Default Login Information: admin | admin

When logging into the camera for the first time, you will be prompted to set up a new password. You can set the new password using the DW® IP Finder™ software or directly from the camera’s browser menu.

WHAT’S IN THE BOX

Quick Setup and Installation Guide

1 set
Mounting Templates

1
Waterproof Cap and Rubber Rings (Black: ø0.15” (ø4mm), White: ø0.19” (ø5mm))

1 set
Moisture absorber and installation guide (recommended)

1 set
Bolt and Nuts 2pcs

1 set
Screws and Plastic Anchors – 2pcs

1 set
Star Wrench (T-20)

1

NOTE: Download all your support materials and tools in one place

  1. Go to: http://www.digital-watchdog.com/resources

  2. Search your product by entering the part number in the ‘Search by Product’ search bar. Results for applicable part numbers will populate automatically based on the part number you enter.
    QR Code

  3. Click ‘Search’. All supported materials, including manuals and quick start guide (QSGs) will appear in the results.

Attention: This document is intended to serve as a quick reference for the initial set-up. It is recommended that the user read the entire instruction manual for complete and proper installation and usage.

PREPARING TO MOUNT THE CAMERA

  1. The mounting surface must withstand five times the camera weight.

  2. Do not let the cables get caught in improper places or the electric line cover can be damaged. This may cause a short or fire.

  3. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

  4. CAUTION: There is a risk of explosion if the battery is replaced incorrectly and it should be replaced only with the same battery.
    ATTENTION: Il y a risque d’explosion si la batterie est remplacée par une batterie de type incorrect. Mettre au rebut les batteries usages conformément aux instructions.

  5. Used batteries must be disposed of according to local regulations or the battery manufacturer’s instructions. Disposing of batteries in a fire or in a hot oven, or mechanically crushing and cutting them may cause an explosion.

  6. Leaving the battery in very high temperature or low air pressure environments may result in an explosion or leak of flammable liquids or gases.

  7. This product is intended to be supplied by a UL Listed Power Supply Unit marked “Class 2” or “LPS” or “PS2” and rated 12 Vdc, 0.49A (DWC-MPF5Wi and DWC-MF5Wi series) and 0.33A (DWC-MF2Wi and DWC-MPF2Wi series) min.

  8. The wired LAN hub providing power over the Ethernet (PoE) in accordance with IEEE 802-3af shall be a UL Listed device with the output evaluated as a Limited Power Source as defined in UL60950-1 or PS2 as defined in UL62368-1.

  9. Unit is intended for installation in a Network Environment 0 as defined in IEC TR 62102. As such, associated Ethernet wiring shall be limited to inside the building.

  10. For the installation process, remove the dome cover from the camera module by loosening the three (3) screws on the dome. Use the wrench provided with the camera.

  11. Install the moisture packet in the base of the camera’s lens.
    • Remove the moisture absorber from the packaging.
    • Cut the card and folder along the dotted line.
    • Place the moisture absorber around the camera’s lens module.
    Preparing To Mount the Camra

  12. Remove the protective film between the dome and the camera module.
    NOTE: The camera will generate enough heat to dry moisture during operation. In most cases it will not need the moisture absorber for more than the first day. In cases where the camera can experience a moisture issue, users must keep the moisture absorber in the camera.
    The moisture absorber has an approximately 6-month life cycle, varying depending on the environment.
    WARNING: It is highly recommended that you install the moisture absorber when mounting the camera. The moisture absorber prevents moisture from being captured inside the camera’s housing, which may cause image performance issues and damage the camera.

  13. Remove the Poron Ring before placing the dome back on the camera.
    When attaching the dome back, align the line on the dome with the one on base of the camera.

  14. Using the mounting template sheet or the camera itself, mark and drill the necessary holes in the wall or ceiling.

POWERING THE CAMERA

Pass the wires through and make all the necessary connections.

  1. If you are using a PoE switch, connect the camera using an Ethernet cable for both data and power.
  2. If you are using a non-PoE switch, connect the camera to the switch using an Ethernet cable for data transmission and use a power adapter to power the camera.
Models Power requirements Power consumption

DWC-MPF5Wi4TW DWC-MPF5Wi6TW DWC-MPF5Wi8TW DWC-MF5Wi4TW DWC-MF5Wi6TW DWC- MF5Wi8TW| DC 12V, PoE IEEE 802.3af Class 3.(Adapter not included)| DC12V: max 5.9WPoE: max 7.2W
DWC-MPF2Wi4TW DWC-MPF2Wi28TW DWC-MF2Wi4TW DWC-MF2Wi4T DWC-MF2Wi28TW| DC 12V, PoE IEEE 802.3af Class 2.(Adapter not included)| DC12V: max 4WPoE: max 5.5W

INSTALLING THE CAMERA

  1. Attach the main body to the mounting bracket or mounting surface by tightening the lock screw.

  2. For soft installation surfaces, use the included metal mount plate. Fix the mount plate on the mounting surface using the included screws. Then, press the bottom case onto the mount plate. The three bezels on the case will align and snap lock onto the plate.

