Delivery Content

  • 1 pc LAN Stick
  • 1 pc Data Logger LAN Stick Quick User Guide

Introduction

Data Logger LAN Stick is mainly used in inverters to realize simple and quick access to Internet. Users can easily check device information by logging in the monitoring center. The communication topology is as shown below:Solis
SOL-DLS-LAN Data Logger LAN Stick - communication Description of Symbols
To ensure normal use of the datalogger, before using the datalogger, be sure that:
a. The connected wireless router can normally access to Internet;
b. The communication address of the inverter MUST BE ” 01″, which is default value.
c. A computer is connected to this device for parameter setting.

Electrical Connection

Connect LAN Stick to the corresponding interface on the inverter. Solis-1P5K- 4G is used as an example in this manual. Please perform relevant operations as indicated below:Solis SOL-DLS-LAN Data Logger LAN Stick - LAN
Stick Data Logger LAN Stick Installation

  1. Insert LAN Stick to COM port.
  2. Fasten the LAN Stick.

Solis SOL-DLS-LAN Data Logger LAN Stick - LAN Stick 1 NOTES
LAN Stick automatically obtains IP by default.
If the network cable supports automatically obtains IP, please jump to “ 3” for APP registration.
If network cable do not support obtains IP automatically , please continue to follow “ 2 ” for IP settings.

LAN configuration

Step 1: Enter 169.254.173.207 in the web browser, open the following configuration interface. (If you can’t open it, please skip to3 ) Enter username admin and password admin. Solis SOL-DLS-LAN Data Logger LAN Stick -
setting 1Step 2: Select the “ Quick Set ”.
Enter IP address、Subnet mask、Gateway address、 DNS server address for network cable. Then click the “ Save ” .(Please enter in the “ 1 Network name ”, otherwise it cannot be saved)Solis SOL-DLS-LAN Data Logger LAN Stick -
setting 2Step 3: The following interface pops up to indicate that the setting is successful, please skip to 4. Otherwise please try LAN configuration again .Solis SOL-DLS-LAN Data Logger LAN Stick -
setting 3

Step 1: With a network cable to connect the computer and LAN Stick, right- click the computer icon in the lower right corner of the computer, enter the network and sharing center.Solis SOL-DLS-LAN Data Logger LAN Stick - setting
4Step 2: Select the local connection options.Solis SOL-DLS-LAN Data Logger LAN Stick - setting
5Step 3: Left double-click ” Properties ” into the ” local connection status”.Solis SOL-DLS-LAN Data Logger LAN Stick -
setting 6Step 4: Left double-click: “Internet Protocol version 4 (TCP / Ipv4) .
Solis SOL-DLS-LAN Data Logger LAN Stick - setting 7Step 5: While the computer’s IP is configured as a static IP (as shown below) .Solis SOL-DLS-LAN Data Logger LAN Stick - setting
8Step 6: Enter 10.10.100.254 in the web browser, open the following configuration interface. Select the “ Network ”.Solis
SOL-DLS-LAN Data Logger LAN Stick - setting 9Step 7: Enter IP address、Subnet mask、Default gateway、Preferred DNS server and Optional DNS server for network cable. Then click the “ Save ” and “ Restart ” to restart the LAN Stick. Solis SOL-DLS-LAN Data Logger LAN
Stick - setting 10

Create Solis monitoring account

Step 1: Mobile phone scan the QR code to download the APP, or in the APP Store or Google Play search Solis Home or Solis Pro.

|
---|---
http://www.ginlongmonitoring.com/GinLongHomeDownload/| http://www.ginlongmonitoring.com/GinLongProDownload/

Step 2: Click on the “Register ”.Solis SOL-DLS-LAN Data Logger LAN Stick -
setting 11Step 3: Fill in the form as required and click the“ Register ”.Solis SOL-DLS-LAN Data Logger LAN Stick - setting
12

Create plant

Step 1:In the APP homepage and click “Build Your Plant Within 1 Minute!” in the middle of the screen. Or click the “+ ” in the upper right corner.Solis
SOL-DLS-LAN Data Logger LAN Stick - setting 13Step 2: Enter the SN of the datalogger.
The datalogger SN can be automatically scanned by placing the purchased device bar code in the scan box. If you can’t scan, you can also manually enter the datalogger SN (just enter the digital serial number).Solis SOL-DLS-LAN Data
Logger LAN Stick - setting 14Note: Please scan the SN number on the datalogger, not the SN number on the inverter. Step 3 :Enter the plant information.Then click the ” Next “.Solis SOL-DLS-LAN Data Logger
LAN Stick - setting 16Step 4 : Enter the plant name and contact information of the plant owner . Then click the “ Done”.
Solis SOL-DLS-LAN Data Logger LAN Stick - setting 17

Distrubutor/Installer create plant

In order to easy registration and easy manage, you can also let the distributor/installer register the plant, then Link it to you .
Click the [ ] and tell the “ ” to your ID Distrubutor/installer to build the plant for you.
(Note: your Distrubutor/installer must have a Solis Pro account)Solis SOL-
DLS-LAN Data Logger LAN Stick - setting 18

Link distributor/installer

Step 1: In order to easy manage to your plant.
Select the plant and enter Intro . Click the ” installer ” or ” distributor ” .Solis SOL-DLS-LAN Data Logger LAN Stick - setting 19Step 2: Enter the company name of the installer or distributor. Then click the “ Search ”.Solis SOL-DLS-LAN Data Logger LAN Stick - setting
20Step 3: Click the [Bind Distributor/Installer ] and the plant will appear in your installer/distributor monitoring interface.
(Note: your installer/distributor must have a Solis Pro account to appear in the search list)Solis SOL-DLS-LAN Data Logger LAN Stick - setting
21 Contact
If you have any technical questions about our products, please contact us.Before contacting us, please confirm the following items:
Equipment model
Serial number of the datalogger
Problem description
Screenshot of the Status page in the configuration interface

Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park,
Xiangshan, Ningbo, Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
Email:info@ginlong.com
Web:www.ginlong.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals