- Introduction
- Hardware Description
- Mechanical View
- Installation
- Wall Installation
- Pole Mounting Installation
- Connecting Network Cables
- Connecting Fiber Optic Cable
- Connecting Power Cable
- Appendix A: Safety and Warnings
- Appendix B: Troubleshooting
- Appendix C: Specifications
- Appendix D: Standards
- Appendix E: Recycling and Disposal
- Ordering Information
- References
- Revision History
- Microchip Information
- Product Change Notification Service
- Customer Support
- Microchip Devices Code Protection Feature
- Legal Notice
- Trademarks
- Quality Management System
- Worldwide Sales and Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PDS-204GCO/AC Outdoor 4 Port BT PoE Switch 2 SFP Uplink Port Hardware
Product Information
PDS-204GCO/ACTM Outdoor 4 Port BT PoE Switch + 2 SFP Uplink Port The PDS- 204GCO/ACTM is an outdoor switch with four Power over Ethernet (PoE) ports and two Small Form-factor Pluggable (SFP) uplink ports. The switch is designed for outdoor use and is equipped with IP67-rated weather protection to withstand harsh weather conditions. The PoE ports provide power to PoE-enabled devices, such as wireless access points, IP cameras, and VoIP phones, eliminating the need for separate power cables. The SFP uplink ports provide high-speed connectivity to other network devices.
Hardware Description
The switch has the following hardware features:
- Four PoE ports
- Two SFP uplink ports
- IP67-rated weather protection
- Power input voltage range: 48V DC to 56V DC
- Power consumption: maximum 60W
Mechanical View
The switch has a compact and sturdy metal enclosure with mounting brackets for wall and pole installations. The dimensions of the switch are 205mm x 130mm x 44mm (WxDxH).
Installation
Before installation, ensure that you have read and understood the safety instructions provided in the user manual.
Wall Installation
- Choose a suitable location for the switch that is protected from direct sunlight and rain.
- Attach the mounting brackets to the switch using the screws provided.
- Use the screws and wall anchors provided to attach the switch to the wall.
Pole Mounting Installation
- Choose a suitable location for the switch on the pole that is protected from direct sunlight and rain.
- Attach the mounting brackets to the switch using the screws provided.
- Use the stainless steel straps provided to attach the switch to the pole.
Connecting Gigabit Ethernet Cable
- Connect one end of the Ethernet cable to one of the PoE ports on the switch.
- Connect the other end of the Ethernet cable to the PoE-enabled device.
Connecting Fiber Optic Cable
- Insert one end of the SFP module into one of the SFP uplink ports on the switch.
- Insert the other end of the SFP module into the SFP slot of the fiber optic transceiver.
- Connect one end of the fiber optic cable to the fiber optic transceiver.
- Connect the other end of the fiber optic cable to another network device, such as a switch or router.
Connecting Power Cable
- Connect one end of the power cable to the power input port on the switch.
- Connect the other end of the power cable to a power source that supplies 48V DC to 56V DC.
Troubleshooting
The user manual provides an Appendix B with troubleshooting tips for common issues that may occur during installation or operation of the switch.
Specifications
The user manual provides an Appendix C with the specifications for the switch, including details on the hardware, power consumption, and environmental conditions.
Standards
The user manual provides an Appendix D with information on the standards and regulations that the switch complies with, including FCC and CE regulations.
Recycling and Disposal
The user manual provides an Appendix E with information on how to recycle and dispose of the switch in an environmentally responsible manner.
Ordering Information
The user manual provides an ordering information section with details on how to order replacement parts or additional switches.
References
The user manual provides a references section with a list of documents and resources for further information on the switch.
Revision History
The user manual provides a revision history section with details on the changes made to the manual over time.