  3. The waterproof cap set comes with two rubber rings with different diameters. The black rubber ring has an internal diameter of ø0.15” (ø4mm). The white rubber ring has an internal diameter of ø0.19” (ø5mm). When using the waterproof cap, use the rubber ring best suited for your network cable’s diameter.
    a. Pass the LAN cable through the waterproof cap, gasket and the a rubber ring.
    b. Connect the LAN cable to the camera’s network port b .
    c. c will be affixed to b with a ¼ turn counter-clockwise.
    d. Thread and twist d tightly to c .
    Installting The Camra
    NOTE: To ensure moisture seal, make sure the o-ring is in place between a and b . In extreme environments use of an outdoor rated sealer is recommended.
    NOTE: Cables with ø4.5mm to ø5.5mm thickness should use the black rubber ring. Cables over ø5.5mm in thickness should use the white rubber ring.

  4. Once the installation is complete, adjust the camera’s tilt, panning and rotation as needed. The cameras’ max angles are: Pan: 0° ~ 360°, Tilt: 0° ~ 70°, Rotation: 0° ~ 360°

  5. Assemble the dome cover over the camera body and detach the protecting film from the dome bubble.

Installting The Camra

Resetting the camera: To reset the camera, use the tip of a paper clip or a pencil and press the reset button. Pressing the button for five (5) seconds will initiate a camera-wide reset of all the settings, including network settings.
Resetting the camera

Installation using Mount Bolt and Screws:

  1. Using the mounting template, mark and drill the holes on the mounting surface.
  2. Secure the two long mounting screws to the camera’s base.
  3. Pass the wires through the mount bracket and make all necessary connections.
  4. Mount the camera to the mounting surface by using the 2 mounting nuts. Rotate the locking discs over the screws until the camera is held tightly from the mounting surface.
    Installting The Camra

CABLING (DWC-MPF5Wi and DWC-MF5Wi series)

Cabling

DI (+): WHITE
DI ( – ): YELLOW
DO ( – ): SKY BLUE
DO (+): GRAY + DOT

MANAGING THE SD CARD

  1. To install the camera’s SD Card, locate the SD card slot in the back of the camera module.
    Insert a class 10 SD card into the SD card slot by pressing the SD card slot.

  2. To remove the SD Card, press the card inward to release from the card slot.
    Managing the SD Card

DW IP FINDER

Use the DW® IP Finder™ software to scan the network and detect all MEGApix® cameras, set the camera’s network settings or access the camera’s web client.

Dw Ip Finder

Network Setup

  1. To install the DW IP Finder, go to: http://www.digital-watchdog.com

  2. Enter “DW IP Finder” on the search box at the top of the page.

  3. Go to the “Software” tab on the DW IP Finder page to download the installation file.

  4. Follow the installation to install the DW IP Finder. Open the DW IP Finder and click ‘Scan Devices’. It will scan the selected network for all supported devices and list the results in the table. During the scan, the DW® logo will turn gray.

  5. When connecting to the camera for the first time, a password must be set. To set up a password for your camera:
    a. Check the box next to the camera in the IP Finder’s search results. You can select multiple cameras.
    b. Click “Bulk Password Assign” on the left.
    c. Enter admin/admin for the current username and password. Enter a new username and password to the right.
    Passwords must have a minimum of 8 characters with at least 4 combinations of uppercase letters, lowercase letters, numbers and special characters. Passwords cannot contain the user ID.
    d. Click “change” to apply all changes.

  6. Select a camera from the list by double-clicking on the camera’s image or clicking on the ‘Click’ button under the IP Conf. column. The pop-up window will show the camera’s current network settings, allowing admin users to adjust the settings as needed.

  7. To access the camera’s web page, click on the ‘View Camera Website’ from the IP Config window.

  8. To save changes made to the camera’s setting, enter the username and password of the camera’s admin account and click ‘Apply’.
    Select DHCP to allow the camera to receive its IP address automatically from the DHCP server. Select “Static” to manually enter the camera’s
    IP address, (Sub)Netmask, Gateway and DNS information.
    The camera’s IP must be set to static if connecting to Spectrum® IPVMS. Contact your network administrator for more information.
    Default TCP/IP information: DHCP
    Port forwarding must be set in your network’s router to access the camera from an external network.
    Camera Setting

WEB VIEWER

Web Viewer

NOTE: Chrome browser is recommended for IVA configuration.

Once the camera’s network settings have been setup properly, you can access the camera’s web viewer using the DW IP Finder.

To open the camera’s web viewer:

  1. Find the camera using the DW IP Finder.

  2. Double-click on the camera’s view in the results table.

  3. Press the ‘View Camera Website’. The camera’s web viewer will open up in your default web browser.

  4. Enter the camera’s username and password you setup in the DW IP Finder. If you did not setup a new username and password via the DW IP Finder, you will not be able to view video from the camera. A message will direct you to setup a new password for the camera to view video.
    Change Password

  5. When accessing the camera for the first time, install the VLC player for web files to view video from the camera.
    NOTE: 32bit version of the VLC player must be installed. If you are using a 64bit system, uninstall the previous 64bit version and reinstall using the 32bit version.
    NOTE: Some menu options may not be available based on the camera model. See the full manual for more information.

Tel: +1 866-446-3595 / 813-888-9555
Technical Support Hours:
9:00 AM – 8:00 PM EST, Monday through Friday

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DIGITAL WATCHDOG User Manuals

Related Manuals