AES e-LOOP Fitting Commercial Radar Kit Instructions
- June 10, 2024
- AES
Table of Contents
- AES e-LOOP Fitting Commercial Radar Kit **
- Product Information:
- Product Usage
- e-LOOP Fitting Instructions
- Coding e-LOOP with Magnet (Commercial systems only)
- Uncalibrated e-LOOP
- Changing mode
- Contact Information
- Specifications
- Parameters that can be altered
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AES e-LOOP Fitting Commercial Radar Kit **
**
Product Information:
- Frequency: 433.39 MHz
- Security: 128-bit AES encryption
- Range: up to 50 meters
- Battery life: up to 10 years
- Battery type: Lithium-ion 3.6V 2600 mA x 4
Product Usage
e-LOOP Fitting Instructions
- Power up the e-Trans 50 and hold the e-Loop within 10cm of the transceiver’s antenna.
- Press and release the CODE button on the e-Trans 50. The yellow and red LEDs will flash on the e-Loop, and the blue LED on the e-Trans 50 will flash 3 times. The systems are now paired. (For coding the e-Trans 200 LCD transceiver refer to the e-Trans 200 manual.) (For coding the e-Trans 200 LCD transceiver refer to the e-Trans 200 manual.)
Coding e-LOOP with Magnet (Commercial systems only)
- Power up the e-Trans 50, then press and release the CODE button. The blue LED on the e-Trans 50 will light up.
- Place the e-LOOP device in the desired location and secure it into the ground using 2 concrete fixing bolts. Ensure the e-LOOP device is secured and can’t be moved when touched. (Never fit near high voltage cables, this can affect the e-LOOP’s detection capability.)
- Move any metal objects away from the e-LOOP.
- Place the magnet into the SET button recess on the e-LOOP until the red LED flashes twice, then remove the magnet.
- The e-LOOP will take about 5 seconds to calibrate and once complete, the red LED will flash 3 times.
Uncalibrated e-LOOP
- Place the magnet into the SET button recess until the red LED flashes 4 times, e-LOOP is now uncalibrated.
Changing mode
The e-LOOP is set to pulse mode as a standard setting. This can be changed to presence mode via the menu in the e-TRANS-200 LCD transceiver – refer to the manual.
(Note: this menu cannot be accessed via the eTRANS-50 Transceiver.)
- Pulse / Presence mode. (Note: do not use presence mode as a safety function.)
- Wake-up time intervals for presence mode.
- Sensitivity detection level for Pulse mode.
- Sensitivity detection for presence mode by each axis : Above / Approach / Side.
- Radar detection distance.
Note: After calibration, you may get an error indication.
- ERROR 1: Low radio range – Yellow LED flashes 3 times.
- ERROR 2: No radio connection – Yellow and Red LED flashes 3 times.
Disclaimer: Units with the presence feature are not to be used as a sole safety device and should be used in conjunction with standard gate safety practices.
Contact Information
- Email: sales@aesglobalonline.com
- Phone: +44 (0) 288 639 0 693
- Website: www.aesglobalonline.com
Specifications
- Frequency: 433.39 MHz.
- Security: 128-bit AES encryption.
- Range: up to 50 meters.
- Battery life: up to 10 years.
- Battery type: Lithium-ion 3.6V 2600 mA x 4.
Step 2 – Fitting e-LOOP
- 1. Place the e-LOOP device in the desired location and secure it into the ground using 2 concrete fixing bolts. Ensure the e-LOOP device is secured and can’t be moved when touched.
NOTE: Never fit near high-voltage cables, this can affect the e-LOOP’s detection capability.
Step 3 – Calibrate e-LOOP
- Move any metal objects away from the e-LOOP.
- Place the magnet into the SET button recess on the e-LOOP until the red LED flashes twice, then remove the magnet.
- The e-LOOP will take about 5 seconds to calibrate and once complete, the red LED will flash 3 times.
NOTE: After calibration, you may get an error indication.
ERROR 1: Low radio range – Yellow LED flashes 3 times.
ERROR 2: No radio connection – Yellow and Red LED flashes 3 times.
The system is now ready.
- Place the magnet into the SET button recess until the red LED flashes 4 times, e-LOOP is now uncalibrated.
Parameters that can be altered
- Pulse / Presence mode. NOTE: do not use presence mode as a safety function.
- Wake-up time intervals for presence mode.
- Sensitivity detection level for Pulse mode.
- Sensitivity detection for presence mode by each axis: Above / Approach / Side.
- Radar detection distance.
DISCLAIMER: UNITS WITH THE PRESENCE FEATURE IS NOT TO BE USED AS A SOLE SAFETY DEVICE & SHOULD BE USED IN CONJUNCTION WITH STANDARD GATE SAFETY PRACTICES.
E. sales@aesglobalonline.com
T: +44 (0) 288 639 0 693
www.aesglobalonline.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>