Introduction
Microchip’s PDS-204GCO™ switch is a 4 + 2 ports outdoor PoE switch. It can provide power and data connectivity for four powered devices and connect them to the network through data uplink ports. The PDS-204GCO switch can be remotely managed through the web or SNMP, allowing monitoring and control of the device and its ports. The PDS-204GCO switch supports 10/100/1000 Mbps data rates on the RJ45 Gigabit ports and 100/1000/2500 Mbps on the SFP ports. It is powered through wide-range AC input (100 VAC–240 VAC). The PDS-204GCO switch is IP66/IP67 rated and has an extended temperature range. Therefore, it can be installed in an outdoor environment. In a typical installation, the PDS-204GCO switch provides power to four outdoor devices, such as WLAN AP, WLAN Mesh, IP Camera, and so on.
Audience
This guide is designed for personnel who install and maintain the switch. These persons must be familiar with electronic circuitry and wiring practices, and qualified and experienced electronic or electromechanical technicians.
Hardware Description
This switch provides two SFP ports for uplink and four GE copper PoE ports for downstream connectivity. The PDS-204GCO switch can be either wall or pole mounted.
The PDS-204GCO switch provides the following hardware features:
- Two SFP ports 100/1000/2500Base-X
- Four copper PoE 10/100/1000BASE-T ports
- Up to 90W PoE copper per port
- Maximum total power 152W
- Management Ethernet port (any of the ports can be used as Management)
- Fan-less passively cooled design
- AC input
- IP66/IP67 enclosure
- Four Copper cable glands
- Two fiber cable glands + cable gland extender
- Six ports cable gland caps
- Mechanical mounting kit—enables pole mounting (including with unit)
Mechanical View
The following figures show the mechanical view of the PDS-204GCO switch. Figure 2-1. Mechanical View
Installation
This section describes the installation process of the PDS-204GCO switch.
CAUTION: Ensure the following before mounting the PDS-204GCO switch to a fixed location:
- Weather-proof connection is present. To meet IEC60529 level IP66/IP67, the PDS-204GCO AC power plug must be connected to a weather-proof AC power source box.
- There is no ON or OFF switch; plug the PDS-204GCO switch into an AC main power source.
- PDS-204GCO AC power lines must be connected to the socket-outlet. This socket-outlet must be installed near the equipment and must be easily accessible.
WARNING
PDS-204GCO unit must be connected to earth grounding using a customer-supplied ground wire before power is applied.
Wall Installation
The PDS-204GCO unit can be mounted on a wall/bench (all kinds of flat
surfaces: wood, brick, concrete, and so on) using the mounting holes.
Fasten the PDS-204GCO using four screws, as shown in the following figure.
Figure 3-1. Wall Mounting
Pole Mounting Installation
The following table lists the kit details supplied with the product.
Table 3-1. PDS-204GCO Kit Details
Item Description | Quantity |
---|---|
Pole bracket | 2 |
Worm screw clamps | 2 |
SCREW M5X18 | 4 |
Perform the following steps for pole mounting installation.
- Attach the pole bracket to the switch using four pan head screws and tighten the pan head screws to 1.1 Nm.
- The unit must be installed with DATA IN, and DATA & PWR OUT ports facing down, as shown in the following figures. Dimensions of support Pole diameter: 60 mm to 200 mm (2.5 inches to 8 inches)
Table 3-2. Installation of Units on Pole
Connecting Network Cables
This section describes how to connect the following PDS-204GCO interfaces.
Connecting Gigabit Ethernet Cable
Perform the following steps to connect the Gigabit Ethernet cable.
- Remove the metal gland from the PDS-204GCO unit by turning it counterclockwise. Keep the dust cap for future use.
- Insert the cable through metal gland, rubber seal, and pressure fingers and plug into the port number 1.
- Secure all glands till the rubber gasket is tightly closed around the cable.
- Ethernet cable
- Metal gland
- Rubber seal
- Pressure fingers
Notes:
- For easier installation, start with port number 1 assembly (Data & PWR 1), and then connect the Uplink port.
- Use cable Cat 5e or above outdoor grade.
- Secure the gland until the rubber gasket is firmly closed around the cable.
- The PDS-204GCO switch is not shipped with Ethernet cable and RJ45 male connectors.
