screw one fixture mounting screw (E) into each hole in top and bottom of backplate (D) and into holes in tabs on mounting bracket (A). Tighten fixture mounting screws (E) to secure fixture to wall.
  3. Raise shade (K) up to fixture. Pass hole in top of shade (K) over socket. Align holes along shade (K) with holes in pegs along socket. Thread one threaded stud (L) into each hole along shade (K) and into holes in pegs on socket. Tighten threaded studs (L) to secure shade (K) in place. DO NOT over tighten.
  4. Repeat step 16 for remaining shade (K).
  5. Screw recommended bulbs (E26 Edison bulb type, not included) into sockets. Verify correct bulb wattage marked on socket of fixture.
    WARNING: DO NOT exceed maximum bulb wattage.elk HOME-82192-3-Forma-de-
Crystal-23-Inch-Wide-3-Light-Vanity-Light-fig-4

elkhome.com

Documents / Resources

| elk HOME 82192/3 Forma de Crystal 23 Inch Wide 3 Light Vanity Light [pdf] Instruction Manual
82192-3, 82192 3, Forma de Crystal 23 Inch Wide 3 Light Vanity Light, 82192 3 Forma de Crystal 23 Inch Wide 3 Light Vanity Light, 23 Inch Wide 3 Light Vanity Light, Wide 3 Light Vanity Light, 3 Light Vanity Light, Vanity Light, Light
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

elk HOME User Manuals

Related Manuals