Connecting Fiber Optic Cable
Figure 4-1. Connecting Fiber Optic Cable
- Remove the metal gland from the PDS-204GCO unit by turning it counterclockwise. Keep the dust cap for future use.
- Insert the cable through metal gland, rubber seal, and pressure fingers and plug into the Uplink port.
- Secure the gland until the rubber gasket is firmly closed around the cable.
Note: SFP cord must be outdoor use grade.
Connecting Power Cable
The following table lists the AC power cable specifications.
Table 5-1. AC Power Cable Specifications
Parameter | Value |
---|---|
Recommended cable type | North America—SJOW or SOOW |
Worldwide—H05RN-F or H07RN-F
Voltage rating| 300V (or better recommended)
Temperature range| −40 ℃ to 65 ℃ (or better recommended)
Cable size| 16 AWG–18 AWG 3C
1.0 mm2–1.5 mm2 3C
Cable outer dimension| Diameter: 3/16 in.–3/8 in.
Diameter: 5.0 mm–9.5 mm
Approved for indoor and outdoor applications.
The following figures show how to connect the power connector. Figure 5-1. Connecting AC Connect or
Figure 5-2. AC Connector Assembly
Appendix A: Safety and Warnings
The following sections describe safety information and warnings.
Safety Information
- Installation and removal of the PDS-204GCO unit must be carried out by qualified personnel only.
- The PDS-204GCO DATA PWR OUT ports are shielded RJ45 data sockets. They cannot be used as Plain Old Telephone Service (POTS) sockets. Only RJ45 data connectors can be connected to these sockets.
- Follow basic electricity safety measures while connecting the PDS-204GCO unit to its power source.
- A voltage mismatch can cause equipment damage and might pose a fire hazard. If the voltage indicated on the label is different from the power outlet voltage, do not connect the PDS-204GCO to this power outlet.
- All wiring and connections must be in accordance with NFPA 70 (NEC).
- This product is not intended to become a permanent part of the building structure.
- Power supply cord must not be attached to the building surface or run through walls, ceilings, floors, and similar openings in the building structure.
- Measures must be taken to prevent physical damage to the power supply cord, including proper routing.
Warnings
- Do not use a cross-over cable between the PDS-204GCO output port and the load device.
- Take extra care when connecting the AC power, so that “N”, “L”, and “Ground”, are connected to the proper polarity.
- Ensure that the AC power is within the allowed range.
Appendix B: Troubleshooting
Table 7-1. Troubleshooting Symptoms and Solutions
Symptom | Corrective Steps |
---|---|
Unit does not power up | 1. Verify that a reliable power cord is used. |
2. Verify that the voltage at the power inlet is between 100 VAC–240 VAC.
3. Remove and re-apply power to the device.
PD does not operate| 1. Verify that the unit detects a PD.
2. Verify that the PD is designed for PoE operation.
3. Verify that a standard Category 5/5e/6 cable is in use – Straight wired cable, with four pairs.
4. If an external power splitter is in use, replace it with a splitter known to be in good condition.
5. Ensure that the input Ethernet cable is connected to the Up-link port.
6. Verify that the PD is connected to the Data & Power port.
7. Try reconnecting the same PD to a different PoE switch. If it works, then there is probably a faulty port or faulty RJ45 connection.
8. Verify that there is no short-circuit over any of the twisted pair cables or over the RJ45 connectors.
The end device operates, but there is no data link| 1. Verify that the port indicator on the unit GUI (Wed page) is continuously lit.
2. If an external power splitter is in use, then replace it with a splitter known to be in good condition.
3. Verify that for this link, you are using standard UTP/FTP Category 5 straight (non-crossover) cabling, with all four pairs.
4. Verify that the Ethernet cable length is less than 100 meters from Ethernet source to the remote terminal.
5. Try to reconnect the same PD to a different PoE switch. If it works, then there is probably a faulty port or faulty RJ45 connection.
Appendix C: Specifications
The following table lists the environmental specifications. Table 8-1. Environmental Specifications
Mode | Temperature | Humidity |
---|---|---|
Operating | −40 ℃ to 50 ℃ for 152W (−40 ℉ to 122 ℉) |
−40 ℃ to 60 ℃ for 90W
(−40 ℉ to 140 ℉)
| 10% to 90% (no condensation allowed)
Storage| −40 to 85 ℃
(−40 ℉ to 185 ℉)
| 5% to 95%
The following table lists the electrical specifications. Table 8-2. Electrical Specifications
Parameters | Value |
---|---|
Input Voltage | 100 VAC–240 VAC (50 Hz–60 Hz) |
Input Current
(100 VAC–240 VAC)
| 2.5A (max.)
Available Output Power (max.)| 152W
Nominal Output Voltage| 55 VDC
The following table lists the specifications of the interface. Table 8-3. Interface
Parameters | Value |
---|
Uplink
PDS-204GCO:
• 1000BASE-X
• 2500BASE-X
• 100BASE-FX
| SFP cage
Output (DATA PWR OUT)| RJ45 female socket, with DC voltage
AC Power IN| 3 Pins AC power in—Line, Neutral, and Earth Ground.
Appendix D: Standards
PDS-204 EMC Compliance
- CE:
- EN55035, EN61000-4-5 Class 5 (6KV on AC in)
- EN55032 class B
- FCC Part 15 class B
- VCCI
PDS-204 Safety Compliance
- UL/EN/IEC 62368-1
- UL60950-22
- D-Mark
PDS-204 Lightning Protection
Designed to meet GR-1089-CORE (issue 4) lightning protection requirements.
Other Standards and Approvals
- IEEE® 802.3bt (PoE) standards
- RoHS compliant
- WEEE compliant
- REACH compliant
- Dust and water intrusion
- IEC60529, level IP66/IP67
- NEMA 250, level 4x
Appendix E: Recycling and Disposal
This section provides disposal instructions for old products. The WEEE (Waste Electrical and Electronic Equipment) national environmental initiatives have been put in place to ensure that products are recycled using best available treatment, recovery, and recycling techniques to ensure human health and high environmental protection. Your product is designed and manufactured with high quality materials and components, which can be recycled and reused. Do not dispose of your old product in your general Household waste bin. Inform yourself about the local separate collection system for electrical and electronic products marked by the following symbol.
Use one of the following disposal options:
- Dispose the complete product (including its cables, plugs, and accessories) in the designated WEEE collection facilities.
- If you purchase a replacement product, hand your complete old product back to the retailer. He must accept it, as required by the national WEEE legislation.
Ordering Information
Item | Description |
---|---|
Product Name | Microchip Outdoor PoE Switch |
Part Number | PDS-204GCO/AC |
Description | 4 PoE ports + 2 SFP uplink port |
References
For additional information, see the following related documents:
- Microchip Getting Started With PDS204GCO™ Switch Configuration User Guide
- Microchip PDS-204GCO™ Web Management User Guide
- Microchip PDS-204GCO™ Command Line Interface (CLI) User Guide
Revision History
The revision history describes the changes that were implemented in the document. The changes are listed by revision, starting with the most current publication.
Revision | Date | Description |
---|---|---|
A | 12/2022 | Initial Revision |
Microchip Information
Microchip provides online support via our website at www.microchip.com/. This website is used to make files and information easily available to customers. Some of the content available includes:
- Product Support: Data sheets and errata, application notes and sample programs, design resources, user’s guides and hardware support documents, latest software releases and archived software
- General Technical Support: Frequently Asked Questions (FAQs), technical support requests, online discussion groups, Microchip design partner program member listing
- Business of Microchip: Product selector and ordering guides, latest Microchip press releases, listing of seminars and events, listings of Microchip sales offices, distributors and factory representatives
Product Change Notification Service
Microchip’s product change notification service helps keep customers current
on Microchip products. Subscribers will receive email notification whenever
there are changes, updates, revisions or errata related to a specified product
family or development tool of interest.
To register, go to www.microchip.com/pcn and
follow the registration instructions.
Customer Support
Users of Microchip products can receive assistance through several channels:
- Distributor or Representative
- Local Sales Office
- Embedded Solutions Engineer (ESE)
- Technical Support
Customers should contact their distributor, representative or ESE for support. Local sales offices are also available to help customers. A listing of sales offices and locations is included in this document. Technical support is available through the website at: www.microchip.com/support
Microchip Devices Code Protection Feature
Note the following details of the code protection feature on Microchip products:
- Microchip products meet the specifications contained in their particular Microchip Data Sheet.
- Microchip believes that its family of products is secure when used in the intended manner, within operating specifications, and under normal conditions.
- Microchip values and aggressively protects its intellectual property rights. Attempts to breach the code protection features of Microchip product is strictly prohibited and may violate the Digital Millennium Copyright Act.
- Neither Microchip nor any other semiconductor manufacturer can guarantee the security of its code. Code protection does not mean that we are guaranteeing the product is “unbreakable”. Code protection is constantly evolving. Microchip is committed to continuously improving the code protection features of our products.
Legal Notice
This publication and the information herein may be used only with Microchip
products, including to design, test, and integrate Microchip products with
your application. Use of this information in any other manner violates these
terms. Information regarding device applications is provided only for your
convenience and may be superseded by updates. It is your responsibility to
ensure that your application meets with your specifications. Contact your
local Microchip sales office for additional support or, obtain additional
support at www.microchip.com/en-us/support/design-help/client-support-
services.
THIS INFORMATION IS PROVIDED BY MICROCHIP “AS IS”. MICROCHIP MAKES NO
REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN
OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION INCLUDING BUT NOT
LIMITED TO ANY IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY, AND
FITNESS FOR A PARTICULAR PURPOSE, OR WARRANTIES RELATED TO ITS CONDITION,
QUALITY, OR PERFORMANCE. IN NO EVENT WILL MICROCHIP BE LIABLE FOR ANY
INDIRECT, SPECIAL, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL LOSS, DAMAGE, COST,
OR EXPENSE OF ANY KIND WHATSOEVER RELATED TO THE INFORMATION OR ITS USE,
HOWEVER CAUSED, EVEN IF MICROCHIP HAS BEEN ADVISED OF THE POSSIBILITY OR THE
DAMAGES ARE FORESEEABLE. TO THE FULLEST EXTENT ALLOWED BY LAW, MICROCHIP’S
TOTAL LIABILITY ON ALL CLAIMS IN ANY WAY RELATED TO THE INFORMATION OR ITS USE
WILL NOT EXCEED THE AMOUNT OF FEES, IF ANY, THAT YOU HAVE PAID DIRECTLY TO
MICROCHIP FOR THE INFORMATION.
Use of Microchip devices in life support and/or safety applications is
entirely at the buyer’s risk, and the buyer agrees to defend, indemnify and
hold harmless Microchip from any and all damages, claims, suits, or expenses
resulting from such use. No licenses are conveyed, implicitly or otherwise,
under any Microchip intellectual property rights unless otherwise stated.
Trademarks
The Microchip name and logo, the Microchip logo, Adaptec, AVR, AVR logo, AVR Freaks, BesTime, BitCloud, CryptoMemory, CryptoRF, dsPIC, flexPWR, HELDO, IGLOO, JukeBlox, KeeLoq, Kleer, LANCheck, LinkMD, maXStylus, maXTouch, MediaLB, megaAVR, Microsemi, Microsemi logo, MOST, MOST logo, MPLAB, OptoLyzer, PIC, picoPower, PICSTART, PIC32 logo, PolarFire, Prochip Designer, QTouch, SAM-BA, SenGenuity, SpyNIC, SST, SST Logo, SuperFlash, Symmetricom, SyncServer, Tachyon, TimeSource, tinyAVR, UNI/O, Vectron, and XMEGA are registered trademarks of Microchip Technology Incorporated in the U.S.A. and other countries. AgileSwitch, APT, ClockWorks, The Embedded Control Solutions Company, EtherSynch, Flashtec, Hyper Speed Control, HyperLight Load, Libero, motorBench, mTouch, Powermite 3, Precision Edge, ProASIC, ProASIC Plus, ProASIC Plus logo, Quiet- Wire, SmartFusion, SyncWorld, Temux, TimeCesium, TimeHub, TimePictra, TimeProvider, TrueTime, and ZL are registered trademarks of Microchip Technology Incorporated in the U.S.A. Adjacent Key Suppression, AKS, Analog-for-the-Digital Age, Any Capacitor, AnyIn, AnyOut, Augmented Switching, BlueSky, BodyCom, Clockstudio, CodeGuard, CryptoAuthentication, CryptoAutomotive, CryptoCompanion, CryptoController, dsPICDEM, dsPICDEM.net, Dynamic Average Matching, DAM, ECAN, Espresso T1S, EtherGREEN, GridTime, IdealBridge, In-Circuit Serial Programming, ICSP, INICnet, Intelligent Paralleling, IntelliMOS, Inter-Chip Connectivity, JitterBlocker, Knob-on- Display, KoD, maxCrypto, maxView, memBrain, Mindi, MiWi, MPASM, MPF, MPLAB Certified logo, MPLIB, MPLINK, MultiTRAK, NetDetach, Omniscient Code Generation, PICDEM, PICDEM.net, PICkit, PICtail, PowerSmart, PureSilicon, QMatrix, REAL ICE, Ripple Blocker, RTAX, RTG4, SAM-ICE, Serial Quad I/O, simpleMAP, SimpliPHY, SmartBuffer, SmartHLS, SMART-I.S., storClad, SQI, SuperSwitcher, SuperSwitcher II, Switchtec, SynchroPHY, Total Endurance, Trusted Time, TSHARC, USBCheck, VariSense, VectorBlox, VeriPHY, ViewSpan, WiperLock, XpressConnect, and ZENA are trademarks of Microchip Technology Incorporated in the U.S.A. and other countries. SQTP is a service mark of Microchip Technology Incorporated in the U.S.A. The Adaptec logo, Frequency on Demand, Silicon Storage Technology, and Symmcom are registered trademarks of Microchip Technology Inc. in other countries. GestIC is a registered trademark of Microchip Technology Germany II GmbH & Co. KG, a subsidiary of Microchip Technology Inc., in other countries. All other trademarks mentioned herein are property of their respective companies. 2022, Microchip Technology Incorporated and its subsidiaries. All Rights Reserved.
Quality Management System
For information regarding Microchip’s Quality Management Systems, please visit www.microchip.com/quality.
Worldwide Sales and Service
AMERICAS | ASIA/PACIFIC | ASIA/PACIFIC | EUROPE |
---|
Corporate Office
2355 West Chandler Blvd. Chandler, AZ 85224-6199
Tel: 480-792-7200
Fax: 480-792-7277
Technical Support: www.microchip.com/support Web Address: www.microchip.com Atlanta
Duluth, GA
Tel: 678-957-9614
Fax: 678-957-1455
Austin, TX
Tel: 512-257-3370
Boston Westborough, MA Tel: 774-760-0087
Fax: 774-760-0088
Chicago
Itasca, IL
Tel: 630-285-0071
Fax: 630-285-0075
Dallas
Addison, TX
Tel: 972-818-7423
Fax: 972-818-2924
Detroit
Novi, MI
Tel: 248-848-4000
Houston, TX
Tel: 281-894-5983
Indianapolis Noblesville, IN Tel: 317-773-8323
Fax: 317-773-5453
Tel: 317-536-2380
Los Angeles Mission Viejo, CA Tel: 949-462-9523
Fax: 949-462-9608
Tel: 951-273-7800
Raleigh, NC
Tel: 919-844-7510
New York, NY
Tel: 631-435-6000
San Jose, CA
Tel: 408-735-9110
Tel: 408-436-4270
Canada – Toronto
Tel: 905-695-1980
Fax: 905-695-2078
| Australia – Sydney
Tel: 61-2-9868-6733
China – Beijing
Tel: 86-10-8569-7000
China – Chengdu
Tel: 86-28-8665-5511
China – Chongqing
Tel: 86-23-8980-9588
China – Dongguan
Tel: 86-769-8702-9880
China – Guangzhou
Tel: 86-20-8755-8029
China – Hangzhou
Tel: 86-571-8792-8115
China – Hong Kong SAR
Tel: 852-2943-5100
China – Nanjing
Tel: 86-25-8473-2460
China – Qingdao
Tel: 86-532-8502-7355
China – Shanghai
Tel: 86-21-3326-8000
China – Shenyang
Tel: 86-24-2334-2829
China – Shenzhen
Tel: 86-755-8864-2200
China – Suzhou
Tel: 86-186-6233-1526
China – Wuhan
Tel: 86-27-5980-5300
China – Xian
Tel: 86-29-8833-7252
China – Xiamen
Tel: 86-592-2388138
China – Zhuhai
Tel: 86-756-3210040
| India – Bangalore
Tel: 91-80-3090-4444
India – New Delhi
Tel: 91-11-4160-8631
India – Pune
Tel: 91-20-4121-0141
Japan – Osaka
Tel: 81-6-6152-7160
Japan – Tokyo
Tel: 81-3-6880- 3770
Korea – Daegu
Tel: 82-53-744-4301
Korea – Seoul
Tel: 82-2-554-7200
Malaysia – Kuala Lumpur
Tel: 60-3-7651-7906
Malaysia – Penang
Tel: 60-4-227-8870
Philippines – Manila
Tel: 63-2-634-9065
Singapore
Tel: 65-6334-8870
Taiwan – Hsin Chu
Tel: 886-3-577-8366
Taiwan – Kaohsiung
Tel: 886-7-213-7830
Taiwan – Taipei
Tel: 886-2-2508-8600
Thailand – Bangkok
Tel: 66-2-694-1351
Vietnam – Ho Chi Minh
Tel: 84-28-5448-2100
| Austria – Wels
Tel: 43-7242-2244-39
Fax: 43-7242-2244-393
Denmark – Copenhagen
Tel: 45-4485-5910
Fax: 45-4485-2829
Finland – Espoo
Tel: 358-9-4520-820
France – Paris
Tel: 33-1-69-53-63-20
Fax: 33-1-69-30-90-79
Germany – Garching
Tel: 49-8931-9700
Germany – Haan
Tel: 49-2129-3766400
Germany – Heilbronn
Tel: 49-7131-72400
Germany – Karlsruhe
Tel: 49-721-625370
Germany – Munich
Tel: 49-89-627-144-0
Fax: 49-89-627-144-44
Germany – Rosenheim
Tel: 49-8031-354-560
Israel – Ra’anana
Tel: 972-9-744-7705
Italy – Milan
Tel: 39-0331-742611
Fax: 39-0331-466781
Italy – Padova
Tel: 39-049-7625286
Netherlands – Drunen
Tel: 31-416-690399
Fax: 31-416-690340
Norway – Trondheim
Tel: 47-72884388
Poland – Warsaw
Tel: 48-22-3325737
Romania – Bucharest
Tel: 40-21-407-87-50
Spain – Madrid
Tel: 34-91-708-08-90
Fax: 34-91-708-08-91
Sweden – Gothenberg
Tel: 46-31-704-60-40
Sweden – Stockholm
Tel: 46-8-5090-4654
UK – Wokingham
Tel: 44-118-921-5800
Fax: 44-118-921-5820
References
- {波多野42部无码喷潮在线,18禁美女裸身无遮挡免费网站,国产成人精品一区二三区在线观看,久久精品国产亚洲AⅤ无码}
- Empowering Innovation | Microchip Technology
- Empowering Innovation | Microchip Technology
- Microchip Lightning Support
- Empowering Innovation | Microchip Technology
- Empowering Innovation | Microchip Technology
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>